Skip to main content
PowerEdge XR4000z image

PowerEdge XR4000z

PowerEdge XR4000z

Articles

Select a category and then a related component to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 253 shown
253 out of 253 shown

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  June 12, 2026 ID: 000227983

This article provides links to download Dell trial 30 and 90-day evaluation license collection including iDRAC Enterprise, iDRAC Datacenter, Chassis Management Consoles (CMC) Enterprise, OpenManage Enterprise, and OpenManage Integration.
Updated:  June 10, 2026 ID: 000176472

This article provides information about how to use the LCC to deploy a supported OS.
Updated:  June 13, 2026 ID: 000334676

This article shows how to use and set up the virtual media function of Integrated Dell Remote Access Controller (iDRAC) 6, 7, 8, or 9.
Updated:  June 12, 2026 ID: 000124001

PowerEdge Server catalogs are an aggregation of all bundles and Dell Update Packages' metadata used by Dell OpenManage Repository Manager, Dell OpenManage Enterprise, and other tools for listing the current versions of software and firmware for respective servers and devices.
Updated:  June 12, 2026 ID: 000132986

PowerEdge 17th Generation Servers with Delta Power Supplies may not show correctly in iDRAC UI and SEL logging after AC cycle.
Updated:  June 05, 2026 ID: 000471893

Dell PowerEdge servers with common design components are grouped into generations, for example PowerEdge 17th generation servers, 16th generation, 15th generation, or 14th generation. This article provides general guidance for PowerEdge server model naming convention to identify the generation and common components. This article also lists all PowerEdge servers by model including type, CPU, generation, and remote management components.
Updated:  June 03, 2026 ID: 000137343

This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
Updated:  June 02, 2026 ID: 000143247

This article provides some checklist to prevent unnecessary components replacement on DC power supply implementation.
Updated:  May 27, 2026 ID: 000221234

This article explains how some Dell server platforms offer the optional security bezel with dust filter. The air filter bezel can be configured as Countdown Mode or Active Sensing Mode. After a certain period of lifetime, the IDRAC may report alert events and require the dust filter to be replaced.
Updated:  May 25, 2026 ID: 000217749

NVIDIA has updated the signing certificate for its UEFI network driver from Microsoft UEFI CA 2011 to Microsoft UEFI CA 2023. PowerEdge 17G platforms already trust the CA 2023 certificate, but 15G/16G and earlier servers require a BIOS update released in December 2025. Systems without this updated certificate support may fail to initialize the NIC UEFI driver when Secure Boot is enabled.
Updated:  May 24, 2026 ID: 000420051

PowerEdge servers do not support operating system installation, or boot from direct CPU‑attached NVMe SSD drives if the metadata format size is not set to 0.
Updated:  May 24, 2026 ID: 000417881

This article provides information about the LIC008 error seen when importing the IDRAC License.
Updated:  May 23, 2026 ID: 000353269

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
Updated:  May 23, 2026 ID: 000311902

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

OpenManage Enterprise integration for VMware vCenter may fail to Unmanage hosts with error "UNMANAGE_REMOVE_MEL_FAILURE"
Updated:  May 21, 2026 ID: 000233873

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

VMware vCenter registration may fail in OMEVV 1.3 with a custom certificate chain installed in OpenManage Enterprise (OME) or vCenter.
Updated:  May 20, 2026 ID: 000223404

On an ESXi host, if the Flow Control setting on the BCM5720 is modified without a cable inserted, the network interface card (NIC) may fail to establish a link when a cable is later inserted. The issue does not occur if the setting is modified with a cable inserted in the NIC port.
Updated:  May 20, 2026 ID: 000222793

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated:  May 20, 2026 ID: 000222201

In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Updated:  May 19, 2026 ID: 000221490

When in a SNAPI enabled configuration, the Dell Mellanox Ethernet and InfiniBand NICs may display 0000:0000:0000:0000 as the virtual node GUID for the second partition.
Updated:  May 19, 2026 ID: 000221406

PowerEdge Servers installed with Intel Ethernet 100G 2P E810-2C Adapter have only one port being enumerated under device settings.
Updated:  May 19, 2026 ID: 000221187

Firmware upgrades to Broadcom network devices may fail with a "libpci.so: Cannot open" error when run from a Smart Bootable ISO image created with Dell Repository Manager 3.x.
Updated:  May 19, 2026 ID: 000221180

If "Automatically restart" under System Failure is disabled inside Windows Server 2019 and 2022, a manual reboot is needed after a bug check or crash, but the system is rebooting automatically.
Updated:  May 19, 2026 ID: 000220429

Increased fan spinning noise. PowerEdge 15G servers equipped with a Dell Intel X710 Open Compute Project (OCP3) Network card after upgrading the Integrated Dell Remote Access Controller (iDRAC) firmware to version 7.00.30.00
Updated:  May 19, 2026 ID: 000219529