Failure Messages

The RAIDCFG utility failure messages provide error codes to help diagnose why some commands do not succeed. See table below for a list of the error codes and the associated messages.

Table 1. RAIDCFG Error Codes and Messages
Error Code Message
0 RAIDCFG Command successful!
1 Error! Incorrect Syntax.
2 Failure!
3 Illegal operation
4 Unsupported operation
5 Device not found.
6 Format boot drive illegal
7 Buffer too small.
8 Virtual Disk contains boot partition. Use force option to delete.
9 Init boot drive failed.
10 Format boot drive failed.
11 Cannot write boot drive.
12 Unsupported RAID value.
13 Invalid RAID configuration.
14 Span depth not in range.
15 RAID 1 failed.
16 Exactly 2 array disks are required to create a RAID 1 virtual disk.
17 Unsupported stripe size value.
18 RAID 5 only.
19 RAID 5 error.
20 A minimum of 3 array disks are required to create a RAID 5 virtual disk.
21 RAID 0 failed.
22 RAID 10 failed.
23 RAID 50 failed.
24 RAID 5 not supported.
25 RAID 50 not supported.
26 Size too small for given RAID type.
27 Wrong number of disks for RAID 1- concatenated.
28 Insufficient space to mirror disks.
29 Create Mirror not supported.
30 Disk in use.
31 Disk Lock operation failed.
32 Disk locked.
33 Disk Unlock operation failed.
34 Disk Unlocked.
35 Disk failed on rebuild.
36 Hot Spare not free.
37 Disk Diagnostic failed.
38 Disk Rebuild failed.
39 Disk Format failed.
40 Cancel of Disk Diagnostic failed.
41 Cancel of Disk Rebuild failed.
42 Cancel of Disk Format failed
43 Assign Hot Spare failed
44 Disk too Small for Hot Spare.
45 Unassign Hot Spare failed.
46 Prepare Disk for Removal failed.
47 Disk Online failed.
48 Disk Offline failed.
49 UnMount Operation failed.
50 Mount Operation failed.
51 Cannot Format Array Disk.
52 Bad chunk size.
53 Invalid disk.
54 Virtual disk not found.
55 Virtual disk locked.
56 Drive in use.
57 Reached maximum physical size.
58 Reached maximum count of virtual disks.
59 There is not enough free space on the array disk(s) to allow the operation to complete; the size of the virtual disk is too large; or communication to the array disk(s) has been lost.
60 Limit your array disk selection to those disks already included in another single virtual disk or to those array disks that are not used at all by another virtual disk.
61 Invalid Parameter
62 Failed drive cannot be added.
63 The controller cannot support the number of array disks that you have selected. Choose a smaller number.
64 Delete virtual disk failed. Controller busy.
65 Delete virtual disk failed.
66 Create virtual disk failed.
67 Create virtual disk failed. Controller busy.
68 Create virtual disk failed. Failed to map virtual disk to operating system disk.
69 Create virtual disk failed. Failed to map virtual disk to operating system disk.
70 Virtual disk initialization failed.
71 Virtual disk initialization failed. Controller busy.
72 Virtual disk reconstruction failed. Controller busy.
73 Virtual disk resynching failed. Controller busy.
74 Flush Virtual disk's cache failed on controller.
75 Virtual disk partition specified not found.
76 Unsupported cache policy value.
77 Unsupported write policy value.
78 Unsupported read policy value.
79 Cancel initialization on virtual disk failed.
80 Cancel reconstruction on virtual disk failed.
81 Cancel resynchronization on virtual disk failed.
82 The maximum number of virtual disks that can be created has been reached.
83 The new virtual disk must use only the remaining free space on the array disks used in the last virtual disk you created. Select all array disks that are used in the last virtual disk you created.
