Checking the FCB firmware version

Steps

Check the fan control board (FCB) firmware version by executing this IPMI command ipmitool –U server_user_name –P server_user_pass_word –H server_IP –I lanplus raw 0x30 0x12. For example, to check the FCB firmware version v3.09, execute this command:
ipmitool –U root –P calvin –H 10.3.25.127 –I lanplus raw 0x30 0x12 
Response: 01 69 1b 03 09 06 26 00 00 04 ff 00 01 2a 2f ff ff 0f c2 00 00 01 04 01 04 31 c5 11 ff 0f
NOTE:
  • The FCB version will be listed in the 4th and 5th bytes (from the left) of the output. In this output, 03 09 (4th and 5th bytes from the left) indicates the FCB version.
  • The fan table version is listed in the 6th byte of the output. In this output, 06 (6th byte from the left) indicates the fan table version.
  • The node slot is listed in the 10th byte of the output. In this output, 04 (10th byte from the left) indicates the node slot.