Dell Networking serie N2000, versión de firmware 6.2.1.6, A06
Reinicio requeridoInstaladaEste archivo se instaló automáticamente como parte de una actualización reciente. Si experimenta algún problema, puede descargarlo y reinstalarlo manualmente.
Es posible que el contenido de esta página se traduzca automáticamente. Para proporcionar comentarios, complete el formulario en la parte inferior de la página.
Este archivo se instaló automáticamente como parte de una actualización reciente. Si experimenta algún problema, puede descargarlo y reinstalarlo manualmente.
Both Dell Networking N2000 and N3000 Series switches share the same firmware image file (N3000_N2000v6.2.1.6.stk). If your N2000 series switch has an earlier version of firmware (6.0.0.7 or 6.0.0.8 or 6.0.1.3), upgrade your switch to the latest version of firmware 6.2.1.6 as it contains multiple bug fixes.
After upgrading the switch firmware version to 6.2.1.6, the boot code update is required on N2000 series switches via serial console if switch is running with the older boot code version. The latest boot code version available for N2000 series switches is “U-Boot SPL 2012.10-00078-g24e99ea (Jun 24 2014 - 16:41:18)"
Please refer to the Release Notes for fixes and enhancements available in this release. "Release Notes" are included in the zip file - "Dell Networking_6.2.1.6_Release_Notes".
Please follow firmware upgrade instructions included in the zip file - "Upgrading Dell Networking N3000_N2000 Series Switches From Version 6.x.x.x to 6.2.1.6 Firmware"
Recomendado
Comprobar compatibilidad
Ingrese los detalles del producto para ver la información más reciente del controlador para el sistema
Ingrese su modelo o etiqueta de servicio de Dell
¿Desea buscar su producto? Ingrese un identificador de producto.Mostrarme cómo
No se encontraron resultados. No pudimos encontrar ningún resultado para la búsqueda. Modifique la búsqueda para ingresar una etiqueta de servicio (B959FS3) o un modelo (Latitude 5540) y vuelva a intentarlo.
Este controlador no es compatible
Este controlador no se corresponde con el producto seleccionado. Elija otro producto para volver a ingresar los detalles del producto para este controlador o visite la página Soporte de productos para ver todos los controladores de un producto diferente.
Inicie sesión en Windows como administrador para utilizar el escaneo automático. Si ya inició sesión como administrador y ve este mensaje, reinicie el sistema.El administrador de TI administra el sistema y es posible que las funciones sean limitadas.
Encuentre más actualizaciones. Utilice SupportAssist para encontrar todas las actualizaciones de controladores más recientes para su dispositivo.
Correcciones y mejoras
New Features & Enhancements: -Added Port-Security Sticky-MAC feature -Added support configuration of AdvLinkMTU, and included option MTU in Router Advertisement Message -Kernel updates and SSL version upgrade to 1.0.1.m
Fixes: Case ID Summary 865050 - N2048P v6.1.2.4 VoIP phones assigned to wrong VLAN since the stack was upgraded to v6.1.1.7 878235 - Routing issue, null address in ARP table after VLAN manipulation 881612 - N2048 - 6.1.2.4: web timeout (HTTPS) does not depend on exce-timeout configuration 883154 - N2048P - 6.1.2.4: Stack master unit crashing issuing some 'show' CLIs 886897 - N30XX v6.1.2.4 Ports on VLAN with PVST/R-PVST disabled not learning MAC addresses after reboot 890563 - ARP resolution not happening for iSCSI traffic when iSCSI optimization is enabled 891874 - N2048 - 6.1.2.4: Switch not sending snmp trap notification for UP/DOWN status on loopback interfaces 890635 - N-Series - 6.1.2.4 - SNMP MIB Walk OID "1.3.6.1.4.1.674.10895.3000.1.2.100" returns URL http://0.0.0.0 896750 - N-Series - 6.1.2.4 - IPv6 connectivity failure after stack member failure on N4064F stack with Fluid FS 897308 - N-Series Port-Security VoIP/PC issue 903943 - N-Series - 6.2.0.5 - N3000 - Receive and transmit packets dropped > MTU counters increasing 907269 - N-Series - 6.2.0.5 - Add 1G SFP (PN# FTRJ1319P1BTL) transceiver support 813685 - UNH - IPv6 - N3000 - USGv6 Interoperability and Basic Conformance failures 873414 - UNH : Unconfigurations of MTU values using the command "no system jumbo mtu" does not take effect in the DUT, after the DUT is configured with some random mtu value in the range of 1298-9216. 