What are the error messages for the Dell PowerEdge M1000e Enclosure?

Summary: Partial listing of M1000e chassis error messages, severity and potential causes.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms


When the PowerEdge M1000e blade enclosure that houses your blade servers encounters a problem, an error message will display on the LCD screen on the front of the chassis or the Chassis Management Controller (CMC) System Event Logs (SEL).

The following tables show possible error messages and their causes so that you can fix the error and clear the message.
The Events and Error Message Reference Guide for Dell EMC PowerEdge servers provides information about all the events and error messages generated by the system firmware and agents that monitor system components.

CMC Status Screen error messages

 

Severity

Error message

Cause

Critical

CMC <number> Battery: Battery sensor for CMC, failed was asserted

CMC CMOS battery is missing or has no voltage.

Critical

CMC <number> CPU Temp: Temperature sensor for CMC, failure event

CMC CPU temperature has exceeded the critical threshold.

Critical

CMC <number> Ambient Temp: Temperature sensor for CMC, failure event

CMC ambient temperature has exceeded the critical threshold.


          

Enclosure/Chassis Status Screen error messages

 

Severity

Error message

Cause

Critical

Chassis Fan <number> presence: Fan sensor for Chassis Fan, device removed was asserted

The removed fan is required for proper cooling of the enclosure/chassis.

Critical

Power Supply Redundancy: PS Redundancy sensor for Power Supply, redundancy lost was asserted

One or more power supply units (PSUs) has failed or been removed so the system is no longer redundant.

Critical

Power Supply Redundancy: PS Redundancy sensor for Power Supply, non-redundant: insufficient resources

One or more PSU has failed or been removed and the system lacks enough power to maintain normal operations. Servers could power down.

Critical

Control Panel Temp: Temperature sensor for Control Panel, failure event

The Chassis/Enclosure temperature exceeded the critical threshold.

Critical

CMC<number>Stand-alone: Micro Controller sensor for CMC, non-redundant was asserted

The CMC is no longer redundant. This message will only show if the standby CMC was removed or failed.

Critical

Chassis Eventlog CEL: Event Log sensor for Chassis Eventlog, all event logging disabled was asserted

The CMC cannot log events when the Event Log sensor is disabled. The Event Log is disabled when it becomes full. Clearing the log re-enables event logging.

Critical

Chassis Eventlog CEL: Event Log sensor for Chassis Eventlog, log full was asserted

The chassis device detects that only one entry can be added to the CEL before it is full.

Warning

Chassis Eventlog CEL: Event Log sensor for Chassis Eventlog, log almost full was asserted

The chassis event log is 75% full.

Warning

Power Supply Redundancy: PS Redundancy sensor for Power Supply, redundancy degraded was asserted

One or more PSU has failed or been removed and the system can no longer support full PSU redundancy.

 

Fan Status Screen error messages

 

Severity

Error message

Cause

Critical

Chassis Fan <number> Status: Fan sensor for Chassis Fan, failure event

The speed of the specified fan is not sufficient to provide enough cooling to the system.


 

IOM Status Screen error messages

 

Severity

Error message

Cause

Critical

I/O Module <number> Status: Module sensor for I/O Module, transition to critical from less severe was asserted

The I/O module has a fault. The same error can also happen if the I/O module is thermal-tripped.

Warning

I/O Module <number> Status: Module sensor for I/O Module, transition to non-critical from OK was asserted

The IO module has a fabric mismatch or a link tuning mismatch.

 

iKVM Status Screen error messages

 

Severity

Error message

Cause

Non-Recoverable

Local KVM Health: Module sensor for Local KVM, transition to non-recoverable was asserted

The Serial RIP or USB host chip has failed.

 

Critical

Local KVM Health: Module sensor for Local KVM, transition to critical from less severe was asserted

The USB host enumeration or OSCAR failure has failed.

Warning

Local KVM Health: Module sensor for Local KVM, transition to non-critical from OK was asserted

There has been a minor failure, such as corrupted firmware.

 

PSU Status Screen error messages

 

Severity

Message

Cause

Critical

Power Supply PSU <number>: Power Supply sensor for Power Supply, failure was asserted

The PSU has failed.

Critical

Power Supply PSU <number>: Power Supply sensor for Power Supply, input lost was asserted

The AC power cord has been unplugged or there has been a loss of AC power.

 

Server Status Screen error messages for M1000e Blade servers

 

Severity

Error message

Cause

Warning

System Board Ambient Temp: Temperature sensor for System Board, warning event

The server ambient temperature crossed a warning threshold.

Critical

 

System Board Ambient Temp: Temperature sensor for System Board, failure event

 

The server ambient temperature crossed a failing threshold.

Critical

System Board CMOS Battery: Battery sensor for System Board, failed was asserted

The CMOS battery is not present or has no voltage.

 

Warning

System Board Current Monitor: Current sensor for System Board, warning event

 

The current crossed a warning threshold.

Critical

System Board Current Monitor: Current sensor for System Board, failure event

The current has crossed a failing threshold.

Critical

<voltage sensor name>: Voltage sensor for System Board, state asserted was asserted

The voltage is out of range.

Critical

 

CPU<number> Status: Processor sensor for CPU<number, IERR was asserted

 

The CPU has failed.