84 You have selected an array disk that is in a degraded or failed state. Choose another array disk.
85 Delete the last created virtual disk first.
86 Virtual disk initialized for use and no override requested.
87 Virtual disk type requested is invalid for the attempted operation.
88 Virtual disk Move operation failed. Cannot rename, virtual disk is already in use.
89 Failover invalid.
90 Virtual disk resynching.
91 Virtual disk resynch failed.
92 Virtual disk reconstruct failed.
93 Cannot format a virtual disk that contains a boot or system partition.
94 Cannot initialize a virtual disk that contains a boot or system partition.
95 Virtual disk Copy failed.
96 Virtual disk mirror set required.
97 Virtual disk Create - Read-only failed.
98 Virtual disk Create - Read-write failed.
99 Virtual disk - Clear-to-zero failed.
100 Virtual Disk Requires Non Multilevel.
101 Virtual Disk Promote Operation failed.
102 Specified virtual disk has no drive letter assigned to it.
103 Cannot expose virtual disk.
104 Cannot reconfigure virtual disk.
105 Cannot stop the reconfiguration of the virtual disk.
106 SMART report count not supported.
107 Operations on hidden virtual disks are not allowed.
108 Virtual disk is in use.
109 The virtual disk is in use. It cannot be reconfigured at this time.
110 Virtual disk operation is temporarily unavailable. Initialization in progress.
111 Virtual disk operation is temporarily unavailable. Reconstruction in progress.
112 Virtual disk operation is temporarily unavailable. Rebuild in progress.
113 Virtual disk operation is temporarily unavailable. Check consistency in progress.
114 Specified virtual disk too small.
115 Virtual disk operation not supported. Size too small.
116 Operation is temporarily unavailable. Space in use.
117 Cannot reconfigure to the given RAID level.
118 Cannot reconfigure from current RAID level to the given RAID level.
119 One of the array disks selected for the virtual disk is already in use.
120 Virtual disk operation not supported. Cannot use non-RAID disk.
121 Controller Read Configuration failed.
122 Controller Write Configuration failed.
123 Controller cache flush failed.
124 Enable alarm on controller failed.
125 Disable alarm on controller failed.
126 Quiet alarm on controller failed.
127 Controller failed to perform the task.
128 Specified bus not found for controller.
129 Call to set cache mode on the controller failed.
130 Unexpected controller error.
131 Controller out of memory.
132 Invalid controller state.
133 Controller failed.
134 Controller busy.
135 Controller does not exist.
136 Controller name is invalid.
137 Controller is iterated.
138 Rename of virtual disk was not successful.
139 The controller was not able to erase the file system from the specified virtual disk.
140 The controller was not able to add space to the specified concatenation set.
141 The controller was not able to get the status of the specified mirror set.
142 The controller was not able to set the requested failover space.
143 The controller cannot get the failover space information.
144 Controller cannot unmirror the specified virtual disk.
145 The controller could not split the specified virtual disk.
146 The controller could not lock the specified virtual disk.
147 Controller IO paused.
148 No controller parameter support.
149 Controller does not recognize parameter symbol.
150 Controller Battery Recondition failed.
151 Controller Get disk signature failed.
152 Controller Read Flags failed.
153 Controller Set Flags failed.
154 Controller Remove Snap Shot failed.
155 Controller not supported.
156 Controller device initialization failure.
157 Partner controller already opened readwrite.
158 No partner controller found.
159 The virtual disk is not valid for requested operation.
160 Cannot communicate with controller.
161 Set operation failed.
162 Operation to update error count of SMART device has failed.
163 Operation to clear error count of SMART device has failed.
164 Driver could not execute.
165 Cannot delete virtual disk.
166 Cannot set temperature probe. Invalid value entered.
167 Cannot set enclosure tag. Invalid value entered.
168 Cannot set enclosure alarm.
169 Temperature probe value out of range.
170 Cannot set cache mode.
172 Data will be lost on the secondary disk and a reboot will be forced.
173 Cluster Services (MSCS) is running. Deleting a virtual disk that contains a cluster resource can result in unpredictable errors or system hangs (quorum disk). You should shut down cluster services before deleting cluster resources. Are you sure you want to proceed?
174 Cannot perform Create Virtual Disk or Delete Virtual Disk while the other server in a cluster is online. Please shut one of the servers down and retry the operation.
176 Invalid array disks or failover drives selected for reconfigure/create operation. Please make sure that all array disks and failover drives associated with the virtual disk are selected.
177 The maximum number of partitions have already been created on one of the selected array disk(s). Each array disk can hold portions (partitions) of up to 10 virtual disks. This virtual disk cannot be created because one or more array disk(s) have reached the partition limit.
178 The virtual disk is in use. Please close any applications that use the virtual disk and unmount any file systems that reside on the virtual disk.
