Dell Networking N2000 Series, Firmware Version 6.5.3.3
Restart requiredInstalledThis file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
If N2000 series switch has an earlier version of firmware (6.0.0.7 or 6.0.0.8 or 6.0.1.3), upgrade switch to the latest version of firmware 6.5.3.3 as it contains multiple bug fixes.
New CPLD version 20 is available in release 6.5.1.1 and later (6.5.3.3) for both N3000 and N2000 Series switches. After upgrading the switches to FW version 6.5.1.1 and later (6.5.3.3), the CPLD can be updated to version 20 from CLI using the command - "update cpld". To update CPLD on stack members, run - 'update cpld ' command from stack master. Please DO NOT power-cycle the switch when CPLD update is in progress. After CPLD update is complete, the switch will reset on it's own. Verify CPLD Version with the command - 'show version' from CLI after switch boot-up completes.
****Below information is applicable ONLY for N2000/N3000 switches upgraded to 6.5.3.3 and CPLD Version 15 or 17 or 20 and attempt to downgrade to any prior FW version****
Downgrading N3000 and N2000 Series switches from firmware version 6.5.3.3 with the updated CPLD version 15 or 17 or 20 (Verify CPLD Version with the command “show version” from CLI) to any prior 6.x.x.x version can ONLY be done by downgrading via interim FW version B.6.3.2(N3000_N2000vB.6.3.2.stk) attached to zip file.
With interim FW image version B.6.3.2 running, the switches should be downgraded to CPLD version 13 first before downgrading to any 6.x.x.x version. Please follow the instructions documented in the “Firmware Downgrade” section of "Upgrading Dell EMC Networking N2000 Series Switches From Version 6.x.x.x to 6.5.3.3" procedure.
Please refer to the Release Notes for fixes and enhancements available in this release. "Release Notes" are included in the zip file - "Dell_EMC_Networking_6.5.3.3_6.5.3.33_Release_Notes(N1500_N2000_N3000_N3000E-ON_N4000_PC8100)".pdf"
Recommended
Check compatibility
Enter your Dell Service Tag or model
Want to look up your product? Enter a product identifier.Show me how
No results found.We couldn't find anything for your search. Please modify your search to enter a service tag (B959FS3) or model (Latitude 5540) and try again.
This driver is not compatible
This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.
Sign in to Windows as an admin to use automatic scan. If your're already signed in as an admin and seeing this message, please reboot.Your system is managed by your IT admin and features might be limited.
Find more updates. Use SupportAssist to find all the latest driver updates for your device.
Fixes & Enhancements
Fixes: FIELD-3327/CS6466035-SNMP table 1.3.6.1.2.1.17.7.1.2.2 OID returns unexpected character. FIELD-3333/CS6520532-Rebooting switch after config 8+ ACL lead to ports in DETACH state FIELD-3190/CS6234512-SSH using Public Key authentication fails FIELD-3299/FIELD-3372/CS6369121-Stack master crash with "nim_t" task periodically FIELD-3349/CS6620243-Security Check reported TCP Timestamp & Weak Signature Algorithm Vulnerabilities FIELD-3176/CS6078844-Stack Master becomes unstable with CPU timeouts causing management interruptions and authentication issues
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file format consists of an archive of files that may be decompressed to a directory on the hard drive. The installation can then be done from that directory.
Fixes: FIELD-3327/CS6466035-SNMP table 1.3.6.1.2.1.17.7.1.2.2 OID returns unexpected character. FIELD-3333/CS6520532-Rebooting switch after config 8+ ACL lead to ports in DETACH state FIELD-3190/CS6234512-SSH using Public Key authentication fails FIELD-3299/FIELD-3372/CS6369121-Stack master crash with "nim_t" task periodically FIELD-3349/CS6620243-Security Check reported TCP Timestamp & Weak Signature Algorithm Vulnerabilities FIELD-3176/CS6078844-Stack Master becomes unstable with CPU timeouts causing management interruptions and authentication issues
(1) Download the zip file - N2000v6.5.3.3.A42.zip (2) Extract the image file "N2000Stdv6.5.3.3.stk" from the zip file (3) Install the image to the switch by following the upgrade procedure "Upgrading Dell EMC Networking N2000 Series Switches From version 6.x.x.x to 6.5.3.3 Firmware.pdf" extracted from zip file.
Need help with network connection issues?
Find a solution in Dell's network troubleshooting guide