Dell EC MICRON 7400 NVMe M.2 RI FW 1.6.0 MTFDKBA800TFC,MTFDKBA480TDZ,MTFDKBG1T9TDZ,MTFDKBA960TDZ,MTFDKBG3T8TDZ,MTFDKBA960TDZ,MTFDKBA480TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG960TDZ,MTFDKBG3T8TDZ

Installed This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
Dell EC MICRON 7400 NVMe M.2 RI FW 1.6.0 MTFDKBA800TFC,MTFDKBA480TDZ,MTFDKBG1T9TDZ,MTFDKBA960TDZ,MTFDKBG3T8TDZ,MTFDKBA960TDZ,MTFDKBA480TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG960TDZ,MTFDKBG3T8TDZ
Recommended

Check compatibility

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:

- Multiple FW fixes and enhancements.
Read More

Version

1.6.0, A00

Release date

28 Oct 2024

Download Type

Firmware

Category

Solid State Storage

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: Express-Flash-PCIe-SSD_Firmware_N71F4_WN64_1.6.0_A00.EXE
File Size: 7.38 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
4cccae1ce99d2775b307427903734e0e
SHA1:
7d1d28a0e4ebf987fc096f08f51f1d81757effed
SHA-256:
c9739e4d67f20554e54535a5e643883eb887c9f922b33d9e9628c43f488da604

File Format: A GnuPG file which contains a cryptographic signature
File Name: Express-Flash-PCIe-SSD_Firmware_N71F4_LN64_1.6.0_A00.BIN.sign
File Size: 842 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
d6ac62d35d51812519d5c6ea4fb84044
SHA1:
3d01bcbf63f073f6f63d3268f0f9b671abcb8572
SHA-256:
844df30cc954f67bf6eae1b64bb5a0872b1dbad3664857a2abc5a4fff066a166

File Format: Update Package for Red Hat Linux
File Name: Express-Flash-PCIe-SSD_Firmware_N71F4_LN64_1.6.0_A00.BIN
File Size: 6.26 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
6caa08a21569eacfb263db99fdcf5b8c
SHA1:
355ca5f5502cd0052f96a03b2206c3723dac5031
SHA-256:
450c323522b5d0cc54153276b7124a67c7c0693dd2acf0539c8c085e754fe7dd

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.

This update will run on drives remaining in a RAID set that is in a Offline state.

There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.

A special process is recommended for upgrade/downgrade between versions 1.3.0 and any previous firmware. All versions of firmware prior to 1.3.0 have been found to include a bug in the reset phase of a firmware update with Commit Action 3 (AWOR - Activation WithOut Reset). If a firmware update with AWOR is performed simultaneously with IO to the drive, there is a possibility of a firmware assert. For drives that are running any firmware version prior to 1.3.0, it is recommended to quiesce IO to the drive and to use commit action 1 when updating firmware. The Update package provided will force commit action 1. With commit action 1, this will require a drive reset/power cycle for the FW to be activated.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Red Hat® Ent Linux 4
SuSE Linux ES 9
Suse Linux ES 9
Suse Linux ES 10
Linux
Windows Server 2012
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 7
Red Hat® Ent Linux 5
Red Hat® Enterprise Linux 8
Red Hat Enterprise Linux 9
Windows Storage Server 2012 R2
Novell SuSE Linux ES 10
SuSE Linux Desktop 11
SUSE Linux ES 12
SuSE Linux ES 15
Windows Server 2012 R2
Windows Server 2008 x86
Windows Server 2003
Windows Server 2019 LTSC
Windows Server 2022 LTSC
Windows Server 2025 LTSC
Windows Server 2008 R2
Windows Storage Server 2012
Windows Server 2016
Windows Server 2003 x64
Dell EC NVMe ISE 7400 MU M.2 80 800GB Model Number: MTFDKBA800TFC-1AZ1ZABDA Regulatory Model Number: MTFDKBA800TFC Vendor PN: MTFDKBA800TFC-1AZ1ZABDA
Dell EC NVMe ISE 7400 RI M.2 110 1920GB Model Number: MTFDKBG1T9TDZ-1AZ1ZABDA Regulatory Model Number: MTFDKBG1T9TDZ Vendor PN: MTFDKBG1T9TDZ-1AZ1ZABDA
Dell EC NVMe ISE 7400 RI M.2 110 3840GB Model Number: MTFDKBG3T8TDZ-1AZ1ZABDA Regulatory Model Number: MTFDKBG3T8TDZ Vendor PN: MTFDKBG3T8TDZ-1AZ1ZABDA
Dell EC NVMe ISE 7400 RI M.2 480GB Model Number: MTFDKBA480TDZ-1AZ1ZABDA Regulatory Model Number: MTFDKBA480TDZ Vendor PN: MTFDKBA480TDZ-1AZ1ZABDA
Dell EC NVMe ISE 7400 RI M.2 960GB Model Number: MTFDKBA960TDZ-1AZ1ZABDA Regulatory Model Number: MTFDKBA960TDZ Vendor PN: MTFDKBA960TDZ-1AZ1ZABDA
Dell EC NVMe OPAL 7400 RI M.2 480GB Model Number: MTFDKBA480TDZ-1AZ15ABDA Regulatory Model Number: MTFDKBA480TDZ Vendor PN: MTFDKBA480TDZ-1AZ15ABDA
Dell EC NVMe OPAL 7400 RI M.2 960GB Model Number: MTFDKBA960TDZ-1AZ15ABDA Regulatory Model Number: MTFDKBA960TDZ Vendor PN: MTFDKBA960TDZ-1AZ15ABDA
Dell Update Package instructions for Windows Dup:

1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.

Dell Update Package instructions for Linux DUP (RHEL/SLES/Ubuntu):

1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and run the update by executing
"./ NVMe_Firmware__LN__A00.BIN " from the shell.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions:

Download the latest GnuPG Signature of Dell Update Package from support.dell.com.

1. Browse to the location where you downloaded the file.
2. Read over the release information presented in the dialog window.
Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, NVMe_Firmware__LN__A00.BIN.sign.

Drivers help and tutorials