Known Issues

  • Issue 1:

    Description

    XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in Network Device page and OS.

    Resolution

    Virtual reseat or Physical reseat of the server

    Versions/Systems Affected

    All CMC versions including CMC 3.00 for Dell PowerEdge VRTX and PowerEdge servers with iDRAC7 or earlier.

  • Issue 2:

    Description

    After Shared PERC8 controller update, RAID-related operations may take longer to report status.

    Resolution

    Wait for the operation status to report.

    Versions/Systems Affected

    CMC version 2.01 or later for Dell PowerEdge VRTX.

  • Issue 3:

    Description

    An error occurs while importing CMC configuration file using local racadm or remote racadm.

    Resolution

    This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using the command, “racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.

    Versions/Systems Affected

    CMC Version 2.0 or later for Dell PowerEdge VRTX

  • Issue 4:

    Description

    At times when foreign drives are inserted, the Chassis Overview Health tab does not display the alert, “Foreign Configuration was detected on Physical Disk”.

    Resolution

    None. The alert is not displayed only at times. But, the functionality for foreign configuration is not affected.

    Versions/Systems Affected

    All CMC versions including CMC 3.00 for Dell PowerEdge VRTX

  • Issue 5:

    Description

    When CMC firmware is downgraded to 1.36 from 2.00 or later while network share is configured, the Server Components Update page gets corrupted.

    Resolution

    Clear the network configuration before downgrading to 1.36

    Versions/Systems Affected

    CMC Version 1.36 or earlier for Dell PowerEdge VRTX

  • Issue 6:

    Description

    When pinned cache is present, the controller failover feature does not work.

    Resolution

    Address the pinned cache before controller failover is allowed.

    Versions/Systems Affected

    All CMC versions including CMC 3.00 for Dell PowerEdge VRTX.

  • Issue 7:

    Description

    While VD re-build operation is in progress, if SPERC controller fail-over is triggered, active alert for degraded VD is not displayed on the Chassis Overview page.

    Resolution

    None. An active alert along with the CMC Log is generated for degraded VD (VDR8) before the SPERC controller fail-over is triggered. After the SPERC controller fail-over occurs, the Active Alert message for degraded VD on the chassis overview page is cleared, but SPERC functionality is not impacted.

    Versions/Systems Affected

    All CMC versions including CMC 3.00 for Dell PowerEdge VRTX.

  • Issue 8:

    Description

    MCM Inventory report has limited RAID and NIC details. There is a difference in the RAID and NIC inventory details on the Server Component Update page and the MCM inventory report.

    Resolution

    In the CMC GUI, refer to the Server Overview > Update > Server Component Update page, it is accurate and current.

    Versions/Systems Affected

    All CMC versions including CMC 3.00 for Dell EMC PowerEdge VRTX.