Dell Online Rack UPS

intel® core™ processors
 
Call Dell
1-800-999-3355

Keep the power on, even during an outage.

Get maximum protection from common power problems with an easy-to-install, easy-to-manage Dell™ UPS sized for 2700W–10KW rack loads in data centers.

 
Select
 
 

 

Dell Online Rack UPS - Easy to choose, install and afford

Easy to choose, install and afford

With precise power ratings, tool-free installation and a design that can help support energy efficiency, there’s a Dell UPS system that’s ideal for your environment. Dell UPS combines leading power regulation technology with network support, environmental monitoring and virtualization integration to offer a comprehensive IT solution.

Customized power sizing

Dell UPS systems are configured and sized in watts, enabling you to select a UPS that’s compatible with the actual power draw of your environment.

Simplified installation

Get up and running quickly with Dell ReadyRails tool-less mounting kits, which install in your rack without tools in less than 10 seconds.

Up to 97% percent efficiency

Enjoy high levels of energy efficiency with a UPS designed to use less power, dissipate less heat and help reduce cooling costs.
Dell Online Rack UPS - Integrates seamlessly with your Dell equipment

Integrates seamlessly with your Dell equipment

Designed to protect your data in the event of power loss, a Dell UPS can integrate easily with your existing Dell network and server infrastructures.
  • Matching design
    A bold, clean design can coordinate with the appearance of your Dell servers.
  • Large on-unit display
    Change control settings easily with the large, backlit LCD control panel, offering the same color-coded system as Dell servers.
  • Region-appropriate sockets
    Customized sockets and back plates help ensure compatibility with your region’s power requirements.
  • Extended battery life
    Run for up to 19 minutes with the available External Battery Module (EBM)*.
  • Easy selection
    Choose the right UPS for your needs with the configurator on www.dellups.com
Dell Online Rack UPS - Simple to manage in any environment

Simple to manage in any environment

Monitor your power consumption, power events, available battery runtime, alarm conditions and more with free software and a range of control options.
  • Multi-UPS Management Console (MUMC) Software
    Monitor and configure multiple UPS systems across your network using a single interface.
  • UPS Local Node Manager (ULNM) software
    Tailor the shutdown of devices in a single-UPS environment using a simple online interface.
  • Virtualization integration
    Integrate with virtualized server environments, including popular platforms from VMware®, Microsoft®, Citrix®, OpenSource and Red Hat®.

Chassis

  • 2700W Telco:

    120V:
    Power Rating: 2700 Watts
    Runtimes: 5 mins @ full load, 14 mins @ ½ load
    Input Voltages: 110, 120, 127 VAC
    Output Voltages: 110, 120, 127 VAC
    Input Connection: (1) NEMA L5-30P
    Output Receptacles: NEMA L5-20R(X1), NEMA 5-20R(X2), IEC-60320 C13(X2)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 17” – 79.3lbs
    Heat Dissipation in Normal Mode BTU/hr: 461

    208V:
    Power Rating: 2700 Watts
    Runtimes: 5 mins @ full load, 14 mins @ ½ load
    Input Voltages: 208 VAC
    Output Voltages: 208 VAC
    Input Connection: (1) NEMA L6-20P
    Output Receptacles: NEMA L6-20R(X1), NEMA L6-30R(X2),
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 17” – 79.3lbs
    Heat Dissipation in Normal Mode BTU/hr: 461

    230V:

    Power Rating: 2700 Watts
    Runtimes: 5 mins @ full load, 14 mins @ ½ load
    Input Voltages: 220, 230 240 VAC
    Output Voltages: 220, 230 240 VAC
    Input Connection:
    (1) CEE 7/7 16 Amp
    (1) BS 1363 15 Amp
    (1) GB2009.1 16 Amp
    (2) IEC-60320 C19 to IEC-60320 C20
    Output Receptacles: IEC-60320 C13(X8), IEC-60320 C19(X1)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 17” – 79.3lbs
    Heat Dissipation in Normal Mode BTU/hr: 461


    3750W:

    208V:
    Power Rating: 3750 Watts
    Runtimes: 5 mins @ full load, 21 mins @ ½ load
    Input Voltages: 200, 208 VAC
    Output Voltages: 200, 208 VAC
    Input Connection: (1) NEMA L6-30P
    Output Receptacles: NEMA L6-30R(X1), NEMA L6-20R(X2), IEC-60320 C19(X2)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 31.1” – 144lbs
    Heat Dissipation in Normal Mode BTU/hr: 640

    230V:
    Power Rating: 3750 Watts
    Runtimes: 5 mins @ full load, 21 mins @ ½ load
    Input Voltages: 220, 230, 240 VAC
    Output Voltages: 220, 230, 240 VAC
    Input Connection: Hardwired
    Output Receptacles: IEC-60320 C13(X8), IEC-60320 C19(X2)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 31.1” – 144lbs
    Heat Dissipation in Normal Mode BTU/hr: 640


