LSI MegaRAID SAS 9460-16i Controller Firmware

Restart required Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package contains the firmware for LSI MegaRAID SAS 9460-16i controller. The firmware enhances the performance and reliability of Windows-based systems with storage devices.
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

- Fixed the issue where an error message is displayed when the system resumes from sleep mode. This issue occurs when LSI 9441 card is connected, and LSI firmware version is v7.12.
- Fixed the performance issue with LSI 9440-8i with firmware 50.5.0-1129 or later when Patrol Read option is enabled.
Read More

Version

51.12.0-3411, A06

Release date

26 Mar 2021

Download Type

Firmware

Category

SAS RAID

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats

File Format: ZipPack External
File Name: 9460_FW_MR7.12_ZPE.exe
File Size: 8.67 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
a78a1b2f3fa94939806aa74b1966ad8b
SHA1:
5cbf46724eca48eb2de341bb5679e1b649b7dda5
SHA-256:
b791a0bfd502e08694820ccbd467d1c2cacb0095caa22bb8e3be7cd4f14cc863

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
9460-16i Storage Controller for Precision Workstations
MegaRAID SAS 9460-16i
Download and Extract
1. Click Download File.
2. When the File Download window is displayed, click Save to save the file to your hard drive.
3. Extract the files from the .zip.
4. Follow the instructions in the Readme.txt within the .zip file.

Installation

UEFI
1. Run the storcli.efi from the UEFI shell.
2. To update, use the following command in the UEFI shell and reboot the system after completion:
storcli.efi /c0 download file = 9460-16i_nopad.rom
3. Repeat the step if you have more than one controller in your system by updating /c0 to /c1, /c2, and so on.

Windows 32-bit and 64-bit
1. Open an elevated command prompt window by using the Run as administrator option.
2. For 32-bit systems, run the storcli.exe and for 64-bit systems, run storcli64.exe.
3. To update, run the following command and reboot the system after completion:
For Windows 32-bit-storcli.exe /c0 download file = 9460-16i_nopad.rom
For Windows 64-bit-storcli64.exe /c0 download file = 9460-16i _nopad.rom
4. Repeat the step if you have more than one controller in your system by updating /c0 to /c1, /c2, and so on.

Enabling the NVME profile
Note: With this release, SAS/SATA and NVMe drives can be used simultaneously if the profileID is set to 11.

UEFI
1. Run the following command to change the card to NVMe profile:
storcli.efi /c0 set profile profileid=13
2. Run the following command to change the card back to SAS/SATA profile:
storcli.efi /c0 set profile profileid=10
3. Run the following command to check the profile:
storcli.efi /c0 show profile

Windows 32-bit
1. Run the following command to change the card to NVMe profile:
storcli.exe /c0 set profile profileid=13
2. Run the following command to change the card back to SAS/SATA profile:
storcli.exe /c0 set profile profileid=10
3. Run the following command to check the profile:
storcli.exe /c0 show profile

Windows 64-bit
1. Run the following command to change the card to NVMe profile:
storcli64.exe /c0 set profile profileid=13
2. Run the following command to change the card back to SAS/SATA profile:
storcli64.exe /c0 set profile profileid=10
3. Run the following command to check the profile:
storcli64.exe /c0 show profile

Drivers help and tutorials