CMC Event Messages

CMC001

Message
The operation is successfully completed.
Detailed Description
The operation is successfully completed.
Recommended Response Action
No response action is required.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

CMC002

Message
Unable to complete the operation because of an unknown issue.
Detailed Description
The operation cannot be successfully completed because of an unknown issue.
Recommended Response Action
Do one of the following: 1) Retry the operation. 2) Reset CMC and retry the operation.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

CMC003

Message
Unable to complete the operation because the parameter arg1 is missing.
Arguments
arg1 = parameter name
Detailed Description
The operation cannot be completed because the parameter identified in the message is missing.
Recommended Response Action
Enter the missing parameter and retry the operation. For information about the parameters, see the CMC Profile document available on the support site.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

CMC004

Message
Unable to complete the operation because the parameter arg1 is invalid.
Arguments
arg1 = parameter name
Detailed Description
The operation cannot be completed because the parameter identified in the message is invalid.
Recommended Response Action
Enter a valid parameter and retry the operation. For information about valid parameters, see the CMC Profile document available on the support site.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

CMC005

Message
Unable to complete the operation because of a mismatch between AttributeName and AttributeValue count.
Detailed Description
The operation cannot be completed because of a mismatch between AttributeName and AttributeValue count.
Recommended Response Action
Enter a valid AttributeName and AttributeValue count, and then retry the operation.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

CMC401

Message
Changing the Reserved QuickDeploy IP Addresses setting to arg1 may create an issue in the future if higher density server nodes are inserted in to the Chassis (for example, quarter-height servers). Press OK to continue.
Arguments
arg1 = number of IP address
Detailed Description
Changing the Reserved QuickDeploy IP Addresses setting to <number of IP address> may create an issue in the future if higher density server nodes are inserted in to the Chassis (for example, quarter-height servers).
Recommended Response Action
Select a higher number to accomodate future higher density server node additions, otherwise no response action is required.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

CMC8501

Message
Chassis Group Leader has synchronized this members configuration.
Detailed Description
Multi Chassis Management feature on CMC allows for pushing the lead chassis configuration data to its members. This message appears in the members log when the configuration data is successfully synchronized with the Chassis group leaders configuration data.
Recommended Response Action
No response action required.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8502

Message
Unable to access the IPv6 information of the server.
Detailed Description
CMC is unable to access the specified servers IPv6 information. Unable to display the specified servers Launch iDRAC link on the CMC Web interface.
Recommended Response Action
Enable IPv6 for the specified server using the CMC command line or CMC Web GUI interface, so that the link to launch iDRAC is displayed on the CMC Web interface. For the command line options or navigation for Web interface, see the Troubleshooting section in the CMC Users Guide.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8503

Message
Unable to access the IPv4 information of the server.
Detailed Description
CMC is unable to access the IPv4 information for the specified server. Unable to display the specified servers Launch iDRAC link on the CMC Web interface.
Recommended Response Action
Enable IPv4 on the specified slots iDRAC via the CMC command line or Web GUI interface, for the iDRACs launch point to show up on the CMC web GUI. For the command line options or navigation for Web interface, see the Troubleshooting section in the CMC Users Guide.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8504

Message
Unable to access server: arg1 , because the NIC is disabled on the identified server.
Arguments
arg1 = slot number
Detailed Description
The NIC is disabled on the server identified in the message, and the CMC is unable to display the link to launch the iDRAC web interface.
Recommended Response Action
Enable the NIC on the server identified in the message using the CMC command line or CMC Web interface, so that the link to launch iDRAC is displayed on the CMC Web interface. To enable the NIC for DHCP using RACADM, enter "racadm setniccfg -m server-<slot number> -d" where <slot number> is the server identified in the message. To enable the NIC using the Web interface, click Server Overview > select the identified server, go to Setup > select the Enable LAN check box.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8505

