FAN Event Messages

FAN0000

Message
Fan arg1 RPM is less than the lower warning threshold.
Arguments
arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan at the next scheduled service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0001

Message
Fan arg1 RPM is less than the lower critical threshold.
Arguments
arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0002

Message
Fan arg1 RPM is greater than the upper warning threshold.
Arguments
arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan at the next scheduled service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0003

Message
Fan arg1 RPM is greater than the upper critical threshold.
Arguments
arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0004

Message
Fan arg1 RPM is outside of range.
Arguments
arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0005

Message
Fan arg1 RPM is within range.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

FAN0006

Message
Fan arg1 is removed.
Arguments
arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
If unintentional, install a fan.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

FAN0007

Message
Fan arg1 was inserted.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

FAN0008

Message
Fan arg1 is present.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0009

Message
Fan arg1 is absent.
Arguments
arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
If unintentional, install a fan.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> is absent. Check Fan.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0010

Message
Fan arg1 is disabled.
Arguments
arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

FAN0011

Message
Fan arg1 is enabled.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

FAN0012

Message
arg1 RPM is less than the lower warning threshold.
Arguments
arg1 = fan name
Detailed Description
The device is not performing optimally. The device may be installed improperly.
Recommended Response Action
Remove and re-install the device at the next scheduled service. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC ✔*           ✔*

FAN0013

Message
arg1 RPM is less than the lower critical threshold.
Arguments
arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0014

Message
arg1 RPM is greater than the upper warning threshold.
Arguments
arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0015

Message
arg1 RPM is greater than the upper critical threshold.
Arguments
arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0016

Message
arg1 RPM is outside of normal operating range.
Arguments
arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0017

Message
arg1 RPM is within normal operating range.
Arguments
arg1 = fan name
Detailed Description
The RPM of the fan identified in the message is functioning correctly.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0018

Message
Enhanced Cooling Mode is not supported for fan arg1 .
Arguments
arg1 = fan number
Detailed Description
Enhanced Cooling Mode is not supported by the type of fan identified in the message.
Recommended Response Action
Replace the fan identified in the message with another fan which supports Enhanced Cooling Mode.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

FAN0019

Message
An incompatibility between operating mode and fan type was corrected for fan arg1 .
Arguments
arg1 = fan number
Detailed Description
An incompatibility between operating mode and fan type was corrected for the fan identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

FAN0020

Message
The arg1 is non-functional.
Arguments
arg1 = fan name
Detailed Description
The fan identified in the message has failed or it is not installed correctly.
Recommended Response Action
Remove and re-install the fan or replace the fan, and open the OMSA Web interface to verify if the fan specified in the message is displayed correctly. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN0021

Message
arg1 is offline.
Arguments
arg1 = fan name
Detailed Description
The fan identified in the meesage is removed. However, the fan may be required for optimal system performance.
Recommended Response Action
Re-install the fan, and open the OMSA Web interface to verify if the fan identified in the message is displayed correctly. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
OMSA Event ID
5303
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN0022

Message
The arg1 sensor has failed, and the last recorded value by the sensor was arg2 RPM.
Arguments
arg1 = sensor name, arg2 = fan speed
Detailed Description
The sensor identified in the message has failed. The sensor may be required for optimal system performance.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN0023

Message
Unable to read the arg1 sensor value.
Arguments
arg1 = sensor name
Detailed Description
The fan sensor identified in the message has failed or the fan has failed.
Recommended Response Action
Do the following: 1) Remove the old fan, install a new fan and power cycle the system to check if the fan is working properly, 2) Replace the system board if the fan sensor has failed. 3) If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5101
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN0024

Message
The arg1 sensor returned to a normal state with a value of arg2 RPM.
Arguments
arg1 = sensor name, arg2 = fan speed
Detailed Description
The sensor identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
OMSA Event ID
5102
OMSA Trap ID
5102
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN0025

Message
The arg1 sensor state has changed to a warning state with a value of arg2 RPM.
Arguments
arg1 = sensor name, arg2 = fan speed
Detailed Description
The fan identified in the message is not functioning correctly. The fan may be installed incorrectly or may be failing.
Recommended Response Action
Remove and re-install the fan, or replace the fan. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5103
OMSA Trap ID
5103
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN0026

Message
The arg1 sensor detected an error with a value of arg2 RPM.
Arguments
arg1 = sensor name, arg2 = fan speed
Detailed Description
The fan sensor identified in the message indicates that the related fan has exceeded critical RPM thresholds..
Recommended Response Action
Remove and re-install the fan, or replace the fan with a new fan. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5104
OMSA Trap ID
5104
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN0027

Message
The arg1 sensor has failed with a value of arg2 RPM.
Arguments
arg1 = sensor name, arg2 = fan speed
Detailed Description
The sensor identified in the message has failed. The sensor may be required for optimal system performance.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults.If the fan sensor has failed, replace the system board. For more information, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5105
OMSA Trap ID
5105
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

