Toshiba EE06 for model number(s) AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.

Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This release contains firmware version EE06 for Toshiba drives. Vendor model numbers AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
- Change the DOW setting value from 1Dh to 1Eh for AL15SE ATI issue.
- If HDD receive command while HDD is executing Read Retry Step 50, HDD may execute internal reboot and report sense 06-29-04(dell) or 04-29-04(emc).
- 512e and 4k format may become long latency due to DRAM management. Temporarily some DRAM data for user is not used for media cache writing called PWC in the cycle. Full DRAM data for user will be used in case of PWC.
- Support new DEFT function with ENG0011851_(DEFT)_A05 draft3
- Apply a countermeasure of HFW issue on AL14SX TCRDT.
- In case of read command for the same write LBA address following to long consecutive sequential write commands (no other command comes during the write), the HDD sends wrong data from cache area. The boundary of write is one-64th of the HDD capacity. (i.e. HDD capacity=1.8GB, boundary=28MB=54,942,430sectors)
-If HDD detects Logical Block Reference tag check Failed in an READ command, HDD reports sense code 03-11-02 instead of 0B-10-03.
(4Kn and PI type 2 format HDD only)
- In case command aging timer expire and I T nexus loss occurs at the same time, HDD retry to execute the command expired by aging timer, even if the command has already aborted by I T nexus loss. As the result, the HDD report sense code, 06-29-04.
- When NOTIFY(Enable Spin Up) comes, the drive may not be able to start spinning up and report the sense, 02_04_11.
- If the HDD lost power supply while the drive is executing retry of ATI, one write splice sector may be remained. Please refer the white paper.
- When HDD receive NOTIFY (Enable SpinUp) and STAT STOP UNIT command, it starts motor spindle up. The HDD may report sense 02/04/02 instead of 02/04/01 if MODE SENSE and MODE SELECT command unexpectedly come before HDD ready.
Read More

Version

EE06, A00

Release date

11 Dec 2019

Download Type

Firmware

Category

SAS Drive

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: SAS-Drive_Firmware_GC3VM_WN64_EE06_A00.EXE
File Size: 10.15 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
0b9c33e082442446245e1edd92a75065
SHA1:
175367ce7af0a74653d510d820608ae8d357786e
SHA-256:
240ba3aba62cc8cc841d701349bb72873d069b2c4c77ba9b17248c5dcb5b0a7f

File Format: A GnuPG file which contains a cryptographic signature
File Name: SAS-Drive_Firmware_GC3VM_LN_EE06_A00.BIN.sign
File Size: 226 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
cf9515598e2eec6f525ddcf6b0c3b79b
SHA1:
d1418b12a7636c540ca4b727150183cbfdd11a61
SHA-256:
1234ae9e6895d0138ac55551567c73793d8b7bc9e8c1352d0b8e71548d5e8a9c

File Format: Update Package for MS Windows 32-Bit
File Name: SAS-Drive_Firmware_GC3VM_WN32_EE06_A00.EXE
File Size: 8.95 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
dd6235d47551cd4d637fd7e6fec55cc1
SHA1:
df7b92dc2b21ac6cc732fbe1a40f0222e8c0a901
SHA-256:
376aa35f4be28023a5c2343569a33ea7608248654de31b72314f04f6acec6903

File Format: Update Package for Red Hat Linux
File Name: SAS-Drive_Firmware_GC3VM_LN_EE06_A00.BIN
File Size: 6.15 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
18e5a0e1bd51557922a09731220e8c18
SHA1:
51e6a0c4d817e69be5656d642795d3e57e32ff78
SHA-256:
8e336fd2dcc65ec15d3085c79bb7bb813be8a804173c0b5712c72a5e0bc740b1

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.

This update will run on drives remaining in a RAID set that is in a Offline state.

There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Suse Linux ES 10
Windows Server 2012
Not Applicable
Red Hat® Ent Linux 5.2
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 7
Red Hat® Ent Linux 5
SUSE Linux ES 12
Windows Server 2012 R2
Windows Server 2008 x86
Windows Server 2008 R2
Windows Server 2016
TOSHIBA AL14SX ISE 2.5 300GB SAS12 15K 512N Model Number: AL14SXB30ENY Regulatory Model Number: TBD Vendor Number: TBD
TOSHIBA AL14SX ISE 2.5 600GB SAS12 15K 512N Model Number: AL14SXB60ENY Regulatory Model Number: TBD Vendor Number: TBD
TOSHIBA AL14SX ISE 2.5 900GB SAS12 15K 512N Model Number: AL14SXB90ENY Regulatory Model Number: TBD Vendor Number: TBD
TOSHIBA AL14SX ISE 600GB 2.5 SAS12 15K 4096n Model No: AL14SXB60EAY Regulatory Model No: TBD Vendor PN: TBD
TOSHIBA AL14SX ISE 900GB 2.5 SAS12 15K 4096n Model No: AL14SXB90EAY Regulatory Model No: TBD Vendor PN: TBD
1. Click the 'Download Now' link to download the file.
2. When the File Download window appears, click 'Save' to save the file to your hard drive.

Installation

1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.

Drivers help and tutorials