  • Issue 1: iDRAC might not send an event when your system reboots.

    Description: Sometimes, the iDRAC might not send an event when your system reboots. In this case, OMIVV sends latest health update notification by polling mechanism and you receive the latest health update within an hour.

    Version affected: 4.0 and later

  • Issue 2: iDRAC license type and description are displayed incorrectly for non-compliant vSphere hosts.

    Description: If a host is noncomplaint when CSIOR is disabled or has not been run, the iDRAC license information is displayed incorrectly although valid iDRAC license is available. Hence, you can view the host in vSphere hosts list, but when you click the host for details, the information in iDRAC License Type is displayed as empty and iDRAC License Description is displayed as "Your license needs to be upgraded."

    Version affected: 4.0 and later

    Resolution/Workaround: Perform any one of the following:
    1. Fix CSIOR compliance and run the inventory.
    2. Log in to iDRAC to get the license information.
  • Issue 3: Although deployment job fails due to inaccessible file share, the status is displayed as “Cancel.”

    Description: When you create an ISO profile with invalid credentials such as, invalid credentials for CIFS share, and select the same ISO profile for deployment, the deployment task fails. However, the status displayed in the Jobs page as Cancel instead of Failed.

    Version affected: 3.0 and later

    Resolution/Workaround: None

  • Issue 4: Dell EMC icon is not displayed after unregistering vCenter from an earlier OMIVV version and then registering same vCenter with a later OMIVV version.

    Description: If you unregister an earlier OMIVV version with vCenter server, and then register a later OMIVV version with the same vCenter server, there is an entry in the vSphere-client-serenity folder, which is old data from the earlier OMIVV version. Hence, the Dell EMC icon is not displayed after registering the later OMIVV version as old data specific to the earlier OMIVV version exists in the vSphere-client-serenity folder of the vCenter appliance.

    Version affected: All

    Resolution/Workaround: Perform the following steps:
    1. Restart vSphere Client on the vCenter server.
    2. If the issue persists:
      • For VMware vCenter, go to /etc/vmware/vsphere-client/vc-packages/vsphere-client-serenity and for Windows vCenter, go to C:\ProgramData\VMware\vCenterServer\cfg\vsphere-client\vc-packages\vsphere-client-serenity folder in the vCenter appliance and see if the old data exists, such as: com.dell.plugin.OpenManage_Integration_for_VMware_vCenter_WebClient-X.0.0.xxx.
      • Manually deleted the folder corresponding to the earlier OMIVV version
      • Restart vSphere Client services for vSphere Client (HTML-5).
  • Issue 5: The OpenManage Integration icon is not displayed after backup and restore from an earlier OMIVV version to a later OMIVV version.

    Description: The OpenManage Integration icon is not displayed after restoring an earlier OMIVV version appliance database to a later OMIVV version appliance.

    Version affected: 3.0 and later

    Resolution/Workaround: The IP address of the later OMIVV version appliance must be the same as the earlier OMIVV version appliance for the plug-in to work correctly after restore.

  • Issue 6: Storage overview returning incorrect number of hard drives for inventory

    Description: Systems with software RAID show incorrect number of hard drives on the storage overview page.

    Version affected: All

    Resolution/Workaround: None. The ESXi does not support software RAID. If the system has software RAID, it shows incorrect disks.

  • Issue 7: System Event Logs are not showing in OpenManage Integration for VMware vCenter when power supply redundancy is lost.

    Description: When the power redundancy is lost on the PowerEdge modular servers, the system logs get cleared.

    Version affected: 3.0 and later

    Resolution/Workaround: None

  • Issue 8: Chassis and server health is displayed as warning on the Chassis Summary page when server becomes critical.

    Description: When a critical entry is made to SEL logs, the health of the server (modular) changes to critical. This is correctly reflected on the Host Summary page. However, this is not reflected on the Chassis Summary page. The server health is displayed as warning. If the chassis was normal earlier, the health of the chassis also changes to warning.

    Version affected: 3.0 and later

    Resolution/Workaround: None. This is a known defect in the RACADM. The defect will be fixed in the next release of RACADM for chassis.

  • Issue 9: The hard drive name is not displayed at data center and cluster level inventory in some situations.

    Description: Although the hard drive name is displayed when you view the inventory at the host level, the hard drive name is displayed empty when you view the inventory of the host at the data center and cluster level.