Message
Unable to access server: arg1 because both IPv4 and IPv6 are disabled. NIC Enabled = arg2 .
Arguments
arg1 = slot number, arg2 = state
Detailed Description
IPv4 and IPv6 are disabled on the specified server and the CMC is unable to display the link to launch iDRAC web interface.
Recommended Response Action
Enable IPv4 or IPv6 for the specified server using the CMC command line or CMC Web GUI interface, so that the link to launch iDRAC is displayed on the CMC Web interface. To enable the NIC for DHCP using RACADM, enter "racadm setniccfg -m server-<slot number> -d" where <slot number> is the server identified in the message. To enable the NIC using the Web interface, click Server Overview > select the identified server, go to Setup > select the Enable IPv4 check box and/or the Enable IPv6 check box.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8506

Message
A command to shut down the CMC was initiated.
Detailed Description
A command to shut down the CMC was initiated.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8507

Message
Extended Storage for primary CMC and secondary CMC synchronization is complete.
Detailed Description
The Extended Storage feature synchronizes data from the primary CMC removable flash media SD Card is synchronized with the secondary CMC removable flash media SD Card.
Recommended Response Action
No response action required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
Trap/EventID
8691
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8508

Message
Unable to synchronize the primary and secondary CMC removable flash media and the Extended Storage feature is not available.
Detailed Description
The Extended Storage feature is not activated if the removable flash media SD Card on the secondary CMC is not functioning properly.
Recommended Response Action
Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If errors are displayed, execute the following racadm command: "racadm cmcchangeover". 3) Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media > Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only allowed on the SD card of the primary CMC. If the problem persists, replace the card.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8509

Message
Unable to activate the extended storage feature on the secondary CMC: arg1 . The feature will be deactivated.
Arguments
arg1 = cmc number
Detailed Description
The extended storage feature is not activated if the media on the secondary CMC is no longer functional.
Recommended Response Action
Do one of the following, and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration and verify if the card on the secondary CMC displays errors. 2) Do a failover and then reprovision the card from the same GUI page. Reprovisioning is only allowed on the card of primary CMC. However, if both the options 1 and 2 fail, the card may be no longer functional.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
8689
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8510

Message
Unable to activate the extended storage feature on the secondary CMC: arg1 . The feature will return to single CMC mode.
Arguments
arg1 = cmc number
Detailed Description
This happens during promotion of extended storage feature from single CMC to dual CMC. If the media on Standby CMC is not healthy, this message is displayed and the feature returns to single CMC state.
Recommended Response Action
Do one of the following, and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration and verify if the card on the secondary CMC displays some errors. 2) Do a failover and then reprovision the card from the same GUI page. Reprovisioning is only allowed on the card of primary CMC. However, if both the options 1 and 2 fail, the card may be no longer functional.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
8689
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8511

Message
Unable to synchronize the data in the Extended Storage removable flash media in the primary and secondary CMCs.
Detailed Description
The data on the Extended Storage removable flash media SD cards is not synchronized when the CMC is unable to determine which card has the latest data.
Recommended Response Action
Disable and then enable the Extended Storage feature. Using racadm, execute the following commands: "racadm feature -d -c Extended Storage" to disable and then "racadm -a -c Extended Storage" to enable the feature. NOTE: All the data on the removable flash media SD card is erased when the feature is disabled.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
8690
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8512

Message
The Extended Storage feature activation timed out. The feature is not active.
Detailed Description
The Extended Storage feature is not activated if the removable flash media SD card on the secondary CMC does not respond within 90 seconds after activation is initiated.
Recommended Response Action
Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If errors are displayed, execute the following racadm command: "racadm cmcchangeover". 3) Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media > Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only allowed on the SD card of the primary CMC. If the problem persists, replace the card.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
8689
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8513

Message
The Extended Storage feature activation on the secondary CMC timed out. The feature is being returned to single CMC mode.
Detailed Description
The Extended Storage feature activation on the secondary CMC timed out. If the media on Standby CMC doesnt respond within 90 seconds of confirming activation the feature returns to single CMC mode.
Recommended Response Action
Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller > Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If errors are displayed, execute the following racadm command: "racadm cmcchangeover". 3) Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media > Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only allowed on the SD card of the primary CMC. If the problem persists, replace the card.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
8690
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8514