179 The firmware version is not supported. Please update the firmware from http://support.dell.com.
180 The specified device does not have enough free space to be used as failover space for the specified virtual disk.
181 The operation failed. Please rescan the controller and retry the operation.
182 The operation cannot be performed while a task is running on the specified virtual disk.
183 The specified virtual disk has no dead disk segments.
184 The operation cannot be performed at this time. The firmware can recondition a battery that has a Degraded or Power Low state. The firmware will not recondition a battery that is functioning normally or that has a Ready, Failed or Missing state.
185 The version of the controller firmware installed on your system does not support this operation.
186 There are no disks of the correct type available to be assigned as a hot spare.
187 There are no disks of sufficient size available to be assigned as a hot spare.
188 There are no disks of the correct type and sufficient size available to be assigned as a hot spare.
189 The Create Virtual Disk task was successful but the operating system may not be aware of the new virtual disk.
191 The import of foreign configurations is complete. Some configurations could not be imported.
192 Enable alarm command failed. The enclosure processor is busy or a firmware download is in progress.
193 Disable alarm command failed. The enclosure processor is busy or a firmware download is in progress.
194 Quiet alarm command failed. The enclosure processor is busy or a firmware download is in progress.
195 An error occurred while resetting a temperature probe.
200 No array disks found!
201 Invalid Virtual Disk ID!
202 RAID Type & Size are required to create a virtual disk. Ensure that the RAID type and the size are correct.
203 Invalid Environment command!
204 File is not writable!
205 Setting Environment Variable Command failed!
206 Filename is not provided!
207 Invalid Strict option! Please provide a valid number between 1 and 100.
208 Span depth is not needed for this RAID type.
209 Array disk(s) cannot be part of virtual disk(s) and also be hotspares.
210 Cannot have silent and logfile switch with the same command.
211 Invalid array disk(s)!
212 Invalid failover disk(s)!
213 Creation of a virtual disk on this RAID controller requires the use of the entire disk space of the array disks. The size or - sz parameter is not needed.
214 Invalid size given! size=max or -sz=max is not supported for this RAID controller.
215 The value given for envname or -envn is null or too long.
216 Invalid virtual disk size!
217 The strict option provided failed! Virtual disk is not created.
218 Unable to determine optimum size for Virtual disk. Ensure that the array disks are of the same protocol (i.e. SAS, SATA, SCSI). If there is a mismatch of the array disks then the RAIDCFG will not be able to determine the optimum size. In addition, also ensure that there is drive size available for the specified virtual disk.
219 One or more array disks selected to create virtual disk or hotspare doesn't have enough disk space. Please make sure that all the array disks and failover drives selected have enough free space.
220 The number of array disks provided is incorrect for the requested RAID Type! RAID 1 requires exactly 2 array disks, RAID 5 requires at least 3 array disks, RAID 10 requires at least 4 array disks and RAID 50 requires at least 6 array disks.
221 No free array disks found!
222 No global failover disks found!
223 One or more array disks selected for the virtual disk has foreign configuration.
224 Error in opening the file.
225 SAS 5/IR, SAS 6/IR, H200 and SW RAID requires atleast two physical disks to create RAID 0 or RAID 1.
226 No Foreign configuration present in the controller.
227 The virtual disk cannot be created on the physical disks you selected. Possible reasons include:unsupported mix of SAS and SATA protocol type disks, unsupported mix of SSD and HDD media disks.
228 Unsupported array disks selected for VD creation.
229 Setting stripe size is not supported in this controller.
230 Invalid VirtualDisk(VD) name specified. VD name can have alphanumeric characters [A-Z,a-z,0-9,_,-] only. Also, VD name size must be less than or equal to 15 characters
231 Error occurred while setting virtual disk as boot disk.
232 Error occurred while setting name for virtual disk.
233 Couldn't get boot virtual disk.
234 PCIe Link Speed could not be set for the RAID controller. Please check if the controller has the capability to set/change its PCIe link speed.
235 PCIe Link Speed can be set to either 2 or 3 i.e. PCIe Generation 2.0 or 3.0.
236 PCIe Link Speed could not be retrieved for this RAID controller.Please check if the controller has the PCIe link speed capability.
237 Please reset the controller before doing any further operation.

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"