913069 - UNH : OSPF neighbourship not coming up on the dauntless after stack initiate failover, with MTU configured as 1298 and OSPF interface configured with ignore-mtu. 913071 - UNH : No ICMPv6 Too Big message sent on the interface, when the packet arrived on an interfaces that has less MTU configured. 913074 - UNH : DUT must drop the packet that has multicast address whose scop field contains the reserved value 0 as per RFC4291,section 2.7(page 14), but the ipv6 mrouter table has the learned-entry. 913068 - UNH : DUT should forward the packet that has multicast address whose scop field contains the reserved value "F" as per RFC4291 of section 2.7(page 14), but the first ICMPv6 echo request packet is getting dropped 913078 - UNH : In USGv6 Basic Conformance, the tests failed showing the reason "The device under test does not generate an ICMPv6 Parameter Problem messages in response to invalid packets". 913077 - UNH : In USGv6 Basic Conformance, the tests failed showing the reason "The device under test does not generate an Echo Reply to packets containing Pad1 or PadN options.". 913072 - UNH : DUT has problem in configuring and propagating IPv6 parameter as per the "v6LC.2.2.7c" test mentioned in the UNH defect 901088 - Connection fd is corrupt sometimes in bgp neighbor connection list 913061 - Flash format optionis missing on N4000 Series Bootmenu. 906510 - Route loop in leaf-spine topology after bringing down the link between Leaf-1 and spine-2 913067 - 6.2: Allow period '.' in configuration of the hostname 876886 - N4064F - 6.1.2.4: ARP entries with 0000.0000.0000 mac-address 883154 - N2048P - 6.1.2.4: Stack master unit crashing issuing some 'show' CLIs 839620 - N4032F Static IP Routing Issue. 921285 - DFE should to be turned on for 10Gb copper ports on N4000 Series. 921287 - Hotswapping different modules on N4000 Series causes the switch to crash. 921322 - OSAPI semaphores don't work when two tasks are waiting on the same semaphore. 922468 - After save and reload sticky mode functionality is not properly working. 907697 - N20xx dot1x mac based authentication,clients behind phones can't forward traffic 920185 - N3000-6.2-Front 10G ports goes down when 10G SFP extension module is removed from the slot
Dell Technologies recomienda aplicar esta actualización durante su próximo ciclo de actualizaciones programadas. La actualización contiene cambios para mantener el estado general del sistema. Garantiza que el software del sistema permanezca actualizado y compatible con otros módulos del sistema (firmware, BIOS, controladores y software) y puede incluir otras funciones nuevas.
Formato de archivo:Extrae archivos directamente al disco local
File Name:N2000v6.2.1.6a06.zip
Tamaño del archivo:22.97 MB
Este es un archivo grande. La descarga puede tardar, dependiendo de la velocidad de conexión.
Descripción del formato:
Este formato de archivo consiste en un archivo de archivos que se pueden descomprimir a un directorio en el disco duro. La instalación puede realizarse desde ese directorio.
Please refer to the Release Notes for additional bug fixes and feature enhancements available in this release. "Release Notes" are included in the zip file - "Dell Networking_6.2.1.6_Release_Notes"
(1) Download the zip file - N2000v6.2.1.6a06.zip (2) Extract the image file "N3000_N2000v6.2.1.6.stk" from the zip file (3) Install the image to the switch by following the upgrade procedure "Upgrading Dell Networking N3000_N2000 Series Switches From Version 6.x.x.x to 6.2.1.6 Firmware.pdf" extracted from zip file.
Reboot will be required
¿Necesita ayuda con los problemas de conexiones de red?
Busque la solución en la guía de solución de problemas de red de Dell