Download Files
File Format: Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
File Name: BIOS_0R1N0_WN64_2.19.1.EXE
File size: 28.21 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: 195e1448eb262e9768324cc71c357625
SHA1: 6902656aa9ffa23ac916b5ef5fcf9eef3e709ab1
SHA-256: 19e267a623a753f6eb2daf3e8ab48de4a6da886d3ae7784c73d1d96d6e94fe90
File Format: The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
File Name: BIOS_0R1N0_LN64_2.19.1.BIN.sign
File size: 226 Bytes
To ensure the integrity of your download, please verify the checksum value.
MD5: 8d54c046f6185112036ad28f2b715d6b
SHA1: ba1ea00873d9960ab11eb25be9b0ed5470d32af4
SHA-256: 02b09530c6c24c0756907bf1ce5246b22cf86295efd4a4fe77d97987849123e5
File Format: This file contains compressed content that can be executed from the EFI Shell or EFI Boot Manager. Download the file to the EFI partition on a removable media device. Insert the removable media, then reboot the system and run the program from the EFI Shell or EFI Boot Manager.
File Name: M640-021901.efi
File size: 19.15 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: f6946b9b95b3289761d3161107146a63
SHA1: 7cf3eba1ccaa3bf5efe03c0ca09df2e99c9efb7d
SHA-256: c99cc57aba266e18a34d0d1029bb504e353cafc2a0b8b62d9771a8a71b214ff7
File Format: This format consists of an archive of PDF files used to provide help and procedural information to the customer. It is necessary to install the Adobe Acrobat Reader first to view the files in this archive.
File Name: M640_FC640_M640_VRTX_BIOS 2.19.1_RN.pdf
File size: 285 KB
To ensure the integrity of your download, please verify the checksum value.
MD5: 76d457b39d80a235a2fa6d2d3c49ae75
SHA1: 94c5cd4fd343bc4f8af79816d5b8f3d3b8fbd42a
SHA-256: 605beba09117e161b9836f44e5fccb0a4dd7dddf9a9b32b0a088e8f4f600e4e1
File Format: Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
File Name: BIOS_0R1N0_LN64_2.19.1.BIN
File size: 23.27 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: 720fa549e63ad3ca394386a98ffb8c0e
SHA1: 641c9ec9080ab1d1b5b41a4d2e1afdc634bf9edc
SHA-256: ceccba17cd75495e3589ab958fe2af99db43ba7c9feb80c26a6683e68657d426
Fixes & Enhancements
Fixes:
- Fix system crashes if a bootloader (grub, ipxe) attempts to open UEFI network driver exclusively.
Enhancements:
- Updated the following:
* Processor and Memory Reference Code for the second-generation Intel Xeon Processor Scalable Family to IPU 2023.3.
* The Integrate Intel Purley Refresh PV Candidate Reference Code Version to 628P50.
* Processor Microcode to version 0x3604 for the second-generation Intel Xeon Processor Scalable Family.
* Processor Microcode to version 0x7006 for Intel Xeon Processor Scalable Family.
* Updated SPS to SPS_E5_04.01.05.002.0 (IPU 23.3) for Purley Refresh.
* S140 Software RAID firmware to version 5.10.0-0001.
* Integrated Dell Remote Access Controller (iDRAC) HII settings engine to version 5.00.00.15.
Important Information
- Rolling back to a previous BIOS from 2.14.2 will cause a TXT trusted boot failure with TXT enabled. Since the Intel ACM's SVN (Security Version Number) was increased in BIOS 2.14.2 to address the Security Vulnerabilities CVE-2021-0559, CVE-2021-33123, CVE-2021-33124. The purpose of incrementing the SVN is to prevent executing an older ACM with the vulnerabilities.
* The INTEL ACM's SVN was also increased in the BIOS 2.9.4 since the 1st BIOS revision of this platform as well.
- When using an Update Package (DUP) file or the UEFI Shell command (an EFI file) to update the BIOS version, the process takes longer duration. To resolve this issue, do one of the following:
* Update the BIOS version using an Out-of-Band (OoB) tool such as iDRAC--use GUI or run the RACADM command. See the iDRAC User's Guide or RACADM CLI Reference Guide available on the support site.
* Reduce the system memory capacity by physically removing the memory modules and perform the BIOS update and retry the operation.
- When one or more PCIe devices are installed on the system and if the cards require more of limited legacy I/O resources, the system might modify the I/O resources causing it to restart automatically. The UEFI0256 error message is logged, and the system does not allocate the PCIe resources required. To resolve this issue, do one of the following:
* Remove the PCIe cards from the system that are not used to free up the legacy I/O allocation and provide more I/O allocation space.
* From the System Setup menu, disable to PCIe cards that are not used to free up the legacy I/O allocation.
- When one or more PCIe devices are installed on the system and if the cards require more of Memory-Mapped I/O (MMIO) resources, the system might modify the MMIO resources causing it to restart automatically. The UEFI0256 error message is logged, and the system does not allocate the required PCIe resources required. To resolve this issue, do one of the following:
* Remove the PCIe cards from the system that are not used to free up the MMIO allocation.
* From the System Setup menu, enable the Memory Mapped I/O above 4GB option to free up the MMIO allocation.
NOTE: Before working inside your system, follow the safety guidelines listed in the Safety Instructions topic in the Installation and Services Manual of your respective server model available on the support site.
Supported Operating Systems
Installation instructions
Dell Update Package Instructions for DRMK
Download
1. Click the "Download" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
NOTE: You must provide a DOS bootable media, such as a USB key. This executable file does not create the DOS system files.
1. Browse to the location where you downloaded the file.
2. Update the name of the file to DOS recognizable format (8.3). If you do not update the filename to 8.3 format, the filename will be truncated to 8.3 format.
3. Copy the file to the bootable device.
4. Boot the system to DOS by using the bootable device.
5. Run the executable under DOS. Follow the instructions provided by the flash utility.
-------------------------------------------------------------------------------
Dell Update Package Instructions for EFI
Download
1. Click the "Download" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
You can update the BIOS using a UEFI shell bootable media, such as a USB key.
1. Copy the file to the bootable device with UEFI shell.
2. Boot the system to UEFI shell by using the bootable device.
3. Run the executable (.efi) under the UEFI shell. Follow the instructions provided by the flash utility.
You can also load this executable directly from BIOS Boot Manager without a UEFI shell bootable media.
1. Copy the file to a USB device
2. Plug in the USB device and press F11 during POST to enter BIOS Boot Manager
3. Navigate to the System Utilities menu and select BIOS Update File Explorer
4. Select the USB device and navigate through the directory contents to find the executable (.efi)
5. Launch the executable and follow the instructions provided by the flash utility.
--------------------------------------------------------------------------------
Dell Update Package Instructions for Linux DUP:
Download
1. Click the "Download" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Read over the release information presented by executing the "./[model]_BIOS_LX_[revision].BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
4. Run the update by executing "./[model]_BIOS_LX_[version].BIN" from the shell.
5. Follow the remaining prompts to perform the update.
--------------------------------------------------------------------------------
Dell Update Package Instructions for Windows Dup:
Download
1. Click the "Download" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.
---------------------------------------------
GnuPG Signature of Dell Update Package Instructions:
Download
1. Click the "Download" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.
Installation
1. Import the Dell public key. (You only need to do once on your system.)
2.Verify the Dell Update Package by using its signature file, [model]_BIOS_LX_[version].BIN.sign
Applies to
PowerEdge M640/FC640/M640-VRTX BIOS