--acpower

Option
--acpower
Valid Arguments on, off, last
Description Sets the behavior for the system after AC power is lost. This option specifies how the system responds to the restoration of AC power and is particularly useful in systems that are turned off using a power strip. When set to on, the system turns on after AC is restored. When set to off, the system does not turn on after AC is restored. When set to last, the system turns on if the system was on when AC power was lost; if the system was off when AC power was lost, the system remains off when power is restored. This option can be replicated.

Example:

A:>syscfg --acpower=on 
                                             acpower=on
                                          
Applicable Systems All Dell PowerEdge systems prior to PowerEdge 12G systems.