    Version affected: 3.0 and later

    Resolution/Workaround: This issue does not affect the functionality of the features, and you can view the inventory at the host level to see the hard drive name.

  • Issue 10: Hard disk option is not disabled in the Deployment wizard for all the servers that do not contain hard disk drives.

    Description: While navigating through the Deployment wizard, if the bare-metal servers do not have any hard disk drive, and then the hard disk option should be disabled on the Select Deployment Options page. However, the option is available for selection.

    Version affected: 2.0 and later

    Resolution/Workaround: None

  • Issue 11: Using OpenManage Integration to update an Intel Network card with the firmware version of 13.5.2 is not supported.

    Description: There is a known issue with Dell EMC PowerEdge 12th generation servers and some Intel network cards with the firmware version of 13.5.2. Updating some models of the Intel network cards at this version of firmware fails when the firmware update is applied using the iDRAC with Lifecycle Controller.

    Version affected: All

    Resolution/Workaround: Update the network driver software using an operating system. If the Intel network card has a version of firmware other than 13.5.2, you can update using OpenManage Integration.

    NOTE: :

    When using the one-to-many firmware update, avoid selecting Intel network adapters that are at version 13.5.2, as this fails and stops the update task from updating remaining servers.

  • Issue 12: Firmware upgrade or downgrade of Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) from firmware version of 6.2.x or earlier is not supported.

    Description: Using the OpenManage Integration to upgrade a Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) from firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or earlier is not supported.

    Version affected: All

    Resolution/Workaround: There is a known issue with the Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) where updating the adapter from firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or earlier fails when the update is applied using the iDRAC with Lifecycle Controller.

    When attempting to perform this update using the OpenManage Integration, the update may incorrectly show that it completed successfully. However, the firmware update has failed and remains at the previous level. One way to successfully update the adapter software for the Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) is to update the adapter firmware from an operating system.

  • Issue 13: Associated host credential profile is not displayed on the management compliance page when inventory is not able to get iDRAC IP for the host.

    Description: If the iDRAC IP is not retrieved because of non-responsive iDRAC, the inventory fails and host to be associated with the host credential profile is not displayed on the management compliance page.

    Version affected: 1.6 and later

    Resolution/Workaround: Reset the iDRAC to fix the issue of iDRAC not being responsive, and then rerun the inventory. If the inventory can get the iDRAC IP, then the host is associated with the correct host credential profile.

  • Issue 14: Unable to boot to service partition while deploying OS ISO.

    Description: OS deployment is failing on 12th generation PowerEdge servers with the following error on the screen during POST: "Warning: Unable to boot to Service Partition." There is a BIOS issue to identify the network ISO when there is a local USB CD-ROM installed on the system and that USB CD- ROM is the only USB mass storage device plugged into the system.

    Version affected: 1.5.1 and later

    Resolution/Workaround: Remove the local USB CD-ROM (not all local CD-ROM would expose this issue), or plug in extra USB floppy or USB drive on the system, or attach the virtual media (virtual floppy and virtual CD) from the iDRAC.

  • Issue 15: A firmware update fails with an error message saying that USC is in use and it must be retried after 30 seconds.

    Description: During a firmware update, the update fails with the error message: If USC is in use, wait until USC has exited and retry the action. Otherwise retry after 30 seconds to check if network connectivity caused this error.

    Version affected:1.5.1 and later

    Resolution/Workaround: To fix this issue, reset iDRAC and wait until iDRAC boots properly and try the firmware update again.

  • Issue 16: Events from different vCenter are posted to another vCenter from a shared OpenManage Integration appliance.

    Description: This situation can occur when a bare-metal server that was deployed in one vCenter is rediscovered again as bare-metal server but then selected for an OS deployed in another vCenter. This situation occurs if the host that was already on one of the registered vCenter was added to another registered vCenter. In this case, the host on first vCenter opens as disconnected.

    Version affected: All

    Resolution/Workaround: Remove the host from the first vCenter where it is now showing as disconnected.

  • Issue 17: OS installation fails.

    Description: OS installation fails with the error message: Mount network share failed – incorrect IP address or share name.

    Version affected: 1.5 and later

    Resolution/Workaround: Restart the appliance.

  • Issue 18: Health Status is showing Warning for chassis when one or more power supplies is critical.

    Description: The overall health information is displayed warning on summary page for VRTX chassis that has power supply in critical state.

