The SYSCFG utility failure messages provide error codes to help diagnose why some commands do not succeed. The following table lists SYSCFG error codes and messages.

Table 1. SYSCFG Error Codes and Messages
Error Code Message
0 Success
1 Attempt to read write-only parameter.
2 Password cannot exceed 16 characters.
3 A BMC was either not detected or is not supported.
4 This username is already in use. Enter a unique username.
5 Access mode not supported.
6 Cannot return number of requested data bytes.
7 User ID 1 cannot be assigned a username.
8 Cannot execute duplicated request.
9 There was an error clearing the SEL.
10 Clear SEL cannot be accompanied with any other option.
11 racreset cannot be accompanied with any other option.
12 Cannot execute command. Command, or request parameter(s), not supported in present state.
13 Command not supported on given channel.
14 The community string may only contain printable ASCII characters.
15 Destination unavailable. Cannot deliver request to selected destination.
16 Cannot execute command. Insufficient privilege level.
17 Command illegal for specified sensor or record type.
18 Invalid commstring value.
19 Hardware subsystem error. Invalid data field in Request.
20 Invalid destination IP address.
21 The GUID is invalid.
22 Invalid gateway.
23 Invalid hostname.
24 Invalid IP address.
25 Invalid DNS IP address.
26 Invalid sub net mask.
27 Invalid value for PEF. PEF value should be between 1 and 16.
28 Reservation Canceled or Invalid Reservation ID.
29 Invalid Time to live value.
30 Invalid VLANID value.
31 Invalid Command. Used to indicate an unrecognized or unsupported command.
32 Command invalid for given LUN.
33 Load defaults cannot be accompanied with any other option.
34 There was an error loading the defaults.
35 Node Busy. Command could not be processed because command processing resources are temporarily unavailable.
36 Out of space. Command could not be completed because of a lack of storage space required to execute the given command operation.
37 This parameter is not supported.
38 Parameter out of range. One or more parameters in the data field of the Request are out of range.
39 The password may only contain printable ASCII characters.
40 Password test failed.
41 Requested data length invalid.
42 Requested data field length limit exceeded.
43 Requested Sensor, data, or record not present.
44 Request data truncated.
45 Command response could not be provided.
46 Command response could not be provided. BMC initialization or initialization agent in progress.
47 Command response could not be provided. Device in firmware update mode.
48 Command response could not be provided. SDR Repository in update mode.
49 Cannot execute command, SEL erase in progress.
50 Attempt to set the 'set in progress' value when not in the 'set in complete' state.
51 The SOL character ’accumulate interval’ is invalid.
52 The SOL character ’send threshold’ is invalid.
53 The SOL ’retry interval’ is invalid.
54 Command completed successfully.
55 Time-out while processing command. Response unavailable.
56 Unspecified error.
57 The password may only contain printable ASCII characters.
58 Username cannot exceed 16 characters.
59 Invalid VLANID value. Enter in ’dddd’ format.
60 Attempt to write read-only parameter.
61 BMC is busy.
62 Response data did not return successfully.
63 BMC time out error.
64 Option requires an argument.
65 The asset tag for this system is not available.
66 The asset tag cannot be more than 10 characters long.
67 The required BIOS interfaces cannot be found on this system.
68 The BIOS version information is not available.
69 There is not enough free system memory to complete the BIOS update.
70 The BIOS update file version is a different version class (A00, X00) than the current system BIOS. Use the --force option to use this BIOS image.
71 The BIOS update file version is older than the current system bios. Use the --force option to use this BIOS image.
72 The BIOS update file version is identical to the current system bios. Use the --force option to use this BIOS image.
73 The sequence list must be a comma-separated numerical list of valid unique boot device numbers (ex: 2, 1, 3).
74 The sequence list must be a comma-separated list of valid unique device names (ex: nic.emb.1, hdd.emb.1) or a comma-separated numerical list of valid unique boot device numbers (ex: 2, 1, 3).
