Hello. In this video we will go over clearing device errors in PowerFlex using the Presentation Server.
To begin with, we will need to log into the Presentation Server using the username „admin“ and key in the admin password Once logged in, we will go to the bottom left side of the screen to check for the ALERTS tab.
Click on the ALERTS tab and clear out any filters that may be present at that time to see all the alerts. On the screen here we see Drive SDC is in an error state.
We will click on the ACKNOWLEDGE button to acknowledge this alert first. Now before we move on to clear the device errors, we need to verify if the particular Drive is in healthy state from the hardware end. For this we can log into the iDRAC of this particular node and check for the drive status.
If we have verified that the drive is healthy from the hardware end, we can proceed with clearing the errors. To clear the errors, we can click on the name of the drive that is in an error state.
That will directly take us to the issued Drive. We can click on the check box that is present just next to the drive name, which will select the stripe.
And click on more option from top right of the screen to see the drop-down menu. Here we see CLEAR ERRORS option. We will click on CLEAR ERRORS and acknowledge again on clear errors to clear this device error.
We have successfully cleared the device errors, but in order to verify if the alerts have cleared or not, we can go back to the ALERTS, clear out the filters again and see if there are any alerts present. Here we don't see any alerts.
To verify again from the SDS level, we can go to the SDS with the issue Drive. List all the devices that are present on the SDS and check the status for all the drives present.