    Version affected: All

    Resolution/Workaround: Each power supply status is shown correctly as critical.

  • Issue 19: Health Status is showing as Healthy for chassis while Storage status is Warning.

    Description: The overall health information is displayed Healthy on summary page for VRTX chassis that has a storage component as Warning.

    Version affected: VRTX firmware version 2.0

    Resolution/Workaround: Each power supply unit health status correctly shown as critical at OMIVV.

  • Issue 20: Blower information is showing as N/A for a chassis when a Blower is removed.

    Description: Blower inventory information is displayed as N/A on the Hardware page for VRTX chassis when a Blower is removed from a slot.

    Version affected: 2.0 and later

    Resolution/Workaround: You can see the correct status in the CMC console.

  • Issue 21: I see a web communication error in the vSphere Client after changing the DNS settings in OpenManage Integration for VMware vCenter.

    Description: If you see any kind of web communication error in the vSphere Client while doing any OMIVV-related tasks after changing the DNS settings, clear the browser cache or log out and log in from the vSphere Client.

    Version affected: 2.x and later

    Resolution/Workaround: Clear the browser cache or log out and log in from the vSphere Client.

  • Issue 22: OMIVV RPM Upgrade fails when Proxy is configured with Domain user authentication.

    Description: If OMIVV appliance is configured with proxy to reach the Internet and proxy is authenticated using NTLM authentication, then the RPM update fails due to the issues in the underlying yum tool.

    Version Affected: OMIVV 4.0 and later

    Resolution/Workaround: Do back up and restore to update the OMIVV appliance.

  • Issue 23: Unable to apply system profile that has PCIe card in the FX chassis.

    Description: The OS deployment fails on a target server if the source server has PCIe card information when using an FX chassis. The System profiles on the source server have different fc.chassislot ID than the one on the target server. OMIVV tries to deploy the same fc.chassislot ID on the target server but fails. The System profiles searches for exact instance( FQDD) while applying the profile, which works successfully on rack servers (identical), but may have few restrictions in modular servers. For example, in FC640, the System profiles that are created from one modular server cannot be applied on other modular servers in the same FX chassis because of NIC level restrictions.

    Version Affected: OMIVV 4.1 and later

    Resolution/Workaround: System profile that is taken from an FC640 server in slot 1 of a FX2s chassis can only be applied on another FC640 server residing in the slot 1 of another FX2s chassis.

  • Issue 24: The first inventory (immediately after creating a host credential profile) may fail in ESXi 6.5 and later version where the WBEM enablement is necessary.

    Resolution: Trigger the inventory again from Jobs.

  • Issue 25: After backup and restore from an earlier OMIVV version to a later OMIVV version, the following issues may be observed:
    • The Dell EMC logo is not displayed at vCenter.
    • The 2000000 error
    • The 3001 error

      Resolution:

      • Restart vSphere Web Client on the vCenter server.
      • If the issue persists:
        • For VMware vCenter, go to /etc/vmware/vsphere-client/vc-packages/vsphere-client-serenity and for Windows vCenter, go to C:\ProgramData\VMware\vCenterServer\cfg\vsphere-client\vc-packages\vsphere-client-serenity folder in the vCenter appliance and see if the old data exists, such as: com.dell.plugin.OpenManage_Integration_for_VMware_vCenter_WebClient-X.0.0.xxx.
        • Manually deleted the folder corresponding to the earlier OMIVV version
  • Issue 26: Proactive HA-related features are not functioning as expected after modifying the vCenter credentials.

    Description: If the vCenter credentials are modified by using the OMIVV portal after registering the OMIVV to a vCenter, the Proactive HA-related features will not function as expected.

    Resolution: If you are using the Proactive HA feature along with OMIVV, do not modify the registered user credentials. If the credentials require modification, unregister and register OMIVV appliance to vCenter with new username.

    Version Affected: 4.3 and later

  • Issue 27: When upgrading or downgrading some iDRAC firmware versions using OMIVV, even when the firmware update is successful, OMIVV may indicate that the job is failed.

    Description: During firmware update, when you downgrade or upgrade the iDRAC versions such as 3.20.20.20, 3.21.21.21, and 3.21.21.22, the job status is indicated as failed even when the job was successfully run.

    Resolution: Refresh the inventory after the job failure and rerun the job for other components.

