Option
--embnic2
Valid Arguments on, off, onnopxe, onwithiscsi
Description

Turns the second embedded NIC on with PXE enabled, off, or on without PXE enabled. This option is only valid for supported systems that have two embedded NICs. If the second NIC is enabled without PXE, it is not found in the boot order. If the second NIC is turned on with PXE, it is placed at the end of the boot order. The onnopxe argument is not supported on all systems. This option can be replicated.

The onwithiscsi argument enables the embedded NIC to boot from the iSCSI server. The embnic2 option can be replicated.

Example:

A:>syscfg --embnic2=onnopxe
embnic2=onnopxe
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.