75 There was an error setting the sequence.
76 The list is not formatted correctly. See the help for more details.
77 The size of returned buffer is larger than the size of allocated buffer.
78 There was a problem getting the state byte.
79 The state byte is not available on this system.
80 There was a problem setting the state byte.
81 The state byte must be a value between 0 and 255 decimal.
82 The CPU information is not available.
83 The dependent option required for this subcommand is missing in the command line.
84 Duplicate sub command has been entered.
85 The script file does contain not a valid DTK environment script signature.
86 The format of the environment variable is incorrect.
87 The --envar option can only be used for a single option.
88 The --envar option can only be used for report operations.
89 The individual sub commands should be specified for the -s option.
90 Getting external serial connector settings failed.
91 Setting external serial connector settings failed.
92 There was an error opening the file.
93 File does not have write permission.
94 The file contains invalid options.
95 The replication information does not match for this system.
96 There can only be one section in the input file.
97 Bad ini file, the section cannot be found.
98 The format of the bios image file is incorrect.
99 Report operations and set operations must be separate.
100 Help is not available for the option.
101 The -x (--hex) option can only be used with -b or -r.
102 Input file not found.
103 Input file cannot be read.
104 Invalid argument for option.
105 Function table lookup error.
106 The machine ID was not found in the file.
107 The system memory information is not available.
108 Mode can only be used with the --pci option.
109 The device name or index must be present in the boot order.
110 The output file could not be opened. Please make sure the path exists and the media is not write protected.
111 Could not write to output file, disk may be full.
112 The current password must be supplied with a new password using --oldsyspwd.
113 The current password must be supplied with a new password using --oldsetuppwd.
114 The current password can only be supplied when setting a new password.
115 Actions are not allowed for this filter. Only alerts are allowed.
116 There was an error getting the option.
117 The option is not available or cannot be configured through software.
118 There was an error setting the option.
119 The -n (--namefile) option can only be used with - -pci.
120 The password may only contain alphanumeric characters.
121 The BIOS passwords have been disabled via jumper.
122 The password length must be between 1 and 32.
123 This password is locked and can only be unlocked by the admin user.
124 There was an error setting the password.
125 The LCD string length must be between 1 and %s.
126 The LCD string may only contain alphanumeric characters.
127 There was an error setting the LCD string.
128 The second channel can only be set if the RAID controller is set to RAID.
129 The set operation requires sub commands.
130 The service tag for this system is not available.
131 The system ID value is not available.
132 The system information string is not available.
133 A system error has occurred.
134 Usage error.
135 The uuid information is not present on this system
136 Version cannot be accompanied with any other option.
137 The self-identify blinker timer should be set to 0..255 second(s).
138 Encrypt key is too long.
139 Encrypt key is invalid, accepted characters are 0 to 9 or A to F.
140 Parameter has been temporarily disabled due to a dependency on other settings.
141 The old password supplied is incorrect. The new password will not be set. Please try again.
142 Cannot stat /etc/omreg.cfg file. Please ensure /etc/omreg.cfg file is present and is valid for your environment. You can copy this file from the DTK iso.
143 Getting nicselection settings failed.
144 HAPI Driver Load Error.
145 Filter action power reduction is only supported for the system power warn/fail filters.
146 TPM/TCM Clear settings requires setup password.
147 There is currently no TPM/TCM Clear request pending.
148 Password is not required for retrieving the ’%s’ options.
149 Setup password is required for setting the ’%s’ options.
150 Invalid Password override.
151 Invalid TPM/TCM set option.
152 There was an error setting the TPM/TCM option.
153 There is no setup password installed on this system.
154 The setup password supplied is incorrect. Please try again.
155 Profile should be custom for setting cpupowermode, memorypowermode and fanmode.
156 There was an error setting the Power Option.
157 The power cap value entered is out of range. Please try again.
158 The power cap value entered must be between 0 to 100 if unit is percent.
159 Invalid IPv6 address. The IPv6 address cannot be link-local or multicast.
160 Invalid IPv6 address. The IPv6 address specified has incorrect address format.
161 Invalid IPv6 address. The gateway address specified has incorrect address format.
162 Invalid IPv6 address. The Primary DNS server address specified has incorrect address format.
163 Invalid IPv6 address. The Secondary DNS server address specified has incorrect address format.
164 Invalid IPv6 address. The gateway address specified is invalid.
165 Invalid configuration. Attempting to apply IPv6 configuration on a non supported platform.
166 Invalid IPv6 configuration. Attempt to set DNS server address manually while DNS address source is set to auto.
167 Invalid IPv6 configuration. Attempt to set IPv6 address manually while IPv6 address source is set to auto.
168 Invalid IPv6 configuration. Attempting to apply IPv6 configuration without loading IPv6 stack.
169 Invalid IPv4 configuration. Attempting to apply IPv4 configuration with IPv4 disabled.
170 Invalid IPv6 configuration. Ipv6 address cannot be specified without specifying prefix-length.
171 Invalid IPv6 configuration. dnssrcv6 cannot be set to auto when ipsrcv6 is set to manual.
172 Error while executing IPMI Set command.
173 Error while executing IPMI Get command.
174 Error during Trap Alert.
175 Unspecified error.
176 Getting LCD settings failed.
177 Invalid configuration. Attempting to set cap when capenable is set to disable.
178 Invalid configuration. Attempting to set cap when hardware does not support setting.
179 Invalid Configuration Option.
180 Cannot execute command. Parameter is illegal because command sub-function has been disabled or is unavailable.
181 Failed to report the removable flash media redundancy status.
182 Failed to report the Internal SD Module status.
183 Error locating the Virtual Media Key on the Modular system.
184 Error in setting the redundancy option for the Internal SD Modules.
185 Error in retrieving the redundancy option for the Internal SD Modules.
186 Error in setting the redundancy option on Modular systems for the Internal SD Modules.
187 Error in retrieving the vFlash option.
188 Error in setting the vFlash option.
189 The set operation failed due to dependency.
190 The set operation failed because attribute is forced to a value.
191 Cannot disable this OrderedList’s entries.
192 The set operation failed because system is busy now . Try again later.
193 New value for the token not valid.
194 Token not found.
195 The set operation failed because System Services and/or CSIOR disabled.
196 The set operation failed due to pending System Password changes.
197 The set operation failed due to Password verification failure.
198 The set operation failed due to previously scheduled job.
199 The set operation failed because attribute is suppressed.
200 The set operation failed due to Generic failure.
201 XML path context creation failed.
202 Unable to parse XML.
203 Unable to connect data manager.
204 'root' privileges required to execute this application.
205 Invalid alert destination.
206 The set operation failed due to unspecified error.
207 Incorrect syntax for help. For more information about a particular command, use the option '-h or --help' followed by the command name. Example: %s -h --asset

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\