Dell OpenManage Server Administrator 版本 7.3 命令行界面指南

指定最小和最大警告阈值的值

如果您要指定风扇探测器警告阈值的值,则必须指定要配置的探测器的编号,最小和/或最大警告阈值。在以下示例中,要配置的探测器为探测器 0。第一个命令只设置最小阈值;第二个命令则可以设置最小和最大阈值:
omconfig chassis fans index=0 minwarnthresh=4580
omconfig mainsystem fans index=0 minwarnthresh=4580
omconfig chassis fans index=0 minwarnthresh=4580 maxwarnthresh=9160
omconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160
发出该命令后,系统将设置您指定的值,然后显示以下消息:
Fan probe warning threshold(s) set successfully.
  • 注: 您不能为 PowerEdge 9G 系统上的风扇探测器设置最小和最大警告阈值。