Message
Fabric mismatch is detected in the I/O Module arg1 .
Arguments
arg1 = iom slot name
Detailed Description
This error may occur due to any of the following conditions: 1) Invalid I/O Module and mezzanine card configuration, where a newly installed I/O Modules fabric type and the resident mezzanine cards fabric types do not match or are incompatible. 2) Invalid I/O Module and I/O Module configuration, where a newly installed I/O Module has a different or incompatible fabric type from an I/O Module already installed in the fabric.
Recommended Response Action
Refer to Chassis Management Controller Users Guide for additional information.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8516

Message
The I/O Module arg1 did not boot within the expected time.
Arguments
arg1 = iom slot name
Detailed Description
The I/O module may have taken more time to boot than was expected or the I/O module did not boot.
Recommended Response Action
Verify the I/O Module is turned on using CMC Web Interface or RACADM CLI and retry the operation. Otherwise, reinsert the I/O Module and retry the operation. If the problem persists, contact technical support.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
2546
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8517

Message
A double height server is detected in slot arg1 , however the server is not detected in the bottom slot.
Arguments
arg1 = slot number
Detailed Description
A double height server is detected in slot specified in the message, however the server is not detected in the bottom slot. This occurs if the server is not correctly inserted into the chassis.
Recommended Response Action
Remove the server from the chassis, check for any broken or bent pins at the rear of the server. If there is no damage, reinsert the server into the chassis.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8518

Message
Detecting Double height server in slot arg1 but the iDRAC in bottom slot arg2 is also responding.
Arguments
arg1 = slot number, arg2 = slot number
Detailed Description
the Double height server identified in the message is detected in the top slot. However, the bottom slot is also responding which should not occur if a double height server is inserted.
Recommended Response Action
Do the following: 1) Remove the server identified in the message. 2) Restart the CMC and wait for the CMC to complete the start up process. 3) Reinsert the server identified in the message. If the problem persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8519

Message
The LOM riser FRU for slot arg1 FRU ID arg2 is not functioning.
Arguments
arg1 = slot number, arg2 = fru id
Detailed Description
FRU of the LOM riser specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8520

Message
The FRU on server arg1 is not functioning.
Arguments
arg1 = slot number
Detailed Description
FRU on the server specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8521

Message
The Mezz card 1 FRU for the server arg1 is not functioning.
Arguments
arg1 = slot number
Detailed Description
The Mezz card 1 FRU for the server specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8522

Message
The Mezz card 2 FRU for the server arg1 is not functioning.
Arguments
arg1 = slot number
Detailed Description
The Mezz card 2 FRU for the server specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8523

Message
The Mezz card 3 FRU for the server arg1 is not functioning.
Arguments
arg1 = slot number
Detailed Description
The Mezz card 3 FRU for the server specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8524

Message
The Mezz card 4 FRU for the server arg1 is not functioning.
Arguments
arg1 = slot number
Detailed Description
The Mezz card 4 FRU for the server specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8525

Message
The FRU on the sleeve arg1 is not functioning.
Arguments
arg1 = slot number
Detailed Description
The FRU on the sleeve specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8526

Message
Unable to retrieve the server- arg1 CPU information.
Arguments
arg1 = slot number
Detailed Description
CMC is unable to obtain the CPU information from the server specified in the message. This occurs if there is no communication between CMC and iDRAC.
Recommended Response Action
Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
2546
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8527

Message
Unable to retrieve the server- arg1 memory information.
Arguments
arg1 = slot number
Detailed Description
CMC is unable to obtain the memory information from the server specified in the message. This occurs if there is no communication between CMC and iDRAC.
Recommended Response Action
Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
2546
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8528

Message
Unable to obtain or send link tuning or flex address data to server- arg1 .
Arguments
arg1 = slot number
Detailed Description
CMC is unable to obtain the link tuning or flex address information for the newly installed hardware (server, Input Output Module, or Mezzanine card), or is unable to send the link tuning or flex address information to iDRAC.
Recommended Response Action
Make sure that the currently installed CMC firmware is the latest. Otherwise, update the CMC with the latest CMC firmware and retry the operation.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
2546
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8529

Message
Unable to perform the requested action on the server- arg1 , because of insufficient privileges.
Arguments
arg1 = slot number
Detailed Description
The user account does not have sufficient privileges to perform the requested operation. Server Administrator privilege is required to perform the requested action.
Recommended Response Action
Use a different user account that has Server Administrator privilege, and retry the operation. For more information, contact your system administrator or service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8531

