Dell OpenManage Server Administrator Version 7.3 Command Line Interface Guide

Omconfig Reset All Temperature Probe Thresholds

Table 1. oOmconfig Reset All Temperature Probe Thresholds

Description

Resets the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure.
  • NOTE: This command is not supported on SCSI RAID controllers.

Syntax

omconfig storage enclosure action=resetalltempprobes controller=id enclosure=< ENCLOSUREID> , where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Example to

Reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on controller 1.

Example for SAS controllers

omconfig storage enclosure action= resetalltempprobes controller=1 enclosure=2:3