Skip to main content
PowerEdge R730xd image

PowerEdge R730xd

PowerEdge R730xd

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 338 shown
338 out of 338 shown

The article describes updating Dell PowerEdge server firmware through Integrated Dell Remote Access Controller (iDRAC) 7, 8, 9, or 10. It details downloading the firmware image, logging in to the iDRAC web interface, uploading the image for installation, and managing pending updates.
Updated:  September 30, 2026 ID: 000134013

This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
Updated:  September 17, 2026 ID: 000127944

H355 JBOD Target ID 0 Missing After PD Replacement
Updated:  October 09, 2026 ID: 000518557

Certain Dell qualified Seagate Exos X24 SAS drives have undergone a hardware revision. As a result, replacement drives may ship with firmware revisions ending in A (SWSA, SYSA, or SUSA), while existing drives may be running firmware revisions ending in 9 (SWS9, SYS9, or SUS9). This behavior is expected and supported. The firmware difference reflects a hardware revision and does not indicate a problem with the drive, a firmware mismatch, or a requirement to update existing drives. Key Point: Customers do not need to update existing SxS9 drives to SxSA firmware. SxS9 firmware remains the correct firmware family for original hardware revisions.
Updated:  October 09, 2026 ID: 000502414

Hardware Diagnostics are embedded tools installed in the pre-OPERATING SYSTEM of your server to check hardware is working as designed.
Updated:  October 07, 2026 ID: 000132726

Frequently Asked Questions (FAQ) about Physical Drives replacement in RAID Server and MD Arrays
Updated:  October 07, 2026 ID: 000139367

Toshiba AL15SE HDDs may enter a Drive Not Ready (DNR) state and report repeated seek retries associated with sense codes 04-4C-91, 04-4C-95, 04-4C-E0, or 04-44-82.
Updated:  October 07, 2026 ID: 000495316

This article explains what a predictive drive failure (error code PDR16) means, why it occurs, and provides step-by-step instructions to troubleshoot and resolve the issue. It covers recommended actions such as backing up data, updating firmware, and replacing the disk if necessary to ensure storage health and prevent data loss.
Updated:  October 07, 2026 ID: 000126418

Dell OpenManage Enterprise (OME) uses a multi-step process to discover and onboard servers through iDRAC. The discovery process begins with a basic network reachability check (ICMP ping) followed by protocol-level communication (Redfish or WS-Man). If any step in this chain fails, the discovery will not succeed.
Updated:  October 07, 2026 ID: 000507806

Learn how to create a bootable USB with Rufus to update Dell PowerEdge servers and format the drive. Follow the step-by-step instructions to prepare and create a bootable USB media.
Updated:  October 06, 2026 ID: 000141551

This article explains how to access and use Jobs and Logs in Dell Repository Manager (DRM) for troubleshooting purposes. It covers the Jobs page, where every DRM action is recorded with a timestamp, the location of the drmservice-0.log file on both Windows and Linux, and how to use the built-in Save and Email Logs feature to export a zipped copy of all logs directly from the DRM UI.
Updated:  October 06, 2026 ID: 000183933

Summary: Steps to enable and collect debug logs from OpenManage Enterprise 3.9 and later for diagnostic purposes.
Updated:  October 05, 2026 ID: 000212597

Micron 5x00 Series SSDs may experience read/write performance degradation after reaching approximately 65,535 power-on hours (POH), which equates to roughly 7.5 years of operation. This issue affects performance only and does not result in data loss or drive failure.
Updated:  October 02, 2026 ID: 000464492

This article describes how to enable, use, and disable Field Service Debug (FSD) mode in OpenManage Enterprise for advanced troubleshooting under Dell Support guidance. FSD provides SSH and SCP access to the appliance and must only be used in conjunction with an active Dell Support engagement. Verbiage may differ on pre-OME 4.7 versions.
Updated:  October 02, 2026 ID: 000212619

Dell PM1735a Non-Volatile Memory Express (NVMe) drive failing in PowerEdge servers.
Updated:  October 02, 2026 ID: 000481601

This article provides links to product documentation, troubleshooting KB articles, and videos for PowerEdge Rack and Tower servers and Dell systems management tools. Use the expandable sections to find Installation and Service Manuals, iDRAC, OME, and other management product guides.
Updated:  October 01, 2026 ID: 000203864

This article talks about the Intel Cluster on Die technology as it pertains to VMware ESXi.
Updated:  September 23, 2026 ID: 000147278

When firmware updates are applied to Dell PowerEdge servers outside of the OpenManage Enterprise (OME) workflow, the OME inventory may not reflect the updated versions. Running a manual inventory task or re-onboarding the device in OME will force a re-detection and resolve the discrepancy.
Updated:  September 21, 2026 ID: 000510650

This article explains how to disable the third-party PCIe Card default cooling response on PowerEdge 13G Servers.
Updated:  September 21, 2026 ID: 000135682

Find answers and resources to get started or do more from your MyService360 dashboard with enterprise services data analytics and visualizations.
Updated:  September 18, 2026 ID: 000124666

This article explains how to use the RACADM systemerase command to erase data and reset components on a Dell PowerEdge server with iDRAC9, including command syntax, component list, and a lab walkthrough.
Updated:  September 17, 2026 ID: 000460243

The iDRAC provides a web interface and a command-line interface that allows administrators to perform remote management tasks.
Updated:  September 14, 2026 ID: 000179517

Integrated Remote Access Controller (iDRAC10) logs SRV016 reporting a timeout exporting logs and log collection, caused by checks during TTY log gathering, on firmware 1.30.50.xx.
Updated:  September 14, 2026 ID: 000495521

This article shows how to do network card testing using the Support Live Image (SLI).
Updated:  September 10, 2026 ID: 000120458

This article explains how to fix a problem when responding to a Critical error by pressing "C" then "Y" not entering into HII in UEFI mode.
Updated:  September 10, 2026 ID: 000067589

This article identifies which Operating System (OS) files the iDRAC Service Module (iSM) replicates the Lifecycle Controller (LC) logs to.
Updated:  September 10, 2026 ID: 000064204

This article provides information about how to create a bootable USB drive from and OS ISO file for manual installation.
Updated:  September 10, 2026 ID: 000334285

When working on internal components of a Dell computer, follow the safety precautions that are provided in this article to avoid any harm on the hardware.
Updated:  September 10, 2026 ID: 000175301

The Dell Nautilus Firmware Update Utility is flexible and simple to use as it contains all the latest, relevant firmware updates for hard drives in your Dell server.
Updated:  September 10, 2026 ID: 000141811

Dell OS and Applications Solutions on Dell TechCenter - Project Sputnik, Microsoft Windows, Red Hat Linux, SUSE, Ubuntu, and more
Updated:  September 10, 2026 ID: 000145895