Do not turn off your computer or disconnect from the power source while updating the BIOS as this could harm your computer. During the update, your computer will restart and you may briefly see a black screen.

Before updating, please read the installation instructions and important information noted below.

Dell EMC Server BIOS PowerEdge MX840c Version 2.8.2

Restart required Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
- Fixed an industry-issue seen on BIOS versions 2.6.4 through 2.8.1 where the system may reset during power-on at the time "Configuring Memory" is displayed on the boot screen. The issue is applicable to DDR4 and NVDIMM-N memory configurations.
- Updated the "Processor and Memory Reference Code" for the second-generation Intel Xeon Processor Scalable Family to IPU 2020.1.
- Enhancement to address the security vulnerabilities (Common Vulnerabilities and Exposures-CVE) such as CVE-2020-0545, CVE-2020-0548, and CVE-2020-0549.
For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced features sections.
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
Fixed an industry-issue seen on BIOS versions 2.6.4 through 2.8.1 where the system may reset during power-on at the time "Configuring Memory" is displayed on the boot screen. The issue is applicable to DDR4 and NVDIMM-N memory configurations.
The following are included in 2.8.2 that were released in previous BIOS versions that are no longer available for download.
- Issue with the "Monitor/MWait" option in System Profile Settings on 2-socket servers, remaining enabled after selecting disable.
- Issue with "CPU Domain Power Limiting" not capping to target values.
- Issue with MSR 0x1AD which interfered with the new Turbo Ratio Limits has been fixed, without impacting the factory default settings.
- Added the "Balanced Memory Mode" option under "Intel Persistent Memory Performance" in System Profile setting.
- Issue with the memory capacity changing when "Node Interleaving" or "Sub NUMA Cluster" is enabled.
- Fixed an issue with Maximum Payload size because it resulted in a Purple Screen of Death (PSoD) in VMware ESXi when an NVMe drive is hot plugged in certain configurations.
- Fixed an issue where there was an improper functioning of the MSR 0x1AD (TURBO_RATIO_LIMITS_RATIOS) register.
- Fixed other miscellaneous issues.

Enhancements:
The following are included in 2.8.2 that were released in previous BIOS versions that are no longer available for download.
- Added an option in "DRAM Refresh Delay" in Memory Settings, to disable refresh postponement.
- Updated the "Processor and Memory Reference Code" for the second-generation Intel Xeon Processor Scalable Family to IPU 2020.1.
- The S140 firmware is updated to 5.5.2-0006.
- Improved the performance of 4-socket servers by adding "FastGo" and "IRQ Throttle" under Processor Settings in System BIOS.
- The memory self-healing feature is added to perform memory self-healing after an uncorrectable error (MEM 0001) or burst of correctable errors (MEM 8000). Memory self-healing for a MEM 0001 event will execute automatically, but for a series of MEM 8000 events, self-healing is initiated after a system restart.
- Updated the Processor Microcode to version 0x2F00 for the second-generation Intel Xeon Processor Scalable Family.
- Updated the Processor Microcode to version 0x69 for the Intel Xeon Processor Scalable Family.
- Updated the Intel Management Engine firmware to version 04.01.04.381.
- Updated the BIOS ACM (authenticated code module) to version 1.7.3.2019.07.12.
- Updated to support the Apache Pass (Optane DC Persistent Memory) version to 1.0.0.3497.
- Enhancement to address the security vulnerabilities (Common Vulnerabilities and Exposures-CVE) such as CVE-2020-0545, CVE-2020-0548, and CVE-2020-0549.
Read More

Version

2.8.2, 2.8.2

Release date

09 Sept 2020

Download Type

System BIOS

Category

BIOS

Importance

Urgent
Dell Technologies highly recommends applying this important update as soon as possible. The update contains critical bug fixes and changes to improve functionality, reliability, and stability of your Dell system. It may also include security fixes and other feature enhancements.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: MX840c_BIOS_H8MX2_WN64_2.8.2_02.EXE
File Size: 27.39 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
8b4a094fc11f156456dbd07c02e8b38c
SHA1:
369abdbdd84df1f21ba57e5daf3225baa618b0fa
SHA-256:
033eede910817fca7331743868b24acda6c505f7aff8d91621cb6e14a551bd5f

File Format: A GnuPG file which contains a cryptographic signature
File Name: MX840c_BIOS_H8MX2_LN_2.8.2_02.BIN.sign
File Size: 226 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
99d063549aa9d82ed304b09a21ce9240
SHA1:
dc723cc6722b8587f837f1bfe0c2a52495ab2928
SHA-256:
ad8ca79506a48feb683dbb02d58e54be3b638dc7c9f0bc9a3bb1957a754691c5