Message
Unable to perform the requested action on the Sleeve or Sled arg1 because of insufficient user privileges.
Arguments
arg1 = slot number
Detailed Description
The user account does not have sufficient privileges to perform the virtual reseat operation on the Sleeve or Sled specified in the message. The server administration privilege is required to perform a virtual reseat operation. This applies to Sleeve or Sled components.
Recommended Response Action
Use a different user account that has server administration privileges, and retry the operation. For more information, contact your system administrator about necessary privileges.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8532

Message
Unable to perform the requested action on the peripheral sled arg1 , because of insufficient privileges.
Arguments
arg1 = slot number
Detailed Description
The user account does not have sufficient privileges to perform the requested operation. Server Administrator privilege is required to perform the requested action.
Recommended Response Action
Use a different user account that has Server Administrator privilege, and retry the operation. For more information, contact your system administrator or service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8533

Message
Unable to read the FRU information, status = arg1
Arguments
arg1 = status value
Detailed Description
Unable to read the header of the extended FRU information. This can occur if there is a problem in the communication between the CMC and the server.
Recommended Response Action
Remove and reinsert the server. The CMC will retry the read operation of the FRU information. If the issue persists, contact your service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8534

Message
Unable to turn on the server arg1 because the power requirement request exceeds the power cap value.
Arguments
arg1 = slot number
Detailed Description
Unable to turn on the server specified in the message, because the available power is lesser than the requested power.
Recommended Response Action
In the CMC Web interface, verify the available power and server power requirements. If sufficient power is available, retry the operation. Otherwise, increase the power cap value.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
2546
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8535

Message
Unable to turn on High Power Management for the server arg1
Arguments
arg1 = slot number
Detailed Description
Unable to turn on the server specified in the message because of an internal CMC error.
Recommended Response Action
Reboot CMC and retry the operation. If the issue persists, reseat the server and retry the operation.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
8689
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8538

Message
Firmware version string is too long.
Detailed Description
The length of the CMC firmware version to be sent in the message from local CMC to peer CMC is too long. Under these conditions, CMC version in the message is displayed as 1.0.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8539

Message
The CMC arg1 is unable to log arg2 event to the Hardware Log.
Arguments
arg1 = slot id, arg2 = event message
Detailed Description
CMC cannot log new events to Hardware Log if Hardware Log is full. Therefore, new events are not written to the log unless older events are cleared. This issue also occurs if event logging is disabled.
Recommended Response Action
Do the following: 1) Save the Hardware Log if required. 2) Clear the Hardware Log.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8540

Message
The CMC arg1 is turned on.
Arguments
arg1 = slot id
Detailed Description
The CMC specified in the message is turned on because of a CMC insertion or due to chassis AC power on.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8541

Message
The watchdog has reset the CMC arg1 .
Arguments
arg1 = slot id
Detailed Description
The CMC specified in the message was reset by a watchdog event.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8542

Message
The CMC arg1 was restarted because of a manual reset.
Arguments
arg1 = slot id
Detailed Description
The CMC specified in the message was manually restarted.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8543

Message
The CMC arg1 has reset because the thermal threshold was exceeded.
Arguments
arg1 = slot id
Detailed Description
The CMC specified in the message has reset because of thermal issues.
Recommended Response Action
Do the following: 1) Review the Hardware Log and check if there are fans that are not functioning properly. 2) Replace the fans that are not functioning properly. 3) If all the fans are functioning, check the chassis temperature in the CMC Web Interface or by using RACADM. When the fans are functioning properly and the chassis temperature is too high, the ambient air temperature is too high or the air inlets are not receiving sufficient air.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8545

Message
Detected a missing process failover condition detected. Process = arg1 .
Arguments
arg1 = process name
Detailed Description
A firmware error has occurred causing a CMC failover. The process identified in the message was not detected. The CMC will restart automatically.
Recommended Response Action
No response action is required. If multiple failovers occur, contact your service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8546

