Download Files
File Format: This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation.
File Name: 9460_FW_MR7.8.1_ZPE.exe
File size: 7.64 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: 4b91d0fe50a5a9ddeb5fcad8b7729efb
SHA1: af09c8c0f4434dcd15b5ba88ee0d4572362cbafe
SHA-256: fe770761610e5acd32099686dc35b25ccb2870b966b293d5340647c727873f05
Fixes & Enhancements
- Added support for NVMe passthrough in UEFI mode.
- Added support for mixed mode. Mixed mode allows you to use SAS/SATA drives, and NVMe drives simultaneously.
Supported Operating Systems
Installation instructions
Download and Extract
1. Click Download to download the file.
2. When the File Download window is displayed, click Save to save the file to your hard drive.
3. Extract the file from the .zip.
4. Follow the instructions in the Readme.txt within the .zip file.
Installation
UEFI
1. Run the storcli.efi from the UEFI shell.
2. To update, use the following command in the UEFI shell and reboot the system after completion:
storcli.efi /c0 download file = 9460-16i_nopad.rom
3. Repeat the step if you have more than one controller in your system by updating /c0 to /c1, and so on.
Windows 32-bit and 64-bit
1. Open an elevated command prompt window by using the Run as administrator option.
2. For 32-bit systems, run the storcli.exe and for 64-bit systems, run storcli64.exe.
3. To update, run the following command and reboot the system after completion:
For Windows 32-bit - storcli.exe /c0 download file = 9460-16i_nopad.rom
For Windows 64-bit - storcli64.exe /c0 download file = 9460-16i_nopad.rom
4. Repeat the step if you have more than one controller in your system by updating /c0 to /c1, /c2, and so on.
Enabling the NVMe profile
Note: ProfileID=11 is used only NVMe and ProfileID=13 is used for Mixed mode to use SAS/SATA and NVMe simultaneously.
UEFI
1. Run the following command to change the card to NVMe profile:
storcli.efi /c0 set ProfileID=11
2. Run the following command to change the card back to SAS/SATA profile:
storcli.efi /c0 set ProfileID=10
3. Run the following command to check the profile:
storcli.efi /c0 show profile
Windows 32-bit
1. Run the following command to change the card to NVMe profile:
storcli.exe /c0 set ProfileID=11
2. Run the following command to change the card back to SAS/SATA profile:
storcli.exe /c0 set ProfileID=10
3. Run the following command to check the profile:
storcli.exe /c0 show profile
Windows 64-bit
1. Run the following command to change the card to NVMe profile:
storcli64.exe /c0 set ProfileID=11
2. Run the following command to change the card back to SAS/SATA profile:
storcli64.exe /c0 set ProfileID=10
3. Run the following command to check the profile:
storcli64.exe /c0 show profile
Applies to
9460-16i Storage Controller for Precision Workstations
MegaRAID SAS 9460-16i