File Format: A self-extracting file for use in 64-bit machines
File Name: MX840c-020802.efi
File Size: 19.35 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains compressed content that can be executed from the EFI Shell or EFI Boot Manager. Download the file to the EFI partition on a removable media device. Insert the removable media, then reboot the system and run the program from the EFI Shell or EFI Boot Manager.
To ensure the integrity of your download, please verify the checksum value.
MD5:
9688fef463467789cb9d954eb019d6ec
SHA1:
eb3f014c9118788d50456a78843a5d7af33dd76b
SHA-256:
e61e2056fa7f75e56dd8d2deb140c3dcb52a67bca33ea6bef1237a72a19fd46a

File Format: An archive of PDF files to provide help and procedural information to the customers
File Name: MX840c_BIOS.2.8.2_RN.pdf
File Size: 155.72 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This format consists of an archive of PDF files used to provide help and procedural information to the customer. It is necessary to install the Adobe Acrobat Reader first to view the files in this archive.
To ensure the integrity of your download, please verify the checksum value.
MD5:
8db584b745c974302946909c2b845ecb
SHA1:
dfa4316b502b9f9845c444adf7946b6ceb86e8a3
SHA-256:
4d883e71ecd84b47e8787396c79294cab0319d0658a8bd7efc565d1dcb985b5e

File Format: Update Package for Red Hat Linux
File Name: MX840c_BIOS_H8MX2_LN_2.8.2_02.BIN
File Size: 28.75 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
dffe62434d1c87a4945542f8566ea7a6
SHA1:
31a379278912263eb49b4cff28ed2a55ec9e57e6
SHA-256:
a8db9d6f943ee55e337846c57520eecbf536c1d1eccc6d02c640567f41dc6a99

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
When you try updating a BIOS version either under OS (by using an Update Package (DUP)) or under UEFI Shell (a .efi file), the system may take more time to complete the BIOS update process (in case of a system that has 14 TB memory, it takes around 30 minutes to complete the BIOS update process under Windows Server 2016). There are two ways to work around this issue:
- Use an out-of-band BIOS update method--IDRAC Graphical User Interface (GUI) or RACADM Command Line Interface (CLI) command.
- Physically reduce the memory capacity by removing a few memory modules (and thus improve the speed of the BIOS update process), and then try again.

When you try installing one or more PCIe devices on the system and if the cards require more limited legacy I/O resources, then the system may adjust the legacy I/O resources between the stack and the reboot system automatically. If the system fails during the allocation of PCI resources, then a UEFI0256 error message is logged. You can perform one of the following actions and retry the operation:
- Remove unused PCIe card to free up legacy I/O space.
- Go to System Setup and disable unused PCIe card to free up legacy I/O space.
PowerEdge BIOS
Dell EMC Update Package Instructions for EFI
Download
1. Click the "Download Now" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
You can update the BIOS using a UEFI shell bootable media, such as a USB key.
1. Copy the file to the bootable device with UEFI shell.
2. Boot the system to UEFI shell by using the bootable device.
3. Run the executable (.efi) under the UEFI shell. Follow the instructions provided by the flash utility.

You can also load this executable directly from BIOS Boot Manager without a UEFI shell bootable media.
1. Copy the file to a USB device
2. Plug in the USB device and press F11 during POST to enter BIOS Boot Manager
3. Navigate to the System Utilities menu and select BIOS Update File Explorer
4. Select the USB device and navigate through the directory contents to find the executable (.efi)
5. Launch the executable and follow the instructions provided by the flash utility.
----------------------------------------------------------------------
Dell EMC Update Package Instructions for Linux DUP:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Read over the release information presented by executing the "./[model]_BIOS_LX_[revision].BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
4. Run the update by executing "./[model]_BIOS_LX_[version].BIN" from the shell.
5. Follow the remaining prompts to perform the update.
----------------------------------------------------------------------
Dell EMC Update Package Instructions for Windows Dup:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.
----------------------------------------------------------------------
GnuPG Signature of Dell EMC Update Package Instructions:
Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.
Installation
1. Import the Dell EMC public key. (You only need to do once on your system.)
2. Verify the Dell EMC Update Package by using its signature file, [model]_BIOS_LX_[version].BIN.sign.

Need help with BIOS issues?

Find a solution in Dell's BIOS troubleshooting guide

Drivers help and tutorials