Seagate TS27 for model number(s) ST1800MM0018..

Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This release contains firmware version TS27 for Seagate drives. Vendor model numbers ST1800MM0018..
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
-Fix an issue where incorrect value for Current Phy Capabilities is returned after FW download
-Fix an issue where 02/041B is reported to HARD_RESET during Sanitize operation
-Fix an issue where HARD_RESET can be missed intermittently
-Fix an issue where 03/31/00 can result on power cycle or power on
-Fix an issue where SAS speed negotiation can fail shortly after power on
-Fix an issue where drive transition to IDLE_A even when IDLE_A is disabled
-Fix an issue where drive does not transition to expected power state within set time
-Fix an issue where 05/26/99 is reported in response to Mode Select command
-Fix an issue where 04/44/00 is reported during seq. writes
-Fix issues related to Persistent Reservation feature support
-Fix issues where assert event can result
-Fix issues where command timeout can result
-Fix an issue where IOEDC error can result
-Fix an issue where bus hang event can result

Enhancements:
-Performance imrpvoements for certain workload scenarios
-Improve status reporting/logging accuracy
-Improvements for general interface protocol compliance
Read More

Version

TS27, A00

Release date

31 Mar 2017

Download Type

Firmware

Category

SAS Drive

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: SAS-Drive_Firmware_2XY5D_WN64_TS27_A00.EXE
File Size: 13.72 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
917b0c3f90e23e1f8ac18b89079cda61
SHA1:
7a3ff0c23115b484f60e6bb3aea80ffb0980f559
SHA-256:
eacd984412321e626f0fcb87e3b17e50ff49d53ddcc5419a4f35632ee48d37e6

File Format: A GnuPG file which contains a cryptographic signature
File Name: SAS-Drive_Firmware_2XY5D_LN_TS27_A00.BIN.sign
File Size: 194 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
e08763e4f4af33d8f8393928630302c1
SHA1:
e0a1a79a755001396f30cff54df7690cf133f84e
SHA-256:
3d9b8f27edde21dd77522a30e1810a5557fd370f9eaf82cee27731a459de950c

File Format: Update Package for MS Windows 32-Bit
File Name: SAS-Drive_Firmware_2XY5D_WN32_TS27_A00.EXE
File Size: 9.03 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
222c81b41ab5e566b85822a5af37b39c
SHA1:
5e36ad94ed2703d4ed824861fb7a8df35bf962a1
SHA-256:
1dd79c299549de041a55e3861674d378efbdb4632eddb2538b170ee5d01d1558

File Format: Update Package for Red Hat Linux
File Name: SAS-Drive_Firmware_2XY5D_LN_TS27_A00.BIN
File Size: 6.48 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
1bd876769959c4695a96a7ec919d586e
SHA1:
6c8a34ae6d315948a40c0100d0b134f8bbcabef5
SHA-256:
964a53cc6862302c263392fe4b3a7b5a83d8e094b3087c798fc35c0080e91eaa

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.

This update will run on drives remaining in a RAID set that is in a Offline state.

There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Suse Linux ES 10
Windows Server 2012
Red Hat® Ent Linux 5.2
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 7
Red Hat® Ent Linux 5
Windows Server 2012 R2
Windows Server 2008 x86
Windows Server 2008 R2
Windows Server 2016
C2075 Tesla GPU - 6GB DDR5
FGA,PWREDG R630,BTO
FGA,PWREDG R630,BTP
FGA,PWREDG R720,BTP
FGA,PWREDG R730,BTO
FGA,PWREDG R730,BTP
FGA,PWREDG R730XD,BTO
FGA,PWREDG R730XD,BTP
FGA,PWREDG T630,BTO
FGA,PWREDG T630,BTP
FHC,PH2A09D
FHC,PH2A10D
FHC,PH6029D
FHC,PH6177D
FHC,PH7113A
INFO,PQM,PERC,8.1.1V
SEAGATE THUNDERBOLT 2.5 1.8TB 10K SAS 512E
SWB,DIAG,MZR,SV,4217A4
SWB,DIAG,WPEPR,FCTRY,6030A1
SWB,OS,VMW,DEV,VTCTR,5.0U1
SWB,OS,VMW,DEV,VTCTR,5.0U2
SWB,OS,VMW,ESX4.1U2,ISO
SWB,OS,VMW,ESX4.1U3,ISO
SWB,OS,VMW,ESXI4.1U3,ISO
SWB,OS,VMW,ESXI5.0U1,ISO
SWB,OS,VMW,ESXI5.0U2,ISO
SWB,OS,VMW,ESXI5.1,ISO
SWB,OS,VMW,VTCTR,4.1U2
SWB,OS,VMW,VTCTR,4.1U3
SWB,SWB,OS,R220000
SWB,SWB,OS,R220001
SWB,SWB,OS,R220010
SWB,SWB,OS,R220012
SWB,SWB,OS,R220013
SWB,SWB,OS,R220014
SWB,SWB,OS,R220138
SWB,SWB,OS,R248703
SWB,SWB,OS,R248706
SWB,SWB,OS,R248719
SWB,SWB,OS,R248724
1. Click the 'Download Now' link to download the file.
2. When the File Download window appears, click 'Save' to save the file to your hard drive.

Installation

1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.

Drivers help and tutorials