Event ID — 2347

Description
The rebuild failed due to errors on the source physical disk.
Severity
Critical / Failure / Error
Cause and Action
Hardware RAID: Cause and Action

Cause: You are attempting to rebuild data that resides on a defective disk.

Action: Replace the source disk and restore from backup.

Software RAID:

  • Perform a backup with the Verify option.
  • If the file backup fails, try to restore the failed file from a previous backup.
  • When the backup with the Verify option is complete without any errors, delete the Virtual Disk.
  • Recreate a new Virtual Disk with new drives.
  • Restore the data from backup.
Related Alert Information
Clear Alert Number: None

Related Alert Number: 2195, 2346

Local Response Agent (LRA) Number: 2071

SNMP Trap Numbers