Preskočiť na hlavný obsah
  • Zadávajte objednávky rýchlo a jednoducho
  • Pozrite si svoje objednávky a sledujte priebeh doručenia
  • Vytvorte si zoznam svojich produktov a majte ho vždy poruke
  • Spravujte svoje lokality Dell EMC, produkty a kontaktné informácie na úrovni produktov pomocou Správy informácií o spoločnosti.

Dell OpenManage Server Administrator Version 7.4 User's Guide

BMC/iDRAC Platform Events Filter Alert Messages

The following table lists all possible Platform Event Filter (PEF) messages along with a description of each event.
Table 1. PEF Alert Events
Event Description
Fan Probe Failure The fan is running too slow or not at all.
Voltage Probe Failure The voltage is too low for proper operation.
Battery Probe Warning The battery is operating below the recommended charge level.
Battery Probe Failure The battery has failed.
Discrete Voltage Probe Failure The voltage is too low for proper operation.
Temperature Probe Warning The temperature is approaching excessively high or low limits.
Temperature Probe Failure The temperature is either too high or too low for proper operation.
Chassis Intrusion Detected The system chassis has been opened.
Redundancy (PS or Fan) Degraded Redundancy for the fans and/or power supplies has been reduced.
Redundancy (PS or Fan) Lost No redundancy remains for the system's fans and/or power supplies.
Processor Warning A processor is running at less than peak performance or speed.
Processor Failure A processor has failed.
Processor Absent A processor has been removed.
PS/VRM/D2D Warning The power supply, voltage regulator module, or DC to DC converter is pending a failure condition.
PS/VRM/D2D Failure The power supply, voltage regulator module, or DC to DC converter has failed.
Hardware log is full or emptied Either an empty or a full hardware log requires administrator attention.
Automatic System Recovery The system is hung or is not responding and is taking an action configured by Automatic System Recovery.
System Power Probe Warning The power consumption is approaching the failure threshold.
System Power Probe Failure The power consumption has crossed the highest acceptable limit and has resulted in a failure.
Removable Flash Media Absent The removable flash media is removed.
Removable Flash Media Failure The removable flash media is pending a failure condition.
Removable Flash Media Warning The removable flash media pending a failure condition.
Internal Dual SD Module Card Critical The internal dual SD module card has failed.
Internal Dual SD Module Card Warning The internal dual SD module card is pending a failure condition.
Internal Dual SD Module Card Redundancy Lost The internal dual SD module card has no redundancy.
Internal Dual SD Module Card Absent The internal dual SD module card is removed.

Ohodnotiť tento obsah

Presné
Užitočné
Jednoducho pochopiteľné
Bol pre vás tento článok užitočný?
0/3000 characters
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, hodnotenie (1 až 5 hviezdičiek).
  Vyberte, prosím, či vám článok pomohol alebo nie.
  Poznámky nemôžu obsahovať nasledujúce špeciálne znaky: <>()\