Перейти к основному содержимому
  • Простое и быстрое размещение заказов
  • Просмотр заказов и отслеживание состояния доставки
  • Создание списка продуктов и доступ к нему
  • Управление узлами, продуктами и контактами уровня продуктов Dell EMC с помощью Company Administration.

Dell PowerEdge R320 Getting Started Guide

PDF

Technical Specification

NOTE: The following specifications are only those required by law to ship with your system. For a complete and current listing of the specifications for your system, go to Dell.com/support.
Power
AC Power Supply (per power supply)
Wattage 350 W and 550 W
Heat dissipation
NOTE: Heat dissipation is calculated using the power supply wattage rating.

1356 BTU/hr maximum (redundant, 350 W power supply)

1531 BTU/hr maximum (non-redundant, 350 W power supply)

2132 BTU/hr maximum (redundant, 550 W power supply)

Voltage
NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.
100–240 V AC, autoranging, 50/60 Hz
Battery
Coin-cell battery 3 V CR2032 Lithium coin cell
Physical
Height 42.8 mm (1.68 inch)
Width
With rack latches 482.4 mm (18.99 inch)
Without rack latches 434.0 mm (17.08 inch)
Depth (excludes bezel) 607.0 mm (23.9 inch)
Weight (maximum) 19.3 kg (42.55 lb)
Weight (empty) 16.33 kg (36 lb)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Temperature
Operating Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH), with 26 °C max dew point. De-rate maximum allowable dry bulb temperature at 1 °C/300 m above 900 m (1°F per 550 ft).
NOTE: For information on supported expanded operating temperature range and configurations, see support.dell.com/manuals.
Storage –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour
Relative humidity
Operating 20% to 80% (noncondensing) at a maximum wet bulb temperature of 29 °C (84.2 °F)
Storage 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F)
Maximum vibration
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested)
Maximum shock
Operating One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms

Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 32 G faired square wave pulse with velocity change at 270 inches/second (685 centimeters/second)

Altitude
Operating –15.2 m to 3048 m (–50 to 10,000 ft)
NOTE: In compliance with the requirements of the official Chinese standards, the operating altitude for systems shipping in China is in the range of –15.2 m to 2000 m (–50 ft to 6560 ft).
NOTE: For altitudes above 2950 ft, the maximum operating temperature is derated 1 ºF/550 ft.
Storage –15.2 m to 10,668 m (–50 ft to 35,000 ft)
Airborne Contaminant Level
Class G1 as defined by ISA-S71.04-1985