Status Group

The Status Group objects provide status information about the system and storage.
Table 1. Global System Status
Name globalSystemStatus
Object ID 1.3.6.1.4.1.674.10892.5.2.1.0
Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card.
Syntax ObjectStatusEnum
Access Read-only
Table 2. System LCD Status
Name systemLCDStatus
Object ID 1.3.6.1.4.1.674.10892.5.2.2.0
Description This attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included.
Syntax ObjectStatusEnum
Access Read-only
Table 3. Global Storage Status
Name globalStorageStatus
Object ID 1.3.6.1.4.1.674.10892.5.2.3.0
Description This attribute defines the overall storage status being monitored by the remote access card.
Syntax ObjectStatusEnum
Access Read-only
Table 4. System Power State
Name systemPowerState
Object ID 1.3.6.1.4.1.674.10892.5.2.4.0
Description This attribute defines the power state of the system.
Syntax PowerStateStatusEnum
Access Read-only
Table 5. System Power Up Time
Name systemPowerUpTime
Object ID 1.3.6.1.4.1.674.10892.5.2.5.0
Description This attribute defines the power-up time of the system in seconds.
Syntax Unsigned32BitRange
Access Read-only