    Version Affected: 4.3 and later

  • Issue 28: Configuring the System Lockdown mode at a cluster level sometimes displays a message "No hosts under the cluster has successful inventory."

    Description: Configuring the System Lockdown mode at a cluster level sometimes displays a message "No hosts under the cluster has successful inventory." This message is displayed even when the cluster has successfully inventoried the 14G hosts that are managed by OMIVV.

    Resolution: Reboot the vCenter.

    To reboot the vCenter, do the following:
    1. Log in to the vSphere Client with a vCenter Single Sign-on Administrator account.
    2. Go to Administration > Deployment > Deployment > System Configuration.
    3. Click Nodes, select the vCenter Server Appliance node, and click the Related Objects tab.
    4. Reboot the vCenter node.

    Version Affected: 4.3 and later

  • Issue 29: Sometimes post RPM upgrade of OMIVV appliance, multiple entries in the logs are seen in vCenter Recent Tasks.

    Description: Sometimes, after RPM upgrade, multiple entries are displayed in logs when viewed on vCenter Recent Tasks.

    Resolution: Restart the vCenter services.

    Version Affected: 4.3 and later

  • Issue 30: Sometimes, the storage inventory data is not displayed for the host managed using chassis credential profile and present in member chassis.

    Description: The storage data may not be displayed for an MX host managed using the chassis credential profile and for a host present in the member chassis. Though the inventory data of other components is displayed, only the storage-related data is not displayed

    Resolution: Do one of the following:
    1. Update the MX7000 chassis firmware version to 1.00.10.
    2. Manage the host using iDRAC.
    3. Reinstall the host in another slot of the same MX7000 chassis and retry the operation.

    Version Affected: 4.3 and later.

  • Issue 31–146440: Chassis firmware update fails on small deployment mode.

    Resolution: Chassis firmware update is supported only on medium, large, and extra large mode.

    Version Affected: 5.0

  • Issue 32–147664: Guest OS details of OMIVV appliance are incorrectly displayed in ESXi.

    Resolution: This is a known issue with open-vm-tools 10.2.5 which is bundled with CentOS 7.6. OMIVV 5.0 appliance runs on CentOS 7.6.1810 (64-bit).

  • Issue 33–147679: Inventory or warranty job fails to trigger after backup and restore.

    Description: Before taking the backup from 4.x, if you clear the inventory or warranty schedule days, and disable the inventory or warranty schedule, and then restore this backup to 5.x, inventory or warranty job fails to trigger.

    Resolution: Contact Dell EMC technical support for further assistance.

    Version Affected: 5.0

  • Issue 34–148132: For a non-administrator user, inventory fails indicating that the enabling WBEM service is failed on host.

    Resolution: For more information about the required privilege for non-administrator user, see the OMIVV 5.0 User's Guide. Assign the required privilege to user and run the inventory again.

    Version Affected: 5.0

  • Issue 35–144171:Chassis inventory fails in OMIVV after promoting backup lead as a lead.

    When the lead chassis of the MCM group is powered off or not functional, the backup lead gets promoted as the lead chassis. In this case, inventory of the lead and member chassis fails in OMIVV.

    Resolution: Perform the following:
    1. Make the previous lead chassis active and run the inventory from OMIVV.
    2. Delete the chassis credential profile and all the chassis present in the group from OMIVV.
    3. Add the new lead chassis to rediscover the group.

    Version Affected: 5.0

  • Issue 36–147023: Host firmware update fails, if a canceled firmware update job of related chassis is present.

    If you cancel the firmware update job of a PowerEdge MX chassis, subsequent host firmware update job for hosts present in the same chassis is blocked.

    Resolution: Purge the canceled chassis firmware update job to release the lock on the related hosts.

    Version Affected: 5.0

  • Issue 37–143173: OMIVV page displays invalid session, or time out exception, or two million errors in Firefox browser.

    If the OMIVV page is idle for some time (5–10 minutes), the invalid session, or time out exception, or two million errors is displayed.

    Resolution: Refresh the browser. If the issue persists, log out and log in from vCenter.

    To see the correct data in OMIVV, ensure that you complete the task listed in resolution.

    Version Affected: 5.0

  • Issue 38–135743: Time shown for Power Monitoring inventory of the hosts is incorrect when viewed from datacenter and cluster level.

    Resolution: See the host level inventory for correct details.

    Version Affected: 5.0


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\