Event ID — 2178

Description The controller battery Learn cycle has timed out.
Severity Warning / Non-critical
Cause and Action Cause: The controller battery must be fully charged before the Learn cycle can begin. The battery may be unable to maintain a full charge causing the Learn cycle to timeout. Additionally, the battery must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the required period of time, then the Learn cycle timeout occurs.

Action: Replace the battery pack as the battery is unable to maintain a full charge.

Related Alert Information Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2100