Error code
|
Message information
|
ASR0000
|
Message
|
The watchdog timer expired. |
Details
|
The operating system or an application failed to
communicate within the time-out period.
|
Action
|
Check the operating system, application, hardware,
and system event log for exception events.
|
|
ASR0001
|
Message
|
The watchdog timer reset the system. |
Details
|
The operating system or an application failed to
communicate within the time-out period. The system was reset.
|
Action
|
Check the operating system, application, hardware,
and system event log for exception events.
|
|
ASR0002
|
Message
|
The watchdog timer powered off the system. |
Details
|
The operating system or an application failed to
communicate within the time-out period. The system was shut down.
|
Action
|
Check the operating system, application, hardware,
and system event log for exception events.
|
|
ASR0003
|
Message
|
The watchdog timer power cycled the system. |
Details
|
The operating system or an application failed to communicate
within the time-out period. The system was power-cycled.
|
Action
|
Check the operating system, application, hardware,
and system event log for exception events.
|
|
BAT0002
|
Message
|
The system board battery has failed. |
Details
|
The system board battery is either missing or bad. |
Action
|
See
Getting help.
|
|
BAT0017
|
Message
|
The <
name> battery has failed.
|
Details
|
The <
name> battery is either missing, bad,
or unable to charge due to thermal issues.
|
Action
|
Check system fans. If the problem persists, see
Getting
help
.
|
|
CPU0000
|
Message
|
CPU <
number> has an internal error (IERR).
|
Details
|
System Event Log and Operating System Logs may indicate
that the exception is external to the processor.
|
Action
|
Review System Event Log and Operating System Logs.
If the issue persists, see
Getting help.
|
|
CPU0001
|
Message
|
CPU <
number> has a thermal trip (over-temperature)
event.
|
Details
|
The processor temperature increased beyond the operational
range.
|
Action
|
Review the logs for fan failures. If no fan failures
are detected, check inlet temperature (if available) and reinstall
processor heat sink. If the problem persists, see
Getting help.
|
|
CPU0005
|
Message
|
CPU <
number> configuration is unsupported.
|
Details
|
System is unable to boot or may run in a degraded
state.
|
Action
|
Review the technical specifications for supported
processor types.
|
|
CPU0010
|
Message
|
CPU <
number> is throttled.
|
Details
|
The CPU is throttled due to thermal or power conditions. |
Action
|
Review system logs for power or thermal exceptions. |
|
CPU0023
|
Message
|
CPU <
number> is absent.
|
Action
|
Verify processor installation. If present, re-seat
the processor.
|
|
CPU0204
|
Message
|
CPU <
number> <
name> voltage is
outside of range.
|
Details
|
Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
|
Action
|
- Turn off the system and remove input power for one
minute.
- Ensure the processor is seated correctly.
- Reapply input power and turn on the system.
- If the issue persists, see
Getting help.
|
|
CPU0700
|
Message
|
CPU <
number> initialization error detected.
|
Details
|
System BIOS was unable to initialize the processor. |
Action
|
- Turn off the system and remove input power for one
minute.
- Ensure the processor is seated correctly.
- Reapply input power and turn on the system.
- If the issue persists, see
Getting help.
|
|
CPU0701
|
Message
|
CPU <
number> protocol error detected.
|
Details
|
System event log and operating system logs may indicate
that the exception is external to the processor.
|
Action
|
- Check system and operating system logs for exceptions.
If no exceptions are found, continue.
- Turn off the system and remove input power for one
minute.
- Ensure the processor is seated correctly.
- Reapply input power and turn on the system.
- If the issue persists, see
Getting help.
|
|
CPU0702
|
Message
|
CPU bus parity error detected. |
Details
|
System event log and operating system logs may indicate
that the exception is external to the processor.
|
Action
|
- Check system and operating system logs for exceptions.
If no exceptions are found, continue.
- Turn off the system and remove input power for one
minute.
- Ensure the processor is seated correctly.
- Reapply input power and turn on the system.
- If the issue persists, see
Getting help.
|
|
CPU0703
|
Message
|
CPU bus initialization error detected. |
Details
|
System event log and operating system logs may indicate
that the exception is external to the processor.
|
Action
|
- Check system and operating system logs for exceptions.
If no exceptions are found, continue.
- Turn off the system and remove input power for one
minute.
- Ensure the processor is seated correctly.
- Reapply input power and turn on the system.
