Migrating virtual disks if the target system is turned off

  1. If installed, remove the front bezel (optional) from the PowerEdge VRTX enclosure.
  2. Power down the server module using the operating system commands or the CMC, and ensure that the server module's power is off.
  3. Turn off the chassis using CMC.
    • NOTE: For information about the chassis shutdown, refer to the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/esmmanuals.
  4. Move the appropriate physical disks from the source system to the target system with a similar Shared PERC 8 controller.
  5. Turn on the target system. The system discovers and automatically imports the detected foreign configuration.