Kioxia BD0D for PM6 for model number(s) KPM6WRUG15T3, KPM6WRUG7T68, KPM6WRUG3T8, KPM6WRUG1T92, KPM6WRUG960G, KPM6WVUG7T68, KPM6WVUG3T84, KPM6WVUG1T92, KPM6WVUG960G

Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
Kioxia BD0D for PM6 for model number(s) KPM6WRUG15T3, KPM6WRUG7T68, KPM6WRUG3T8, KPM6WRUG1T92, KPM6WRUG960G, KPM6WVUG7T68, KPM6WVUG3T84, KPM6WVUG1T92, KPM6WVUG960G
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
1)Host CMD timeout occurs when the FW download is executed repeatedly while the host I/O CMDs are processing. 2)During the power on sequence, if a DRAM error occurs when reading system area data that is stored in NAND Flash, the drive may fail to come ready. 3)BCRC (HRT-ORT issue) 4)A firmware issue was detected in internal test. It can result in a Silent Data Error if power is removed while a drive is processing a specific combination of read/write commands using Non 4KB-aligned access.
Read More

Version

BD0D, A00

Release date

03 Jun 2022

Download Type

Firmware

Category

SAS Drive

Importance

Urgent
Dell Technologies highly recommends applying this important update as soon as possible. The update contains critical bug fixes and changes to improve functionality, reliability, and stability of your Dell system. It may also include security fixes and other feature enhancements.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: SAS-Drive_Firmware_376CY_WN64_BD0D_A00.EXE
File Size: 11.6 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
ec60995ad8bb207b1a3dd960191aa5b0
SHA1:
93ea95298b011b8302899936e5488738135d9b3b
SHA-256:
dab2e2bb9642b691c70b215ca6e998d15679c5bddd1a14031d52b57b15622dbf

File Format: A GnuPG file which contains a cryptographic signature
File Name: SAS-Drive_Firmware_376CY_LN64_BD0D_A00.BIN.sign
File Size: 226 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
e072fbf1a9b7a163c5098e895d4ac240
SHA1:
e47c588fed24f78452d12e44da611875caa8f348
SHA-256:
103bb9a0fa88e8cdaf68aeb79f995a53f6e71eda23042a069be63f3e720af25a

File Format: Update Package for Red Hat Linux
File Name: SAS-Drive_Firmware_376CY_LN64_BD0D_A00.BIN
File Size: 3.69 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
52df466dc148e97d656c48f62db57bfa
SHA1:
dca5b08bc30fc74c40d1fc173770270abde6dd87
SHA-256:
a80f95db1f6c0da0aac3eade0cf621416c70043fbfbf933b233bc0cd397d91a6

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.

This update will run on drives remaining in a RAID set that is in a Offline state.

There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Suse Linux ES 10
Linux
Windows Server 2012
Not Applicable
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 7
Red Hat® Ent Linux 5
Red Hat® Enterprise Linux 8
Windows Storage Server 2012 R2
Novell SuSE Linux ES 10
SuSE Linux Desktop 11
SUSE Linux ES 12
SuSE Linux ES 15
Windows Server 2012 R2
Windows Server 2008 x86
Windows Server 2003
Windows Server 2019 LTSC
Windows Server 2022 LTSC
Windows Server 2008 R2
Windows Storage Server 2012
Windows Server 2016
Windows Server 2003 x64
VMware ESXi 6.5
VMware ESXi 6.7
VMware ESXi 7.0
PM6 1WPD SSDR,1.9T,2E,FS12,2.5,X,P6,EC Model Number: KPM6WRUG1T92 Regulatory Model Number: KPM6WRUG1T92 Vendor PN: SDFUS75DAB
PM6 1WPD SSDR,15.T,2E,FS12,2.5,X,P6,EC Model Number: KPM6WRUG15T3 Regulatory Model Number: KPM6WRUG15T3 Vendor PN: SDFUS71DAB
PM6 1WPD SSDR,3.8T,2E,FS12,2.5,X,P6,EC Model Number: KPM6WRUG3T84 Regulatory Model Number: KPM6WRUG3T84 Vendor PN: SDFUS74DAB
PM6 1WPD SSDR,7.6T,2E,FS12,2.5,X,P6,EC Model Number: KPM6WRUG7T68 Regulatory Model Number: KPM6WRUG7T68 Vendor PN: SDFUS73DAB
PM6 1WPD SSDR,960G,2E,FS12,2.5,X,P6,EC Model Number: KPM6WRUG960G Regulatory Model Number: KPM6WRUG960G Vendor PN: SDFUS76DAB
PM6 3WPD SSDR,1.9T,2E,FS12,2.5,X,P63,EC Model Number: KPM6WVUG1T92 Regulatory Model Number: KPM6WVUG1T92 Vendor PN: SDFUR85DAB
PM6 3WPD SSDR,3.8T,2E,FS12,2.5,X,P63,EC Model Number: KPM6WVUG3T84 Regulatory Model Number: KPM6WVUG3T84 Vendor PN: SDFUR84DAB
PM6 3WPD SSDR,7.6T,2E,FS12,2.5,X,P63,EC Model Number: KPM6WVUG7T68 Regulatory Model Number: KPM6WVUG7T68 Vendor PN: SDFUR83DAB
PM6 3WPD SSDR,960G,2E,FS12,2.5,X,P63,EC Model Number: KPM6WVUG960G Regulatory Model Number: KPM6WVUG960G Vendor PN: SDFUR86DAB
Dell Update Package instructions for Linux DUP (RHEL/SLES/Ubuntu):
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and run the update by executing
"./ SAS-Drive_Firmware__LN__A00.BIN " from the shell.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions:

Download the latest GnuPG Signature of Dell Update Package from support.dell.com.

1. Browse to the location where you downloaded the file.
2. Read over the release information presented in the dialog window.
Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, SAS-Drive_Firmware__LN__A00.BIN.Sign.

Drivers help and tutorials