- If the issue persists, see
Getting help.
|
|
CPU0704
|
Message
|
CPU <
number> machine check error detected.
|
Details
|
System event log and operating system logs may indicate
that the exception is external to the processor.
|
Action
|
- Check system and operating system logs for exceptions.
If no exceptions are found, continue.
- Turn off the system and remove input power for one
minute.
- Ensure the processor is seated correctly.
- Reapply input power and turn on the system.
- If the issue persists, see
Getting help.
|
|
FAN0000
|
Message
|
Fan <
number> RPM is less than the lower
warning threshold.
|
Details
|
Fan operating speed is out of range. |
Action
|
Remove and reinstall the fan. If the issue persists,
see
Getting help.
|
|
FAN0001
|
Message
|
Fan <
number> RPM is less than the lower
critical threshold.
|
Details
|
Fan operating speed is out of range. |
Action
|
Remove and reinstall the fan. If the issue persists,
see
Getting help.
|
|
HWC1001
|
Message
|
The <
name> is absent.
|
Details
|
The absent device may be necessary for proper operation.
System functionality may be degraded.
|
Action
|
Reinstall or reconnect the hardware. |
|
HWC2003
|
Message
|
The storage <
name> cable is not connected,
or is improperly connected.
|
Details
|
The cable may be necessary for proper operation.
System functionality may be degraded.
|
Action
|
Check if the cable is present, then reinstall or
reconnect.
|
|
HWC2005
|
Message
|
The system board <
name> cable is not connected,
or is improperly connected.
|
Details
|
The cable may be necessary for proper operation.
System functionality may be degraded.
|
Action
|
Check if the cable is present, then reinstall or reconnect. |
|
MEM0000
|
Message
|
Persistent correctable memory errors detected on
a memory device at location(s) <
location>.
|
Details
|
This is an early indicator of a possible future uncorrectable
error.
|
Action
|
Re-seat the memory modules. If the issue persists,
see
Getting help .
|
|
MEM0001
|
Message
|
Multi-bit memory errors detected on a memory device
at location(s) <
location>.
|
Details
|
The memory module has encountered an uncorrectable
error. System performance may be degraded. The operating system and/or
applications may fail as a result.
|
Action
|
Re-seat the memory modules. If the issue persists,
see
Getting help.
|
|
MEM0007
|
Message
|
Unsupported memory configuration; check memory device
at location <
location>.
|
Details
|
The memory may not be seated correctly, misconfigured,
or has failed. Memory size is reduced.
|
Action
|
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Getting help.
|
|
MEM0701
|
Message
|
Correctable memory error rate exceeded for <
location>.
|
Details
|
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
|
Action
|
Re-seat the memory modules. If the issue persists,
see
Getting help.
|
|
MEM0702
|
Message
|
Correctable memory error rate exceeded for <
location>.
|
Details
|
The memory may not be operational. This an early
indicator of a possible future uncorrectable error.
|
Action
|
Re-seat the memory modules. If the issue persists,
see
Getting help.
|
|
MEM1205
|
Message
|
Memory mirror redundancy is lost. Check memory device
at location(s) <
location>.
|
Details
|
The memory may not be seated correctly, misconfigured,
or has failed.
|
Action
|
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Getting help.
|
|
MEM1208
|
Message
|
Memory spare redundancy is lost. Check memory device
at location <
location>.
|
Details
|
Memory sparing is no longer available. |
Action
|
Re-seat the memory modules. If the issue persists,
see
Getting help.
|
|
MEM8000
|
Message
|
Correctable memory error logging disabled for a memory
device at location <
location>.
|
Details
|
Errors are being corrected but no longer logged. |
Action
|
Review system logs for memory exceptions. Reinstall
memory at location <
location>.
|
|
PCI1302
|
Message
|
A bus time-out was detected on a component at bus
<
bus> device<
device> function <
func>.
|
Details
|
System performance may be degraded. The device has
failed to respond to a transaction.
|
Action
|
Cycle input power, update component drivers, if device
is removable, reinstall the device.
|
|
PCI1304
|
Message
|
An I/O channel check error was detected. |
Action
|
Cycle input power, update component drivers, if device
is removable, reinstall the device.
|
|
PCI1308
|
Message
|
A PCI parity error was detected on a component at
bus <
bus>device<
device>function <
func>.
|
Details
|
System performance may be degraded, PCI device may
fail to operate, or system may fail to operate.
