Download Files
File Format: This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation.
File Name: 9460_FW_MR7.5point3_ZPE.exe
File size: 9.68 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: 55cc3cdefad457365625a0c62611cfcd
SHA1: 9e54fda35a44ee92163f2ca4c85369f7312ad143
SHA-256: 5f88ed324259c9f20fd91a5ce14df945377deff9b88567aaa5523e495e4544d1
Supported Operating Systems
Installation instructions
Download the EXE file and extract it to a folder and follow the readme file within.
-------------------------------------------------------------------------------
Running the Storcli tool:
-------------------------------------------------------------------------------
For UEFI: run the storcli.efi from the UEFI shell
For windows 32 bit: use storcli.exe from a command prompt that is opened
using "run as administrator" option.
For windows 64 bit: use storcli64.exe from a command prompt that is opened
using "run as administrator" option.
-------------------------------------------------------------------------------
Updating the FW:
-------------------------------------------------------------------------------
For UEFI, use the following command from UEFI shell and reboot after the command completion
- storcli.efi /c0 download file = 9460-16i_nopad.rom
For Windows, Use the following command from command prompt that administrator
privileges and reboot after the command completion:
- storcli.exe /c0 download file = 9460-16i_nopad.rom (or)
- storcli64.exe /c0 download file = 9460-16i_nopad.rom
NOTE: If you have more than one controllers in your system, repeat this step but update /c0 to
/c1, /c2 and so on.
-------------------------------------------------------------------------------
Enabling NVME profile
-------------------------------------------------------------------------------
To change the card to NVMe profile, use the following command:
- UEFI: storcli.efi /c0 set profile profileid=11
- Winx86: storcli.exe /c0 set profile profileid=11
- Winx64: storcli64.exe /c0 set profile profileid=11
To change it back to SAS/SATA profile, use the following command:
- UEFI: storcli.efi /c0 set profile profileid=10
- Winx86: storcli.exe /c0 set profile profileid=10
- Winx64: storcli64.exe /c0 set profile profileid=10
To check the current profile:
- UEFI: storcli.efi /c0 show profile
- Winx86: storcli.exe /c0 show profile
- Winx64: storcli64.exe /c0 show profile
NOTE: With this release, either NVMe or SAS/SATA profile can be used at a
time. Both can not be used simultaneously.
-------------------------------------------------------------------------------
Applies to
9460-16i Storage Controller for Precision Workstations
MegaRAID SAS 9460-16i