Message
Issues identified with Process arg1 . Failover condition detected.
Arguments
arg1 = process name
Detailed Description
A firmware error has occurred in the internal firmware process identified in the message. This condition will cause a CMC failover to occur. If the issue persists, contact your service provider.
Recommended Response Action
No response action is required. A failover may result from this condition. If multiple failovers occur, contact your service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8547

Message
Missing kernel module arg1 . Failover condition detected
Arguments
arg1 = module name
Detailed Description
A firmware error occurred causing the failover. If this condition continues, a failover will result. If multiple failovers occur, contact Service.
Recommended Response Action
No response action is required. If the issue persists, contact your service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8548

Message
The active Chassis Management Controller is no longer connected to an external network.
Detailed Description
The active Chassis Management Controller is not connected to an external network for more than 25 seconds. A failover is performed if the standby CMC is connected to the external network.
Recommended Response Action
Make sure that the external network cable is connected to the active CMC and the network switch. If the issue persists, contact your service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8550

Message
The chassis health is arg1 .
Arguments
arg1 = health state
Detailed Description
If the chassis health status changes, new status is logged. The possible states are Invalid, Other, Unknown, Healthy, Non-critical, Critical, and Non-recoverable.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8551

Message
The chassis health is arg1 .
Arguments
arg1 = health state
Detailed Description
The message is displayed if the chassis health is not OK (non-critical or critical). The message after this message in the log indicates cause for the issue.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8553

Message
An internal error occurred and a failover condition is detected.
Detailed Description
An internal I2C hardware occurred and CMC initiated a failover to clear the hardware error. If the issue persists, contact your service provider..
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8554

Message
An internal network error occurred.
Detailed Description
An internal network error occurred. If none of the external sources have an issue, the CMC may have a hardware issue. If the issue persists, contact your service provider.
Recommended Response Action
Reseat the network cable and check the connectivity to the outbound switch.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8555

Message
An internal memory error has occurred and a failover condition is detected.
Detailed Description
An internal memory error occurred affecting the configuration database and CMC has initiated a failover . If the issue persists, contact your service provider.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8557

Message
The system health failover is requested. Code arg1 .
Arguments
arg1 = number
Detailed Description
The code number specified in the message is displayed after a firmware error occurs before a failover .
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8558

Message
The system health is restored.
Detailed Description
The system health has recovered from a failover condition.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8561

Message
Unable to send the email to arg1 after trying arg2 times.
Arguments
arg1 = destination, arg2 = number
Detailed Description
Unable to send the email alerts to the destination.
Recommended Response Action
Make sure to use a valid email address.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8562

Message
The log is cleared.
Detailed Description
The hardware log is cleared.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8563

Message
The KVM is mapped to the server slot arg1 .
Arguments
arg1 = slot number
Detailed Description
The KVM is mapped to the server slot number specified in the message.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8564

Message
The KVM mapping feature is disabled.
Detailed Description
The KVM is not mapped to any of the server slots.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8565

Message
KVM mapping is enabled for the server slot arg1 .
Arguments
arg1 = slot number
Detailed Description
The KVM mapping is enabled for the server slot specified in the message. The KVM cannot be mapped to this server slot.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8566

Message
KVM mapping is disabled for the server slot arg1 .
Arguments
arg1 = slot number
Detailed Description
The KVM mapping is disabled for the server slot specified in the message. The KVM cannot be mapped to this server slot.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8567

Message
The DVD drive is mapped to the server slot arg1 .
Arguments
arg1 = slot number
Detailed Description
The DVD drive is mapped to the server slot specified in the message.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8568

Message
The DVD drive mapping feature is disabled.
Detailed Description
The DVD drive is disabled and is not mapped to any of the server slots.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8569

Message
The server slot arg1 is enabled for DVD drive mapping.
Arguments
arg1 = slot number
Detailed Description
The server slot specified in the message is enabled for DVD drive mapping. The DVD drive can be mapped to this server slot.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8570

Message
The server slot arg1 is disabled for DVD drive mapping.
Arguments
arg1 = slot number
Detailed Description
The server slot specified in the message is disabled for DVD drive mapping. The DVD drive cannot be mapped to this server slot.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8571

Message
The coin cell battery in the primary CMC is not working.
Detailed Description
The coin cell battery in the primary CMC is not working. The battery needs to be replaced.
Recommended Response Action
Replace the coin cell battery in the primary CMC.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
8689
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8572