|
Action
|
Cycle input power, update component drivers, if device
is removable, reinstall the device.
|
|
PCI1320
|
Message
|
A bus fatal error was detected on a component at bus
<
bus>device<
device>function <
func>.
|
Details
|
System performance may be degraded, or system may
fail to operate.
|
Action
|
Cycle input power, update component drivers, if device
is removable, reinstall the device.
|
|
PCI1342
|
Message
|
A bus time-out was detected on a component at slot
<
number>.
|
Details
|
System performance may be degraded, or system may
fail to operate.
|
Action
|
Cycle input power, update component drivers, if device
is removable, reinstall the device.
|
|
PCI1348
|
Message
|
A PCI parity error was detected on a component at
slot <
number>.
|
Details
|
System performance may be degraded, or system may
fail to operate.
|
Action
|
Cycle input power, update component drivers, if device
is removable, reinstall the device.
|
|
PCI1360
|
Message
|
A bus fatal error was detected on a component at slot
<
number>.
|
Details
|
System performance may be degraded, or system may
fail to operate.
|
Action
|
Cycle input power, update component drivers, if device
is removable, reinstall the device.
|
|
PST0128
|
Message
|
No memory is detected. |
Details
|
System BIOS was unable to detect memory in the system. |
Action
|
Re-seat the memory modules. If the issue persists,
see
Getting help.
|
|
PST0129
|
Message
|
Memory is detected, but is not configurable. |
Details
|
System BIOS detected memory, but was unable to configure
the memory for system operation.
|
Action
|
Compare system memory installation to supported system
memory configurations.
|
|
RFM1008
|
Message
|
Failure detected on Removable Flash Media <
name>.
|
Details
|
An error was reported during a SD card read or write. |
Action
|
Reseat the flash media. If the problem persists,
see
Getting help.
|
|
RFM1014
|
Message
|
Removable Flash Media <
name> is write protected.
|
Details
|
The card is write-protected by the physical latch
on the SD card. A write-protected card cannot be used.
|
Action
|
If unintended, remove the media and disable write
protection.
|
|
SEC0031
|
Message
|
The chassis is open while the power is on. |
Details
|
The chassis is open. System performance may be degraded,
and security may be compromised.
|
Action
|
Close the chassis. Check system logs. |
|
SEC0033
|
Message
|
The chassis is open while the power is off. |
Details
|
The chassis was opened while the power was off. System
security may have been compromised.
|
Action
|
Close the chassis and verify hardware inventory. Check
system logs.
|
|
SEL0006
|
Message
|
All event logging is disabled. |
Details
|
This message is displayed when all event logging
has been disabled by the user.
|
Action
|
If unintended, re-enable logging. |
|
SEL0008
|
Message
|
Log is full. |
Details
|
When the event log is full, additional events are
not written to the log. Older events may be overwritten and lost.
This message may also appear if the user disabled event logging.
|
Action
|
Backup and clear log. |
|
SEL0012
|
Message
|
Could not create or initialize the system event log. |
Details
|
If the system event log fails to initialize, platform
status and failure events are not captured. Some management software
do not report platform exceptions.
|
Action
|
Reboot the management controller or iDRAC. Cycle
system input power. If problem persists call support.
|
|
SEL1204
|
Message
|
An unknown system hardware failure detected. |
Details
|
If the system event log failed to initialize, platform
status and failure events are not captured. Some management software
do not report platform exceptions.
|
Action
|
Re-configure system to the minimum supported configuration.
If issues persists, contact support.
|
|
TMP0118
|
Message
|
The system inlet temperature is less than the lower
warning threshold.
|
Details
|
Ambient air temperature is too cool. |
Action
|
Check the system operating environment. |
|
TMP0119
|
Message
|
The system inlet temperature is less than the lower
critical threshold.
|
Details
|
Ambient air temperature is too cool. |
Action
|
Check the system operating environment. |
|
TMP0120
|
Message
|
The system inlet temperature is greater than the
upper warning threshold.
|
Details
|
Ambient air temperature is too warm or one or more
fans may have failed.
|
Action
|
Check the system operating environment and review
event log for fan failures.
|
|
TMP0121
|
Message
|
The system inlet temperature is greater than the
upper critical threshold.
|
Details
|
Ambient air temperature is too warm or one or more
fans may have failed.
|
Action
|
Check the system operating environment and review
event log for fan failures.
|
|