Critical

CPU<number> Status: Processor sensor for CPU<number>, thermal tripped was asserted

The CPU has overheated.

Critical

CPU<number> Status: Processor sensor for CPU<number, configuration error was asserted

The processor is the incorrect type or in the wrong location.

Critical

CPU<number> Status: Processor sensor for CPU<number>, presence was deasserted

The required CPU is missing or not present.

Critical

System Board Video Riser: Module sensor for System Board, device removed was asserted

 

The required module was removed.

 

Critical

Mezz B Status: Add-in Card sensor for Mezz B, install error was asserted

 

The incorrect Mezzanine card is installed for I/O fabric.

Critical

Mezz C Status: Add-in Card sensor for Mezz C, install error was asserted

The incorrect Mezzanine card was installed for I/O fabric.

Critical


Backplane Drive <number>: Drive Slot sensor for Backplane, drive removed

The storage drive was removed.

Critical


Backplane Drive <number>: Drive Slot sensor for Backplane, drive fault was asserted

The storage drive failed.

Critical


System Board PFault Fail Safe: Voltage sensor for System Board, state asserted was asserted

This event is generated when the system board voltages are not at normal levels.

Critical


System Board OS Watchdog: Watchdog sensor for System Board, reboot was asserted

The iDRAC watchdog detected that the system has crashed (the timer expired because no response was received from host) and the action is set to reboot.

Critical


System Board OS Watchdog: Watchdog sensor for System Board, power off was asserted

The iDRAC watchdog detected that the system has crashed (the timer expired because no response was received from host) and the action is set to power off.

Critical


System Board OS Watchdog: Watchdog sensor for System Board, power cycle was asserted

The iDRAC watchdog detected that the system has crashed (the timer expired because no response was received from Host) and the action is set to power cycle.

Critical


System Board SEL: Event Log sensor for System Board, log full was asserted

The SEL device has detected that only one entry can be added to the SEL before it is full.

Warning


ECC Corr Err: Memory sensor, correctable ECC ( <DIMM Location> ) was asserted

Correctable ECC errors have reached a critical rate.

Critical


ECC Uncorr Err: Memory sensor, uncorrectable ECC ( <DIMM Location> ) was asserted

An uncorrectable ECC error was detected.

Critical

I/O Channel Chk: Critical Event sensor, I/O channel check NMI was asserted

A critical interrupt has been generated in the I/O Channel.

Critical

PCI Parity Err: Critical Event sensor, PCI PERR was asserted

A parity error was detected on the PCI bus.

Critical

PCI System Err: Critical Event sensor, PCI SERR ( <Slot number or PCI Device ID>) was asserted

The device detected a PCI error.

Critical

SBE Log Disabled: Event Log sensor, correctable memory error logging disabled was asserted

Single-bit error logging is disabled when too many SBEs are logged.

Critical

Logging Disabled: Event Log sensor, all event logging disabled was asserted

All error logging is disabled.

Non-Recoverable

CPU Protocol Err: Processor sensor, transition to non-recoverable was asserted

The processor protocol has entered a nonrecoverable state.

Non-Recoverable

CPU Bus PERR: Processor sensor, transition to non-recoverable was asserted

The processor bus PERR has entered a nonrecoverable state.

Non-Recoverable

CPU Init Err: Processor sensor, transition to non-recoverable was asserted

The processor initialization has entered a nonrecoverable state.

Non-Recoverable

CPU Machine Chk: Processor sensor, transition to non-recoverable was asserted

The processor machine check has entered a nonrecoverable state.

Critical


Memory Spared: Memory sensor, redundancy lost (<DIMM Location> ) was asserted

Memory spare is no longer redundant.

Critical


Memory Mirrored: Memory sensor, redundancy lost (<DIMM Location> ) was asserted

The mirrored memory is no longer redundant.

Critical

Memory RAID: Memory sensor, redundancy lost (<DIMM Location> ) was asserted

The RAID memory is no longer redundant.

Critical

Memory Cfg Err: Memory sensor, configuration error (<DIMM Location> ) was asserted

The memory configuration is incorrect for the system.

Warning


Mem Redun Gain: Memory sensor, redundancy degraded (<DIMM Location> ) was asserted

The memory redundancy is downgraded but not lost.

Critical

PCIE Fatal Err: Critical Event sensor, bus fatal error was asserted

A fatal error is detected on the PCI bus.

Critical

Chipset Err: Critical Event sensor, PCI PERR was asserted

A chip error is detected.

Warning

Mem ECC Warning: Memory sensor, transition to non-critical from OK (<DIMM Location> ) was asserted

Correctable ECC errors have surpassed a normal rate.

Critical

Mem ECC Warning: Memory sensor, transition to critical from less severe ( <DIMM Location> ) was asserted

Correctable ECC errors have reached a critical rate.

Critical

System Board POST Err: POST sensor for System Board, POST fatal error <additional error information> was asserted

See the Dell PowerEdge M1000e EnclosureOwner’s Manual for additional error information on BIOS POST errors.

Cause

Dell EMC

Resolution

Dell Technologies

Article Properties


Affected Product

PowerEdge M1000E

Last Published Date

06 Apr 2021

Version

4