iDRAC 8/7 v2.30.30.30 User’s Guide

Setting warning threshold for power consumption using web interface

  1. In the iDRAC Web interface, go to Overview > Server > Power/Thermal > Power Monitoring . The Power Monitoring page is displayed.
  2. In the Present Power Reading and Thresholds section, in the Warning Threshold column, enter the value in Watts or BTU/hr. The values must be lower than the Failure Threshold values. The values are rounded off to the nearest value that is divisible by 14. If you enter Watts, the system automatically calculates and displays the BTU/hr value. Similarly, if you enter BTU/hr, the value for Watts is displayed.
  3. Click Apply. The values are configured.