This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section. The trap variables are sent in the order in which they are listed.
  • NOTE: The PowerEdge M1000e CMC, PowerEdge VRTX CMC and PowerEdge FX2 CMC do not generate the traps in this section. They generate the traps documented in the CMC Traps.
Table 1. RAC Traps
TrapID Name Description Severity Category Cause Supported by RAC Platform
0 CodeStart SNMP agent is initializing itself Information Status RAC power on or reset. All
1 Authentication Failure Request received with an invalid community name Critical Error SNMP request with an invalid community name. All
1001 alertDrscTest TrapEvent The RAC generated a test trap event in response to a user request Information Status A test SNMP trap generated by a RAC. All
1002 alertDrscAuth Error RAC Authentication failures during a time period have exceeded a threshold Minor Error RAC login failure caused by authentication failure, number of concurrent logins exceed limit, or permission denied. All
1015 alertDrscSEL Warning The RAC has detected a new event in the System Event Log with Severity: Warning Major Error RAC detected a new system event log with warning severity (detailed log info is in drsAlert Message varbind). All
1016 alertDrscSEL Critical The RAC has detected a new event in the System Event Log with Severity: Critical Critical Error RAC detected a new system event log with critical severity (detailed log info is in drsAlert Message varbind). All
1017 alertDrscSEL 80 percentFull The RAC system event log is 80% full Major Status RAC detected system event log is 80% full. All
1018 alertDrscSEL 90 percentFull The RAC system event log is 90% full Major Status RAC detected system event log is 90% full. All
1018 alertDrscSEL 90 percentFull The RAC system event log is 90% full Major Status RAC detected system event log is 90% full. All
1020 alertDrscSEL Normal The RAC has detected a new event in the System Event Log with Severity: Normal Information Error RAC detected a new system event log with normal severity (detailed log info is in drsAlert Message varbind). All