    4200W:

    208V:
    Power Rating: 4200 Watts
    Runtimes: 5 mins @ full load, 16 mins @ ½ load
    Input Voltages: 200, 208 VAC
    Output Voltages: 200, 208 VAC
    Input Connection: Hardwired
    Output Receptacles: NEMA L6-30R(X1), NEMA L6-20R(X2), IEC-60320 C19(X4)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 31.1” – 144lbs
    Heat Dissipation in Normal Mode BTU/hr: 717

    230V:
    Power Rating: 4200 Watts
    Runtimes: 5 mins @ full load, 16 mins @ ½ load
    Input Voltages: 200, 208, 220, 230, 240 VAC
    Output Voltages: 200, 208, 220, 230, 240 VAC
    Input Connection: Hardwired
    Output Receptacles: IEC-60320 C13(X6), IEC-60320 C19(X4)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 31.1” – 144lbs
    Heat Dissipation in Normal Mode BTU/hr: 717


    5600W OL:

    208V:
    Power Rating: 5600 Watts
    Runtimes: 5 mins @ full load, 15 mins @ ½ load
    Input Voltages: 200, 208 VAC
    Output Voltages: 200, 208 VAC
    Input Connection: Hardwired
    Output Receptacles: NEMA L6-30R(X2), IEC-60320 C19(X4)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 31.1” – 141lbs
    Heat Dissipation in Normal Mode BTU/hr: 989

    230V:
    Power Rating: 5600 Watts
    Runtimes: 5 mins @ full load, 15 mins @ ½ load
    Input Voltages: 220, 230, 240 VAC
    Output Voltages: 220, 230, 240 VAC
    Input Connection: Hardwired
    Output Receptacles: IEC-60320 C13(X6), IEC-60320 C19(X4)
    Physical Specs (w x h x d – wt): 17.2” x 6.75” x 31.1” – 141lbs
    Heat Dissipation in Normal Mode BTU/hr: 989


    10kW OL:

    208V
    Power rating: 10 kW
    Runtimes: 5 minutes at full load, 13 minutes at half load
    Input Voltages: 200, 208 VAC
    Output Voltages: 200, 208 VAC
    Input Connection: Hardwired
    Output Receptacles: (2) L6-30R and (4) C19
    Physical Specs (w x h x d – wt): 17.2 x 8.4 x 32.4 inches – 242 lbs.
    Heat Dissipation in Normal Mode BTU/hr: 1420

    230V
    Power rating: 10 kW
    Runtimes: 5 minutes at full load, 13 minutes at half load
    Input Voltages: 200, 208, 220, 230, 240 VAC
    Output Voltages: 200, 208, 220, 230, 240 VAC
    Input Connection: Hardwired - North America / International
    Output Receptacles: (8) C19
    Physical Specs (w x h x d – wt): 17.2 x 8.4 x 32.4 inches – 242 lbs.
    Heat Dissipation in Normal Mode BTU/hr: 1420

    230V
    Power rating: 10 kW
    Runtimes: 5 minutes at full load, 13 minutes at half load
    Input Voltages: 200, 208, 220, 230, 240 VAC
    Output Voltages: 200, 208, 220, 230, 240 VAC
    Input Connection: Hardwired
    Output Receptacles: (2) IEC 309 32A and (2) C19
    Physical Specs (w x h x d – wt): 17.2 x 8.4 x 32.4 inches – 242 lbs.
    Heat Dissipation in Normal Mode BTU/hr: 1420
External Battery Module

Dell uninterruptible power supplies (UPS) provide battery backup power to ride through brief outages or to allow enough time for graceful shutdown of connected servers. This backup runtime can be extended with the use of optional External Battery Modules (EBMs). For example, an EBM extends battery runtime from 5 minutes to 11 minutes for a 4200W UPS, to 14 minutes for a 3750W UPS, and to 19 minutes for a 1920W, 2700W or 5600W UPS, assuming a 100 percent loaded UPS.*

Network Management Card

The Dell Network Management Card (NMC) hot plugs into the Dell UPS, connecting it to the IT network. For users with an SNMP-based infrastructure management system, the NMC also provides SNMP traps of power alarms and events.

UPS user settings can be made either through the NMC web interface (accessed through a web browser with the NMC IP address) or through the Dell UPS management software. Changes made in either location will be synchronized with the other to avoid conflicts.

