Dell PERC 5/x Integrated Adapter Firmware Update

AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides the Dell PERC 5/i Integrated, 5/E Adapter Firmware Update and is supported on Enterprise Servers and Powervault models running the following Windows Operating System: NA.
To view all drivers for your PowerEdge 1950, go to Drivers and downloads.
Recommended
Loading the latest available version of the driver...

This is the latest Dell validated version of this driver

This is not the latest Dell validated version of this driver

SAS-RAID_Firmware_WJG5R_WN32_5.2.2-0072_A08.EXE | 6.24 MB
This is a large file. Depending on your connection speed, it may take some time to download.

File Format: Update Package for MS Windows 32-Bit
File Name: SAS-RAID_Firmware_WJG5R_WN32_5.2.2-0072_A08.EXE
File Size: 6.24 MB
Format Description
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
bc0ce36419f519a3dd449eecd894eb00
SHA1:
3fb9f3cc9f4a9d26cce213d99669138aec96d91c
SHA-256:
Not available

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

4.0 Fixes/Enhancements
======================

1. Fixed an issue where OS does not boot if 5.2.1-0066 firmware with some specific disk geometry (CHS) considerations (for example: 32sec/track).
2. Fixed an issue where user was not notified of a failed power supply unit in the MD1000 enclosure.
3. Addressed an issue where controller boot was failing when 50+ SATA drives are connected.
4. Added Notification of Cache State Changes when power is lost to external enclosures.
5. Added more diagnostic information on the IO Processor registers during failures - added testability feature.
Read More

Version

5.2.2-0072, A08

Release date

09 May 2012

Download Type

Firmware

Category

SAS RAID

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
View Important Information

File Format: One or more self extracting disk images inside of a self extracting zip
File Name: BR189340.exe
File Size: 1.54 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
bcba0a2a4d6f7848f6af385fe103ebf8
SHA1:
Not available
SHA-256:
Not available

File Format: A GnuPG file which contains a cryptographic signature
File Name: SAS-RAID_Firmware_WJG5R_LN32_5.2.2-0072_A08.BIN.sign
File Size: 194 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
ad90ff13e1e51f3db60b49ca0853b72f
SHA1:
03b826c9fb29be57672841a3f11a7957b02c4651
SHA-256:
Not available

File Format: ZipPack External
File Name: DELL_PERC-5-E-ADAPTER_A08_R189340.exe
File Size: 1.33 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
3e0223a29585dc109088c4caff3be9bc
SHA1:
83ce8909736b1f0982600bbabf9b1c6c02946c34
SHA-256:
Not available

File Format: External release notes
File Name: R189340.txt
File Size: 14.64 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file format contains plain text which can be viewed with a standard text editor.
To ensure the integrity of your download, please verify the checksum value.
MD5:
4d80a85373be734e4ebb6c6f598dd898
SHA1:
Not available
SHA-256:
Not available

File Format: Update Package for Red Hat Linux
File Name: SAS-RAID_Firmware_WJG5R_LN32_5.2.2-0072_A08.BIN
File Size: 4.31 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
945e6726ed7c0e5890d33a8298e565e7
SHA1:
d7c325cd50166bb84fd2d4beca5614c7c6c6952f
SHA-256:
Not available

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
DO NOT USE THIS FIRMWARE PACKAGE IF CONNECTING THER PERC 5/E CONTROLLER TO AN MD1000 ENCLOSURE IN SPLIT MODE (maintain PERC 5.2.1-0066). There is a known limitation to this FW package when connecting to enclosures in split mode.

1. When viewing SATA physical disk properties from Ctrl-R or other management applications, the Vendor Identification will be translated as "ATA".

2. If all physical disks making up a virtual disk are removed from the system or enclosure, the RAID controller will delete the virtual disk. If the disks are later re-inserted, they will be marked foreign and can be imported using a management application.

3. If the cable connecting a PERC 5/E to an enclosure is removed, the RAID controller will immediately delete all virtual disks on that enclosure. To recover, power down the server and ensure all cables in the configuration are securely connected. When the server is powered on, the RAID controller will detect the disks as foreign and the configuration can be imported with a management application.

4. Physical disks determined to contain a foreign configuration are not available for configuration as a new dedicated or global hotspare, or as a member of a new virtual disk. The foreign configuration must be imported or cleared from the physical disk before it may be used as a hotspare or member of a virtual disk. Physical disks with a foreign configuration will not appear on the Create New VD screen in Ctrl-R.

5. Prior to performing a virtual disk migration, the source system must be powered off before removal of the physical disks to preserve the correct virtual disk state. This is not required for the target system and the physical disks may be inserted while the system is powered on or off.

6. This version of firmware will not ensure complete compatibility with an older version of the management application, OpenManage 5.0 or 5.1. OpenManage 5.2 or greater is recommended.

7. It is recommended that the customer upgrade the management application and device driver to the latest version available from Dell at the time of installation of this firmware.

8. The firmware restricts the importing of virtual disks that are undergoing RAID level migration or Capacity Expansion. Do not interrupt virtual disks that are performing either of these operations because it will disable the ability to import the virtual disk and the data will be unavailable. Dell recommends that the user perform a data backup before starting these operations.

9. Foreign dedicated hot spares are now imported as global hot spares.

10. Default Physical disk cache settings for hard drives are ON for SATA drives and OFF for SAS drives.

11. A EMM change or a drive migration is not a supported action during a Capacity Expansion or Raid Level Migration. This may cause the VDs to go offline.
Dell recommends the user to take a data backup before starting these operations.

12. A Rebuild operation cannot be stopped/interrupted from the Ctrl+R configuration utility but can be done from the Dell Open Manage Storage Management Software.
PERC 5/E Adapter
PERC 5/i Integrated
2.0 Performing the Firmware Upgrade
===================================

Web pack:
---------

Download
1. Click Download Now, to download the file.
2. When the File Download window appears, click Save
this program to disk and click OK. The Save In: window appears.
3. From the "Save As" field, click the down arrow then click to
select Desktop and click Save. The file will download to your desktop.
4. If the Download Complete window appears, click Close. The file
icon appears on your desktop.

Hard Drive Floppy Disk Creation
1. Get 2 blank, formatted floppy disks.
2. Double-click the new icon (it looks like a floppy diskette) on
the desktop. The Self-Extractor window appears.
3. Click the 'Continue' button on the self-extractor window after inserting
one of the formatted floppies.
4. The utility prompts the user to insert the second floppy diskette after
it completes writing on the first floppy.
5. Remove the first floppy and insert the second floppy diskette.
6. Press 'Continue' button.
7. After all the files have been copied to the last floppy disk, press the 'Finish'
button to close the Self-Extracter window

Install
1. Insert the first (or the only) disk of the set into the Floppy
drive.
2. Click Start, click Shutdown, click Restart, and then click OK.
3. Follow the on-screen instructions.

Zip pack:
---------

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click on the OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
4. After flash is complete, remove bootable media.
5. Reboot system for changes to take effect.

Windows Update Package:
-----------------------

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click
the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the "Install" button.
5. Follow the remaining prompts to perform the update.

Linux Update Package:
---------------------

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to
your hard drive.

Installation
1. Read over the release information presented by executing the
"./FRMW_LX_RXXXXXX.BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing "./FRMW_LX_RXXXXXX.BIN" from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:
----------------------------------------------------------------------------

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to
your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file,
FRMW_LX_RXXXXXX.BIN.

Drivers help and tutorials