The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds. All of the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1.
TrapID Description Severity
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Information
131330 Under-Voltage Problem (Lower Critical - going low) Critical
131458 Under-Voltage Problem Cleared Information
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem Cleared Information
65792 Under-Temperature Warning (Lower non-critical, going low) Warning
65920 Under-Temperature Warning Cleared Information
65794 Under-Temperature Problem (Lower Critical - going low) Critical
65922 Under-Temperature Problem Cleared Information
65799 Over-Temperature warning (Upper non-critical, going high) Minor
65927 Over-Temperature warning Cleared Information
65801 Over-Temperature Problem (Upper Critical - going high) Critical
65929 Over-Temperature Problem Cleared Information
131328 Under-Voltage Warning (Lower Non Critical - going low) Warning
131456 Under-Voltage Warning Cleared Information
131330 Under-Voltage Problem (Lower Critical - going low) Critical
131458 Under-Voltage Problem Cleared Information
131335 Over-Voltage Warning (Upper Non Critical - going high) Warning
131463 Over-Voltage Warning Cleared Information
131337 Over-Voltage Problem (Upper Critical - going high) Critical
131465 Over-Voltage Problem Cleared Information
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem Cleared Information
356096 Chassis Intrusion - Physical Security Violation Critical
356224 Chassis Intrusion (Physical Security Violation) Event Cleared Information
262400 Generic Predictive Fan Failure (predictive failure asserted) Minor
262528 Generic Predictive Fan Failure Cleared Information
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Information
264962 Fan redundancy has been degraded Warning
264961 Fan Redundancy Lost Critical
264960 Fan redundancy has returned to Normal Information
2715392 Battery Low (Predictive Failure) Warning
2715520 Battery Low (Predictive Failure) Cleared Information
2715393 Battery Failure Critical
2715521 Battery Failure Cleared Information
487169 CPU Thermal Trip (Over Temperature Shutdown) Critical
487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Information
487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Information
487173 CPU Configuration Error Critical
487301 CPU Configuration Error Cleared Information
487175 CPU Presence (Processor Presence detected) Information
487303 CPU Not Present (Processor Not Present) Critical
487170 CPU BIST (Built In Self Test) Failure Critical
487298 CPU BIST (Built In Self Test) Failure Cleared Information
487176 CPU Disabled (Processor Disabled) Critical
487304 CPU Enabled (Processor Enabled) Information
487178 CPU Throttle (Processor Speed Reduced) Warning
487306 CPU Throttle Cleared (Normal Processor Speed) Information
527106 Power Supply Redundancy Degraded Warning
527105 Power Supply Redundancy Lost Critical
527104 Power Supply Redundancy has returned to Normal Information
552704 Power Supply Inserted Information
552832 Power Supply Removed Warning
552705 Power Supply Failure Critical
552833 Power Supply Failure Cleared Information
552706 Power Supply Warning Warning
552834 Power Supply Warning Cleared Information
552707 Power Supply AC Lost Critical
552835 Power Supply AC Restored Information
789249 Memory Redundancy has been Lost Critical
789248 Memory redundancy has returned to Normal Information
1076994 System Event Log (SEL) Cleared Information
1076996 System Event Log (SEL) Full (Logging Disabled) Critical
2322176 ASR (Automatic System Recovery) Timer Expired Critical
2322177 ASR (Automatic System Recovery) Reset Occurred Critical
2322178 ASR (Automatic System Recovery) Power Down Occurred Critical
2322179 ASR (Automatic System Recovery) Power Cycle Occurred Critical