PERC H965i Front Controller Firmware Version 8.14.0.0.18-14
Restart requiredInstalledThis file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This release updates the firmware residing on H965i Front controllers to package 8.14.0.0.18-14
Recommended
Check compatibility
Enter your Dell Service Tag or model
Want to look up your product? Enter a product identifier.Show me how
No results found.We couldn't find anything for your search. Please modify your search to enter a service tag (B959FS3) or model (Latitude 5540) and try again.
This driver is not compatible
This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.
Sign in to Windows as an admin to use automatic scan. If your're already signed in as an admin and seeing this message, please reboot.Your system is managed by your IT admin and features might be limited.
Find more updates. Use SupportAssist to find all the latest driver updates for your device.
Fixes & Enhancements
Fixes: ==== Fixed an issue where after a firmware update the PERC/HBA controller may not be detected on subsequent system resets. Fixed controller Fault 2656 seen while reprovisioning a SAS SED drive Fixed inability to perform VD Blink and Unblink operation from management application Fixed issue where Enclosure vendor ID and FW revision not listing in HII for external enclosures Enhancements: ============ Improved CBB Retry logic in FW to prevent firmware assert behaviors Enhanced efficiency in snapdump generation in HBA controllers Improved Backplane Topology Error Handling
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update. Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
################################################################ Important Information for Update Packages for Microsoft Windows ################################################################ * Do not run other applications while executing Update Packages. * Do not run storage controller update packages if the controller is in use by other applications. * The firmware upgrade may fail if any of the RAID controllers in the system are performing an I/O background task (that is, consistency check, background initialization, rebuild, or reconstruction). Allow the background task to complete before attempting to upgrade the firmware. Patrol Read tasks will not affect a firmware upgrade.
################################################################ Important Information for Update Packages for Linux ################################################################ * Do not run other applications while executing Update Packages. * If the following error occurs, "Error while loading shared libraries: libstdc++.so.5: cannot open shared object file: No such file or directory", you must install the compatibility libraries from "www.redhat.com" or from the Red Hat CD. To install the compatibility libraries, use the following command: "RPM -ih compat-libstdc++-33-3.2.3-47.3.i386.rpm" * When Update Packages stop abruptly due to a power outage or abnormal termination, perform the following steps: - Remove the lock file. Type the following command: rm -f /var/lock/.spsetup - Run the Update Package again to reapply the update. * Do not run storage controller update packages if the controller is in use by other applications. The firmware upgrade may fail if any of the RAID controllers in the system are performing an I/O background task (that is, consistency check, background initialization, rebuild, or reconstruction). Allow the background task to complete before attempting to upgrade the firmware. Patrol Read tasks will not affect a firmware upgrade. * Linux systems running one or more applications that interact with SCSI devices in certain ways are known to cause a kernel panic situation. Therefore, it is recommended that you stop Server Administrator and its Storage Management Service before running storage controller firmware update packages.
To stop the Dell OpenManage(TM) Server Administrator service, run "omconfig system webserver action=stop" To start the Server Administrator service, run "omconfig system webserver action=start" To stop the Server Administrator Storage Management Service, run "/etc/init.d/dataeng stop" To start the Server Administrator Storage Management Service, run "/etc/init.d/dataeng start"
########################### Enablement Inbox OS Drivers ########################### Enablement inbox drivers have been added to some OSes for initial launch of PERC12 controllers. These drivers are for OS install only and have limited performance and controller management functionality. Management Applications such as PERCCLI2 and Open Manage will not work with these drivers. Enablement drivers can be identified with version numbers "0.255.xxx.xxx" or "3.xxx.xxx.xxx". Driver version "8.xxx.xxx.xxx" should be installed as soon as possible or applied during OS install to enable full performance and management functionality of PERC12 controllers.
############################ Windows 2022 Inbox OS Driver ############################ The enablement driver "3.0.71.90" for Windows 2022 has known issues with Multi-CPU (2/4 CPU) and large core count CPU configurations that can cause OS to crash when loading the driver. It is recommended to install the latest "8.xxx.xxx.xxx" driver during OS install or as soon as possible after the install. If facing issues with crashes during OS installation it is recommended to disable Logical Processors and reduce CPU core count to 16 or less cores per CPU from the HII BIOS/UEFI settings menu. After installing the latest "8.xxx.xxx.xxx" PERC driver these set
Performing the Firmware Upgrade =================================== Update the firmware version to this version using preferred method below (Windows DUP, Linux DUP).
Windows Update Package: Download 1. From http://www.dell.com/support/home, download the update package and save it to your local hard drive.
Installation 1. Browse to the location where you downloaded the file and double-click the new file. 2. Read over the release information presented in the dialog window. 3. Download and install any prerequisites identified in the dialog window before proceeding. 4. Click the Install button. 5. Follow the remaining prompts to perform the update.
Linux Update Package: Download 1. From http://www.dell.com/support/home, download the update package and save it to your local hard drive.
Installation 1. Read over the release information presented by executing the "./SAS-NON-RAID_Firmware_XXXXX_LN_XXXXX.BIN --version" command from the shell. 2. Download and install any prerequisites identified in the above step before proceeding. 3. Run the update by executing "./SAS-NON-RAID_Firmware_XXXXX_LN_XXXXX.BIN" from the shell. 4. Follow the remaining prompts to perform the update.
IDRAC/LC 1. Download the Windows DUP Executable from http://www.dell.com/support/home 2. Upload DUP to IDRAC or LC 3. Submit job and reboot the system
PERCcli2 Note that PERCcli requires administrator privileges to run
1. Download the DUP from http://www.dell.com/support/home to a local system 2. Extract the Payload files from the DUP Extracted DUP > Common > Payload 3. Download and install the latest PERCCLI2 version to your server if not already installed 4. Copy the DUP payload files to your server 5. Navigate to PERCCLI2 folder Windows - folder with perccli2.exe Linux - /opt/Megaraid/perccli2 ESXi 7.0 U3 VMware - /opt/lsi/perccli2 ESXi 8.0 U2 VMware - /opt/perccli2/bin 6. Install the Firmware to your controller with the below command perccli /c download file= \Path To\.rom ESXi 8.0 U2 esxcli perccli2 controller download firmware -i c -z 0 -f \Path To\.rom -a online (0 - controller index no.)
Note: Online activation doesnt require reboot of the server