Skip to main content
PowerEdge R7725xd image

PowerEdge R7725xd

PowerEdge R7725xd

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 344 shown
344 out of 344 shown

This article explains how to perform a driver or firmware update directly from the operating system (OS) using a Dell Update Packages (DUP).
Updated:  September 04, 2026 ID: 000130467

This article explains how to find supported memory configuration for your PowerEdge server.
Updated:  September 02, 2026 ID: 000135681

Dell PowerEdge Server remediation is available for Nuvoton NPCT7xx Trusted Platform Module (TPM) 2.0 firmware versions that could be exploited by malicious users to compromise the affected system.
Updated:  September 08, 2026 ID: 000477639

This article shows How To determine why a virtual machine powered off or rebooted by reviewing log files and host details to identify guest shutdowns, user or API requests, HA resets or system faults.
Updated:  September 07, 2026 ID: 000205778

Dell iDRAC9 and iDRAC10 remediations for a Command Injection security vulnerability that could be exploited by malicious users to compromise the affected system.
Updated:  September 03, 2026 ID: 000504998

To replace a CMOS battery, remove the air shroud, disconnect and remove any expansion cards, locate the battery socket, and carefully pry out the CMOS battery. After installing a new CMOS battery, you must reinstall the expansion cards, install the air shroud, and restore the BIOS settings, ensuring the battery is operating properly and the correct data and time are set in the System Setup.
Updated:  September 02, 2026 ID: 000234357

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  September 02, 2026 ID: 000227912

This article explains how to use the Import Server License feature to import an iDRAC license from the Lifecycle Controller UI.
Updated:  September 02, 2026 ID: 000139682

Frequently Asked Questions (FAQ) about Physical Drives replacement in RAID Server and MD Arrays
Updated:  September 02, 2026 ID: 000139367

This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Updated:  September 02, 2026 ID: 000136481

The article describes updating Dell PowerEdge server firmware through Integrated Dell Remote Access Controller (iDRAC) 7, 8, 9, or 10. It details downloading the firmware image, logging in to the iDRAC web interface, uploading the image for installation, and managing pending updates.
Updated:  September 02, 2026 ID: 000134013

Explore various RAID levels - RAID 0, 1, 5, 6, and 10 - implemented in Dell PowerEdge servers. Learn about their configurations, benefits, and how they impact data redundancy and performance.
Updated:  September 02, 2026 ID: 000128635

PowerEdge 17th Generation Servers with Delta Power Supplies may not show correctly in iDRAC UI and SEL logging after AC cycle.
Updated:  September 01, 2026 ID: 000471893

In some situations Dell Technical Support may request evidence to perform a more assertive diagnosis, this article illustrates how to attach files to your service request through the Dell support portal.
Updated:  September 01, 2026 ID: 000194683

This article explains the requirements to deploy VMware ESXi 9 virtual machines with 4Kn end‑to‑end (E2E) storage when using Dell PowerEdge PERC12 (H965) and newer controllers. It also covers how to identify when ESXi is using 4Kn software emulation (SWE) instead of true 4Kn E2E, and what conditions prevent E2E.
Updated:  September 01, 2026 ID: 000467282

This page explains the difference between drivers and firmware and how to update them on Dell PowerEdge Servers using different methods.
Updated:  August 31, 2026 ID: 000128194

Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Updated:  August 31, 2026 ID: 000221846

Installation of Ubuntu 26.04 on AMD based 17G servers produces a kernel panic. Ubuntu 26.04 is not supported on AMD based 17G servers with CXL memory until December. Ubuntu 26.04 is supported with no CXL memory installed.
Updated:  August 31, 2026 ID: 000502446

Micron 5x00 Series SSDs may experience read/write performance degradation after reaching approximately 65,535 power-on hours (POH), which equates to roughly 7.5 years of operation. This issue affects performance only and does not result in data loss or drive failure.
Updated:  August 31, 2026 ID: 000464492

This article explains how to use the RACADM systemerase command to securely erase data and reset components on a Dell PowerEdge server with iDRAC9. It includes the full component list, command syntax, server behavior during the erase process, and a step-by-step lab walkthrough demonstrating Lifecycle Controller data erasure via SSH.
Updated:  August 31, 2026 ID: 000460243

Samsung PM9D3a and PM9D5a NVMe SSDs used in PowerEdge servers lack support for the Security Protocol and Data Model (SPDM), causing SPDM‑related features to fail.
Updated:  August 27, 2026 ID: 000459691

Dell PM1735a Non-Volatile Memory Express (NVMe) drive failing in PowerEdge servers.
Updated:  August 27, 2026 ID: 000481601

A BIOS update launched through iDRAC fails, showing the message "Failed to parse Update XML or empty." The failure is caused by an unreadable or missing package.xml, disabled Lifecycle Controller, stuck jobs, or iDRAC XML parser issues.
Updated:  August 26, 2026 ID: 000502513

The NVRM message "NVRM: gpuClearFbhubPoisonIntrForBug2924523_GA100: FBHUB Interrupt detected. Clearing it" on systems equipped with NVIDIA A100 or H200 NVL GPUs running NVIDIA Driver may be observed in the Linux kernel log such as dmesg.
Updated:  August 26, 2026 ID: 000491664

Dell Micron 9550 E3.S Non-Volatile Memory Express (NVMe) solid state drives (SSDs) may report "unknown" status in iDRAC during warm reboot stress testing without an Operating System (OS) installed.
Updated:  August 26, 2026 ID: 000365651

This article is a step-by-step guide to configure 2x100G links of the Broadcom BCM57508-N2100D and BCM57508-P2100D as a single 200G link.
Updated:  August 25, 2026 ID: 000450441

This article explains Dell’s 17th Generation (17G) transition from Dell‑custom Ethernet network interface cards (NICs) to industry‑standard NICs, detailing how this change aligns with industry practices while preserving Dell validation, life cycle management, and enterprise support, with standardized iDRAC‑based management.
Updated:  August 25, 2026 ID: 000449389

Understanding Cold Redundancy: Feature Overview and Comparisons with Hot Spare and Redundancy Policies
Updated:  August 25, 2026 ID: 000447877

This article explains how to address the error "The system has found a problem on your machine and cannot continue. Unable to restore the system configuration. A security violation was detected". Purple screen / Purple screen of Death (PSOD)
Updated:  August 24, 2026 ID: 000436068

The Hyper-V virtual machine enters recovery mode after enabling nested virtualization on 17G Windows Server 2025
Updated:  August 24, 2026 ID: 000447388