FAN1000

Message
arg1 was removed.
Arguments
arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan was removed and the enclosure is no longer functioning in optimal condition..
Recommended Response Action
Re-insert the fan into the enclosure. Contact technical support if the issue persists.
Category
Storage (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
4201
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

FAN1001

Message
arg1 has been inserted.
Arguments
arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan was inserted.
Recommended Response Action
No response action is required.
Category
Storage (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
4203
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

FAN1002

Message
arg1 has failed.
Arguments
arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan has failed and the enclosure is no longer functioning in optimal condition..
Recommended Response Action
Contact technical support.
Category
Storage (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
4201
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

FAN8500

Message
Enhanced Cooling Mode is Enabled
Detailed Description
Enabling Enhanced Cooling Mode will provide increased airflow capability to the blades by increasing the maximum allowable blower speed at the cost of increased power consumption.
Recommended Response Action
No response action is required.
Category
Audit (FAN = Fan Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

FAN8501

Message
Enhanced Cooling Mode is Disabled
Detailed Description
Disabling Enhanced Cooling Mode allows for reduced power consumption by reducing the maximum speed of the blowers while still providing sufficient blade airflow.
Recommended Response Action
No response action is required.
Category
Audit (FAN = Fan Event)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

FAN8502

Message
Unable to detect the blower arg1 because the blower may not be optimally operating.
Arguments
arg1 = blower name
Detailed Description
The current CMC firmware did not detect the blower identified in the message.
Recommended Response Action
Make sure that CMC is using the latest firmware, and then retry the operation.
Category
Audit (FAN = Fan Event)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN8503

Message
The Chassis was turned off because more than two internal fans stopped functioning.
Detailed Description
The Chassis was turned off because more than two Chassis internal fans stopped functioning. The fans with issues are identified in the CMC Hardware (System Event Log) and Chassis Logs.
Recommended Response Action
Make sure that the Chassis internal fans are functioning. At the command line interface (CLI), enter the following command to identify fans that are not functioning: "racadm getsel". Using the CMC Web GUI, select the chassis, click the Logs tab, and then select Hardware Log. Reinsert or replace fans that are not functioning correctly.
Category
Audit (FAN = Fan Event)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN900

Message
The Enhanced Cooling Mode is successfully enabled.
Detailed Description
The Enhanced Cooling Mode is successfully enabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN901

Message
The Enhanced Cooling Mode is successfully disabled.
Detailed Description
The Enhanced Cooling Mode is successfully disabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN902

Message
Cannot enable the Enhanced Cooling Mode because sufficient power is not available.
Detailed Description
The Enhanced Cooling Mode cannot be set because required power is not available.
Recommended Response Action
Add PSUs with higher power capability or remove Chassis components such as I/O Modules orservers until the power requirements have been lowered enough to emable the Enhanced Cooling Mode, and then retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN903

Message
Cannot enable the Enhanced Cooling Mode because an unsupported fan is inserted in the Chassis.
Detailed Description
The Enhanced Cooling Mode cannot be enabled because an unsupported fan is present in the Chassis.
Recommended Response Action
Insert a fan that is supported by the Chassis, and then retry the operation. For a list of fans that are supported by Chassis, see the Chassis Management Controller Users Guide.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN904

Message
Cannot enable the Enhanced Cooling Mode because the Maximum Power Conservation Mode is enabled.
Detailed Description
The Enhanced Cooling Mode cannot be enabled because the Maximum Power Conservation Mode is enabled.
Recommended Response Action
Disable the Maximum Power Conservation Mode, and then retry the operation. To disable the mode by using CMC Web interface, click Chassis Overview > Power > Configuration. To disable the mode using the RACADM utility, run the command "racadm config -g cfgThermal -o cfgThermalEnhancedCoolingMode 0".
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN905

Message
Applying fan configuration settings. This may take several seconds.
Detailed Description
Applying fan configuration settings. This may take several seconds.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN906

Message
Changes are not made to the current settings.
Detailed Description
Changes are not made to the current settings.
Recommended Response Action
Make sure that changes are made to the settings and retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN907

Message
The Enhanced Cooling Mode feature is already enabled.
Detailed Description
The Enhanced Cooling Mode feature is already enabled.
Recommended Response Action
NoneNo response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN908

Message
The Enhanced Cooling Mode feature is already disabled.
Detailed Description
The Enhanced Cooling Mode feature is already disabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN911

Message
The attempt to enable the Enhanced Cooling Mode was not successful.
Detailed Description
The attempt to enable the Enhanced Cooling Mode (ECM) was not successful because ECM is already enabled or Gen3 fans are not present in the Chassis.
Recommended Response Action
Check whether or not the Enhanced Cooling Mode (ECM) is already enabled. Make sure there are Gen3 fans in the Chassis and retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

对此内容评级

准确性
有用性
易理解性
这篇文章对您有帮助吗?
0/3000 characters
  请提供评级(1-5星)。
  请提供评级(1-5星)。
  请提供评级(1-5星)。
  请选择这篇文章是否有帮助。
  注释中不得包含以下特殊字符:<>()\