Download Files
File Format: Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
File Name: RAID_FRMW_WIN_R126663.EXE
File size: 2.44 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: AECB3793B8DB1E0823C6BB39F7428AB5
File Format: This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, then double-click it to unzip the set of files. Follow the instructions to complete the installation.
File Name: BR126663.exe
File size: 1.24 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: 1aaa78ef9bb99617d854025cfca73411
File Format: The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
File Name: RAID_FRMW_LX_R126663.BIN.sign
File size: 194 Bytes
To ensure the integrity of your download, please verify the checksum value.
MD5: 0FE89B81DFDB879EEE6098FCA5002D21
File Format: This file format contains plain text which can be viewed with a standard text editor.
File Name: perc4e-FWKB522A-A15.txt
File size: 9.09 KB
To ensure the integrity of your download, please verify the checksum value.
MD5: 5771b74860307bcbaa5439823f04c8b0
File Format: Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.<br /><b>Note:</b> Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
File Name: RAID_FRMW_LX_R126663.BIN
File size: 9.5 MB
To ensure the integrity of your download, please verify the checksum value.
MD5: 027F5CF54843A53B36E7FC730D0C6FBD
Fixes & Enhancements
Fixes: This release is URGENT if 1. applies, otherwise it is RECOMMENDED.
1. Fixed an issue that could cause a blue screen, file system error or system hang when using EVPD inquiry commands.
2. Fixed an issue where the write cache policy is reported incorrectly under rare circumstances.
Important Information
After installing this firmware and rebooting, a consistency check will automatically begin on RAID 5 and 50 virtual disks with 5 or more physical disks to ensure parity information is correct. The consistency check cannot be terminated and will resume at its last point following a reboot. This consistency check will appear as a Background Initialization but will only perform a consistency check with no data being modified. The consistency check runs in the background, allowing the virtual disks to remain accessible during the check. While this background check is designed to minimize performance impact, some degradation in performance may occur until the check is complete, especially under heavy I/O. If you have already updated to the firmware version "521X" and have run a consistency check, you do not need to update. This release contains the same firmware version with the addition of an automated, background consistency check.
Supported Operating Systems
Installation instructions
Custom Instructions for perc4e-FWKB522A-A15.txt:
Download the readme file to view information about this release.
Custom Instructions for BR126663.exe:
This program creates a bootable diskette to upgrade the firmware of the
controllers. You will need a formatted 3 1/2 inch floppy diskette for the
following procedure.
1) Download the file to a directory on your hard drive. The file downloaded is
a self extracting executable.
2) Insert a blank diskette into the system's diskette drive.
3) Double click on the file that you downloaded and follow the instructions on
the screen to extract the files to the diskette.
4) Insert the diskette into the system with the RAID controller for which you
want to update the firmware and boot the system.
5) Follow the instructions on the screen to update the firmware.
NOTICE: Pflash.exe will be executed automatically and will report existing code
level and prompt you to reconfirm before starting the firmware upgrade
process.
To perform this process in non-interactive mode please execute,
Pflash /?
and read about possible command line switches.
6) Remove the diskette and reboot the system.
Instructions for RAID_FRMW_WIN_R126663.EXE:
Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
Instructions for RAID_FRMW_LX_R126663.BIN:
Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.
Installation
1. Read over the release information presented by executing the ./RAID_FRMW_LX_R126663.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ./RAID_FRMW_LX_R126663.BIN from the shell.
4. Follow the remaining prompts to perform the update.
GnuPG Signature of Dell Update Package Instructions for RAID_FRMW_LX_R126663.BIN.sign:
Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.
Installation
1. Import the Dell public key. (You only need to do once on your system.)
2. Verify the Dell Update Package by using its signature file, RAID_FRMW_LX_R126663.BIN.sign