Message
The coin cell battery in CMC arg1 is not working.
Arguments
arg1 = slot id
Detailed Description
The coin cell battery in the CMC located in the slot specified in the message is not working. The battery needs to be replaced.
Recommended Response Action
Replace the coin cell battery of the standby CMC
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
8689
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8573

Message
The chassis health is arg1 .
Arguments
arg1 = health state
Detailed Description
The chassis health is critical or non-recoverable.
Recommended Response Action
Review the Chassis log or the Chassis Management Controller(CMC) SEL log for the failure or Export chassis log and SEL log and contact technical support .
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

CMC8575

Message
The RAC SSL Certificate is changed.
Detailed Description
The RAC SSL Certificate is changed.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
Trap/EventID
8691
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC     ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8576

Message
The RAC CA Certificate is changed.
Detailed Description
The RAC CA Certificate is changed.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
Trap/EventID
8691
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC     ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8577

Message
The Remote Access Controller (RAC) Kerberos Keytab is changed.
Detailed Description
The Remote Access Controller (RAC) Kerberos Keytab is changed.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
Trap/EventID
8691
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC     ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8578

Message
The Remote Access Controller (RAC) SSL Certificate and key is changed
Detailed Description
The Remote Access Controller (RAC) SSL Certificate and key is changed.
Recommended Response Action
No response action is required.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
Trap/EventID
8691
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC     ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*            

CMC8579

Message
Unable to upload the security certificate because of an Unexpected Event issue in the Remote Access Controller (RAC).
Detailed Description
The security certificate cannot be uploaded because of an Unexpected Event issue in the Remote Access Controller.
Recommended Response Action
Upload the certificate again and retry operation.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
Trap/EventID
8690
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC     ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*            

CMC8601

Message
The Chassis group arg1 is created.
Arguments
arg1 = group name
Detailed Description
The Chassis group identified in the message is created. This chassis is the leader of the group.
Recommended Response Action
No response action required.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8602

Message
The Chassis group arg1 is deleted.
Arguments
arg1 = group name
Detailed Description
The Chassis group identified in the message is deleted. This chassis was the leader of the group.
Recommended Response Action
No response action required.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8603

Message
Unable to read the FRU information from the server arg1 , status arg2 .
Arguments
arg1 = server slot number, arg2 = server status
Detailed Description
CMC cannot read the information about the FRU, because of an internal issue with the CMC and the server. Some information such as model number may not be reported. The server may not power up if the server planar FRU cannot be read.
Recommended Response Action
Remove and reinsert the server. The Chassis Management Controller will retry the read operation of the FRU information. If the issue persists, contact your service provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8604

Message
The FRU on storage sled arg1 is not functioning.
Arguments
arg1 = slot number
Detailed Description
The FRU on the storage sled specified in the message is not functioning or CMC is unable to read it.
Recommended Response Action
Do the following: 1) Reinsert the specified storage sled or virtual reseat the sled 2) Reset CMC and wait for a few minutes for the CMC to finish restarting. If the issue persists, contact your service provider.
Category
System Health (CMC = Chassis Management Controller)
Severity
Severity 1 (Critical)
Trap/EventID
2545
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

CMC8605

Message
The chassis health state is no longer OK and is currently arg1 .
Arguments
arg1 = health state
Detailed Description
The chassis health state is no longer OK and is currently the state identified in the message. Actions should be taken to resolve any outstanding issues so that the chassis health state will return to OK.
Recommended Response Action
Review the Chassis log or the Chassis Management Controller(CMC) SEL log for any outstanding issue(s) and resolve any issues found by performing the recommended response action for each issue found. If the issue persists, export the chassis log and CMC SEL log and contact your support provider.
Category
Audit (CMC = Chassis Management Controller)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

CMC8700

Message
The I/O Module in slot arg1 is configured in secure IOM mode.
Arguments
arg1 = slot number
Detailed Description
I/O Module identified in the message cannot be managed from the CMC when the I/O Module is configured in secure IOM mode.
Recommended Response Action
No response action is required.
Category
Configuration (CMC = Chassis Management Controller)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\