The network management card provides additional functionality over USB:
  • Full support for virtualized IT infrastructures
  • Ability to send SMTP email alerts directly from the NMC without relying on UPS management software
  • SNMP network alerts (supporting the RFC-1628 industry standard Management Information Bases (MIBs))
  • Ability to schedule power up and power down of the UPS and associated server equipment
  • Simplified ability to manage multiple UPS installations, including supervision across WAN (for example, for satellite offices)
The NMC is a prerequisite for virtualized IT infrastructures because of the native limitations of USB and hypervisors.

Environmental Monitoring Probe

The optional Dell Environmental Monitoring Probe (EMP) enables you to remotely monitor the temperature, humidity and status of two contact devices through a standard web browser, providing a wide range of environmental and rack-level monitoring capabilities. These status readings can create user alerts and invoke graceful server shutdown at predetermined threshold limits.

Threshold settings and actions based on these thresholds can be set either in the Dell UPS management software or through the UPS NMC interface. Variables are reported directly into the UPS software and (optionally) across the network as SNMP traps.

The EMP is hot installable and can be positioned anywhere within a 19” rack or any flat surface in the IT environment. The EMP can be used with any Dell UPS equipped with a Dell NMC. A maximum of one (1) EMP can be connected to each Dell UPS.

Power Cable Kits

Power cable kits simplify installation for hardwired UPS models by converting them into input (mains) power cable units that can be placed in proximity to an appropriate power source and moved to a new location without the services of an electrician. Cable kits are available for most hardwired UPS models, and must be installed by qualified personnel.

Metered and Managed PDUs

Combined with Dell Power Distribution Units (PDUs), Dell UPS hardware enables you to deploy a Dell power protection and distribution scheme for a flexible, effective power strategy. Dell UPS hardware provides supervision of Dell metered and managed PDUs connected to a network via the on-board network port. Dell UPS MUMC software can discover and monitor Dell PDUs connected to the network. The UPS and PDUs can then transmit SNMP data via Ethernet to the OpenManage™ Power Center, which aggregates and displays that information.
Dell’s power management software incorporates the traditional graceful server shutdown operations with enhanced support for large and distributed IT network infrastructures, as well as deeply integrated support for virtualized and private cloud systems.

Dell Multi-UPS Management Console (MUMC) software is designed to manage multiple UPS with attached server installations from a centralized client location. MUMC also directly manages virtualized systems, often without the need for an agent to be installed on the local hypervisor. This software can reduce the complexity and time required to manage system shutdown profiles and UPS settings across a network. Where virtualization is used, the MUMC can eliminate the need for command line programming and complex hypervisor integration with a simple and unique interaction with hypervisor management systems.

A complete set of capabilities is provided with MUMC. These include:
  • The ability to monitor and manage multiple power and environmental devices from any internet browser or vCenter dashboard
  • A user-definable tree structure enabling grouping, access and management of multiple devices across multiple locations
  • The option to view groups or similar devices and all alerts from a single interface
  • Auto discovery, providing fast installation by automatically detecting devices on the network
  • A power device asset management that tracks moves, additions and changes of equipment
  • Visible SNMP devices and individual web interfaces that are accessible for editing and configuration
  • Multiple password-protected access levels and support to provide secure communications
Dell UPS Local Node Manager (ULNM) software provides graceful, automatic shutdown of servers during prolonged power disruptions, helping to prevent data loss and save work in progress. For virtualized systems without a central hypervisor management interface such as VMware’s vCenter, the ULNM will also act as a shutdown agent for the individual hypervisors.

Dell ULNM:
  • Helps avoid data loss by automatically shutting down computers and virtual machines/servers powered by a Dell UPS during an extended power outage
  • Allows access through an easy-to-use interface from any PC with a web browser
  • Acquires UPS information through local or network communication and can be easily deployed on many computers
  • Can be remotely managed, configured and updated with the Dell Multi UPS Management software
  • Communicates with the protected device directly (by USB) or through the Network Management Card
The Dell UPS software supports virtualized server environments.
  • Integration with popular virtualization platforms from VMware®, Microsoft®, Citrix®, OpenSource and Red Hat® to manage power to a virtualized environment
  • Seamless integration with VMware® vCenter dashboard, support for remote shutdown of servers in clusters and the ability to shut down VMs in VMware® high-availability clusters
  • Ability to trigger vCenter vMotion™ and SCVMM Live Migration™ applications to transparently move virtual machines from a server affected by a power interruption to a nonaffected server on the network, helping to maintain data integrity with no downtime
  • XenCenter™ plugin
  • Support for Metered and Managed Dell PDUs
  • Support for multiple redundant UPS powering the same devices
  • Support for Dell unique metrics (peak headroom, peak consumption)
  • Support for Dell Environmental Monitoring Probe (EMP) to monitor temperature, humidity and the status of two dry contacts
  • Improved diagnostics and reporting tools
  • Improved translated documentation
close
 
 