Dell Lifecycle Controller Remote Services v2.30.30.30 Quick Start Guide

Exceptions while importing server profile

On certain Dell devices, successful application of a server configuration profile requires two imports. The first import of the profile enables hidden devices that are then configured with a second import.

Two imports are required while performing following actions:
  • Enabling RAID mode on storage controllers — PERC S110 and PERC S130 require two imports – one to set the embedded SATA controller to RAID mode and the second to configure the RAID controller for operations such as creating a virtual disk.

    Example:

    If the EmbSata BIOS attribute on the import system is not set to RAIDMode, then the first import must contain the following:
    <Component FQDD="BIOS.Setup.1-1">
                                              	<Attribute Name="EmbSata">RaidMode</Attribute>
                                              </Component>
                                           
    The second server import is to apply the configuration on the PERC controller:
    <Component FQDD="RAID.Embedded.1-1">
                                              	<Attribute Name="RAIDresetConfig">False</Attribute>
                                              	<Attribute Name="RAIDforeignConfig">Ignore</Attribute>
                                              <Component FQDD="Disk.Virtual.262145:RAID.Embedded.1-1">
                                              <Attribute Name="RAIDaction">Create</Attribute>
                                              <Attribute Name="Name">Virtual Disk 1</Attribute>
                                              <Attribute Name="Size">0</Attribute>
                                              <Attribute Name="StripeSize">128</Attribute>
                                              <Attribute Name="SpanDepth">1</Attribute>
                                              <Attribute Name="SpanLength">2</Attribute>
                                              <Attribute Name="RAIDTypes">RAID 0</Attribute>
                                              <Attribute Name="IncludedPhysicalDiskID">Disk.Direct.0-0:RAID.Embedded.1-1</Attribute>
                                              <Attribute Name="IncludedPhysicalDiskID">Disk.Direct.1-1:RAID.Embedded.1-1</Attribute>
                                              </Component>
                                              <Component FQDD="Disk.Direct.0-0:RAID.Embedded.1-1">
                                              	<Attribute Name="RAIDPDState">Ready</Attribute>
                                              </Component>
                                              <Component FQDD="Disk.Direct.1-1:RAID.Embedded.1-1">
                                              <Component FQDD="Disk.Direct.1-1:RAID.Embedded.1-1">
                                              	<Attribute Name="RAIDPDState">Ready</Attribute>
                                              </Component>
                                              </Component>
                                           
  • Enabling PCI slots — PCI slots in the system that are disabled in the BIOS require two imports – one to enable the slot and another to configure the card in the slot.

    Example

    If the Slot1 BIOS attribute on the import system is disabled, the first import must contain the following:
    <Component FQDD="BIOS.Setup.1-1">
                                              <Attribute Name="Slot1>Enabled</Attribute>
                                              </Component>
                                           

    A second import is required to configure the device in slot 1.