Articles
Tooltip title
Select a category and then related component(s) to find articles about specific hardware and software.
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 719 shown
719 out of 719 shown
The Integrated Dell Remote Access Controller 9 (iDRAC9) provides comprehensive, embedded management across the PowerEdge family of servers. IDRAC9 automation that lets your organization grow, and security that ensures peace of mind. It is a key technology in the OpenManage portfolio. Users can build a management solution that matches your needs, and by leveraging iDRAC, ensures optimal server management.
Updated: October 01, 2026
ID: 000178016
The article describes updating Dell PowerEdge server firmware through Integrated Dell Remote Access Controller (iDRAC) 7, 8, 9, or 10. It details downloading the firmware image, logging in to the iDRAC web interface, uploading the image for installation, and managing pending updates.
Updated: September 30, 2026
ID: 000134013
This article provides step-by-step instructions for enabling debug logging in OpenManage Enterprise via the Virtual Machine Console TUI, reproducing the issue, and generating a log bundle from the web console for diagnostic purposes.
Updated: October 16, 2026
ID: 000212597
This article explains how to use iDRAC Direct to manage your PowerEdge server.
Updated: October 16, 2026
ID: 000130077
This article explains the procedure to open a Service Request (SR) using the Dell support page.
Get help fast for your Dell device. No more waiting on hold. No more tech headaches.
Dell makes it simple to fix problems, schedule repairs, or get support—right from your device or our support website.
Updated: October 15, 2026
ID: 000132371
Retail Devices vs. OEM: This article describes a possible reason why users may be unable to update their PCI adapter or view its status using the IDRAC or Lifecycle Controller.
Updated: October 14, 2026
ID: 000207694
Attempting to activate Windows Server results in activation failure with error code 0xC004C008 or 0xC004C020. These errors indicate that the activation limit of the specified product key has been reached.
Updated: October 13, 2026
ID: 000139763
Dell PowerEdge Server remediation is available for Nuvoton NPCT7xx Trusted Platform Module (TPM) 2.0 firmware versions that could be exploited by malicious users to compromise the affected system.
Updated: October 13, 2026
ID: 000502288
Dell PowerEdge Server remediation is available for an OpenSSL Vulnerability that could be exploited by malicious users to compromise the affected systems.
Updated: October 13, 2026
ID: 000458870
Dell PowerEdge Server remediation is available for Nuvoton NPCT7xx Trusted Platform Module (TPM) 2.0 firmware versions that could be exploited by malicious users to compromise the affected system.
Updated: October 13, 2026
ID: 000477639
This article provides information about the VLT0204 error code and guidance.
Updated: October 13, 2026
ID: 000403266
Dell PowerEdge Server remediation is available for 2026.3 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
Updated: October 13, 2026
ID: 000505000
Dell PowerEdge Server remediation is available for 2026.1 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
Updated: October 13, 2026
ID: 000426743
Dell PowerEdge Server remediation is available for a Tianocore EDK2 Vulnerability that could be exploited by malicious users to compromise the affected systems.
Updated: October 13, 2026
ID: 000440351
This document highlights minimum, recommended, and latest code versions for Dell Technologies PowerEdge products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: October 12, 2026
ID: 000227230
This article provides information about how to disable C-States and C1E on a PowerEdge Server.
Updated: October 12, 2026
ID: 000135039
H355 JBOD Target ID 0 Missing After PD Replacement
Updated: October 09, 2026
ID: 000518557
Certain Dell qualified Seagate Exos X24 SAS drives have undergone a hardware revision. As a result, replacement drives may ship with firmware revisions ending in A (SWSA, SYSA, or SUSA), while existing drives may be running firmware revisions ending in 9 (SWS9, SYS9, or SUS9).
This behavior is expected and supported. The firmware difference reflects a hardware revision and does not indicate a problem with the drive, a firmware mismatch, or a requirement to update existing drives.
Key Point: Customers do not need to update existing SxS9 drives to SxSA firmware. SxS9 firmware remains the correct firmware family for original hardware revisions.
Updated: October 09, 2026
ID: 000502414
A Kioxia PM5 (previously seen as a Toshiba PM5) series SAS drive running firmware B020 or B31C may not be detected by the storage controller on reboot of a host.
Updated: October 08, 2026
ID: 000187532
Hardware Diagnostics are embedded tools installed in the pre-OPERATING SYSTEM of your server to check hardware is working as designed.
Updated: October 07, 2026
ID: 000132726
Frequently Asked Questions (FAQ) about Physical Drives replacement in RAID Server and MD Arrays
Updated: October 07, 2026
ID: 000139367
Toshiba AL15SE HDDs may enter a Drive Not Ready (DNR) state and report repeated seek retries associated with sense codes 04-4C-91, 04-4C-95, 04-4C-E0, or 04-44-82.
Updated: October 07, 2026
ID: 000495316
PowerEdge 15G, 16G, and 17G Servers
Do not upgrade to Nuvoton NPCT7xx TPM firmware version 7.2.4.0 without first reviewing your TPM key usage.
Firmware version 7.2.4.0 introduces a change to the ECC key derivation process that renders externally stored ECC child keys created on version 7.2.3.1 or earlier unusable. Environments that rely on these keys must unbind and re-provision them before performing the firmware update, or key access may be permanently lost.
RSA keys are not affected.
Due to the risk of ECC key incompatibility, the TPM firmware DUP packages have been removed from the platform catalog to prevent unintended upgrades. Administrators should complete any required ECC key remediation before updating TPM firmware.
Updated: October 07, 2026
ID: 000489182
This article explains what a predictive drive failure (error code PDR16) means, why it occurs, and provides step-by-step instructions to troubleshoot and resolve the issue. It covers recommended actions such as backing up data, updating firmware, and replacing the disk if necessary to ensure storage health and prevent data loss.
Updated: October 07, 2026
ID: 000126418
Dell OpenManage Enterprise (OME) uses a multi-step process to discover and onboard servers through iDRAC. The discovery process begins with a basic network reachability check (ICMP ping) followed by protocol-level communication (Redfish or WS-Man). If any step in this chain fails, the discovery will not succeed.
Updated: October 07, 2026
ID: 000507806
Learn how to create a bootable USB with Rufus to update Dell PowerEdge servers and format the drive. Follow the step-by-step instructions to prepare and create a bootable USB media.
Updated: October 06, 2026
ID: 000141551
This article explains how to access and use Jobs and Logs in Dell Repository Manager (DRM) for troubleshooting purposes. It covers the Jobs page, where every DRM action is recorded with a timestamp, the location of the drmservice-0.log file on both Windows and Linux, and how to use the built-in Save and Email Logs feature to export a zipped copy of all logs directly from the DRM UI.
Updated: October 06, 2026
ID: 000183933
Systems Management How to Video that Covers the Process of Installing and Registering the OpenManage Enterprise Integration for VMware vCenter (OMEVV) plug-in.
Updated: October 06, 2026
ID: 000216491
Micron 5x00 Series SSDs may experience read/write performance degradation after reaching approximately 65,535 power-on hours (POH), which equates to roughly 7.5 years of operation. This issue affects performance only and does not result in data loss or drive failure.
Updated: October 02, 2026
ID: 000464492
This article describes how to enable, use, and disable Field Service Debug (FSD) mode in OpenManage Enterprise for advanced troubleshooting under Dell Support guidance. FSD provides SSH and SCP access to the appliance and must only be used in conjunction with an active Dell Support engagement. Verbiage may differ on pre-OME 4.7 versions.
Updated: October 02, 2026