Dell PowerEdge Express Flash NVMe PCIe SSD Adapter User’s Guide

Software RAID array created by using PCIe SSDs is not detected after SLES 11 is rebooted

Cause
The boot.md service is not started during RAID creation. The boot.md service must be enabled for the init process to start the MD-RAID device.
Solution
Run the command # chkconfig boot.md to verify if the boot.md service is on or off. This command should start the boot.md service. If it does not, run the command # chkconfig boot.md on to enable it.