Delta 750W PSU (PN: 4V8KD,5RHVV,V1YJ6,G6W6K) Firmware Package

Restart required Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides the new firmware for power supplies and is supporting Delta 750W PSU.
(PN: 4V8KD,5RHVV,V1YJ6,G6W6K).
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

[For 4V8KD]
- Initial Release for 4V8KD.

[For 5RHVV,V1YJ6,G6W6K]
- Added support for Part Number: 4V8KD.
Read More

Version

00.30.C1, 00.30.C1

Release date

17 Jun 2020

Download Type

Firmware

Category

Power

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: Power_Firmware_N3K41_WN64_00.30.C1.EXE
File Size: 7.42 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
f285a6db0256958c47e6421b42eb03ff
SHA1:
1e6b88f0825126fcb56ade8888864509a0ecfed8
SHA-256:
93c4f05b44f56d00f8dcc3fb0088f0fae86d4849ade2835258d3739ad55ec8fe

File Format: A GnuPG file which contains a cryptographic signature
File Name: Power_Firmware_N3K41_LN_00.30.C1.BIN.sign
File Size: 226 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
5ece421bc70395118929a4ebcbbd9268
SHA1:
dfbd5237806e3a3f6109f04dc17aad53b2072f07
SHA-256:
ef667fe5cecd7300705ac742e65dc2f7f9ef518628fb0989e0b36e2ba34ef9ff

File Format: Update Package for MS Windows 32-Bit
File Name: Power_Firmware_N3K41_WN32_00.30.C1.EXE
File Size: 6.42 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
ca95fdc80c011cf77457441ff2c50465
SHA1:
6e5c7b3973a971bafcb0842e957b6d9e92f3f94a
SHA-256:
bf42c012b6993e93ac77af485bbeab2df40ed50d5498aa15cb2c612844f3a853

File Format: Update Package for Red Hat Linux
File Name: Power_Firmware_N3K41_LN_00.30.C1.BIN
File Size: 2.26 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
8f70981818a9f556788442874ac1ccb6
SHA1:
40f6485bdfdbf322c7fd0ba3dbf9500c89d7d77b
SHA-256:
b6ed9f677368dfde51df8c300c5f567616746e74fe6182361f4e6967e54f00e0

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.
Delta 750W PSU
PWR SPLY,750W,RDNT,13G,DELTA
PWR SPLY,750W,RDNT,13G,DELTA,V2
PWR SPLY,750W,RDNT,13G,DELTA,V3
PWR SPLY,750W,RDNT,13G,DELTA,V4
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the ".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.

Drivers help and tutorials