Table 1. oOmconfig Reset All Temperature Probe Thresholds

Description

Resets the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure.
  • NOTE: This command is not supported on SCSI RAID controllers.

Syntax

omconfig storage enclosure action=resetalltempprobes controller=id enclosure=< ENCLOSUREID> , where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Example to

Reset the thresholds for all temperature probes in enclosure 3 attached to connector 2 on controller 1.

Example for SAS controllers

omconfig storage enclosure action= resetalltempprobes controller=1 enclosure=2:3