Dell Networking N3000 Series, Firmware Version 6.5.2.9
Omstart krevesInstallertDenne filen ble automatisk installert som en del av en nylig oppdatering. Hvis du opplever problemer, kan du laste ned og installere på nytt manuelt.
Innholdet på denne siden kan ha blitt oversatt automatisk. Fyll ut skjemaet nederst på siden for å gi tilbakemelding.
Denne filen ble automatisk installert som en del av en nylig oppdatering. Hvis du opplever problemer, kan du laste ned og installere på nytt manuelt.
Dell EMC Networking N3000 series switches can mixed stack with N3132PX-ON switches of up to 8 units. Mixed stack of N3000 series Switches and N3132PX-ON switch support 1024 active VLANs configurable in the range 1-4093 and does not support MMRP/MVRP. Dell EMC Networking N3132PX-ON switches has an expansion slot to install optional stacking module with two mini-SAS stack ports. Dell EMC Networking N3000 Series switches are available with two fixed mini-SAS stack ports.
Administrators configuring mixed stack with N3000 Series switches and N3132PX-ON MUST follow the instructions documented in the "Upgrading Dell Networking N3132PX-ON Switches to Version 6.5.2.39(Advanced) or 6.5.2.9(AdvancedLite).pdf". It is strongly recommended to backup current switch configuration before forming mixed stacking.
New CPLD version 20 is available in release 6.5.1.1 and later (6.5.2.9) for both N3000 and N2000 Series switches. After upgrading the switches to FW v6.5.1.1 and later (6.5.2.9), the CPLD can be updated to version 20 from CLI using the command - 'update cpld'. To update CPLD on stack members, run - 'devshell cpldUpdate' command from serial console. Please DO NOT power-cycle the switch when CPLD update is in progress. After CPLD update completes, the switch will reset on its own.
**Below information is applicable ONLY for N2000/N3000 switches upgraded to 6.5.2.9 with CPLD Version 15 or 17 or 20 and attempt to downgrade to any prior FW version**
Downgrading N3000 and N2000 Series switches from firmware version 6.5.2.9 with the updated CPLD version 15 or 17 or 20 to any prior 6.x.x.x version can ONLY be done by downgrading via interim FW version B.6.3.2 or B.6.3.32 (N3000_N2000vB.6.3.2.stk or N3000_BGPvB.6.3.32.stk) attached to zip file. Please follow the instructions documented in the “Firmware Downgrade” section of "Upgrading Dell EMC Networking N3000 Series Switches From Version 6.x.x.x to 6.5.2.9" procedure.
Anbefalt
Sjekk kompatibilitet
Angi produktdetaljer for å vise den nyeste driverinformasjonen for systemet
Skriv inn Dell-service-ID-en eller -modellen
Ønsker du å finne produktet? Skriv inn en produktidentifikator.Vis meg hvordan
Finner ingen resultater. Vi finner ikke noe for søket ditt. Endre søket for å angi service-ID (B959FS3) eller modell (Latitude 5540), og prøv på nytt.
Denne driveren er ikke kompatibel
Denne driveren er ikke gjeldende for det valgte produktet. Velg et annet produkt for å angi produktopplysningene dine for denne driveren på nytt, eller gå til siden for produktstøtte for å vise alle drivere for et annet produkt.
Logg på Windows som administrator for å bruke automatisk skanning. Hvis du allerede er logget på som administrator og ser denne meldingen, må du starte maskinen på nytt.Systemet ditt blir administrert av IT-administratoren, og funksjonene kan være begrenset.
Finn flere oppdateringer. Bruk SupportAssist for å finne alle de nyeste driveroppdateringene for enheten din.
Feilrettinger og forbedringer
Fixes: FIELD-2846,FIELD-2851,FIELD-2852,CS4789696-Under voltage detection warning and log shows VIN=1.25V FIELD-2868,CS4971583-PSU failure logs FIELD-2995,FIELD-2949,FIELD-3072,CS5237423-Switch goes thermal shutdown FIELD-2989,CS5185018-Switch reboots on its own without crash log. FIELD-2980,CS5186162-SNMPSET MIB OID .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.2.9.1.4. fails with commitFailed FIELD-3002,CS5241581-Switch crashes with 'hapiMcAsyncTask' task. FIELD-2972,CS5158072-ARP responses dropped (not reaching CPU) after ARP timeout expires for end hosts FIELD-3006,CS5178704-Out of memory causing SSH failure, crypto-key generate failure and switch goes unresponsive after write. FIELD-3034,CS5373126-Failed to remove IPSG binding for IP on interface from hardware. Internal-Improve packet RX processing on stackable switch platforms. FIELD-3031,CS5327765-Standalone switch crashes with 'osapiTimer' task. CS5541938-MAC Address movement logging and traps FIELD-3096,CS5754107-IP Phone got session reset every hour and cause phone service interruption when dot1x reauthentication enabled(default reauth = 3600) FIELD-3104,CS5837205-N2048P/N3132-DHCP Client fails to get IP address assigned with dot1x mac-based authenticated port
Dell Technologies anbefaler at du installerer denne oppdateringen ved neste planlagte oppdatering. Oppdateringen inneholder endringer for å opprettholde den generelle systemtilstanden. Det sikrer at systemprogramvaren forblir oppdatert og kompatibel med andre systemmoduler (fastvare, BIOS, drivere og programvare) og kan inkludere andre nye funksjoner.
Fixes: FIELD-2846,FIELD-2851,FIELD-2852,CS4789696-Under voltage detection warning and log shows VIN=1.25V FIELD-2868,CS4971583-PSU failure logs FIELD-2995,FIELD-2949,FIELD-3072,CS5237423-Switch goes thermal shutdown FIELD-2989,CS5185018-Switch reboots on its own without crash log. FIELD-2980,CS5186162-SNMPSET MIB OID .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.1.2.9.1.4. fails with commitFailed FIELD-3002,CS5241581-Switch crashes with 'hapiMcAsyncTask' task. FIELD-2972,CS5158072-ARP responses dropped (not reaching CPU) after ARP timeout expires for end hosts FIELD-3006,CS5178704-Out of memory causing SSH failure, crypto-key generate failure and switch goes unresponsive after write. FIELD-3034,CS5373126-Failed to remove IPSG binding for IP on interface from hardware. Internal-Improve packet RX processing on stackable switch platforms. FIELD-3031,CS5327765-Standalone switch crashes with 'osapiTimer' task. CS5541938-MAC Address movement logging and traps FIELD-3096,CS5754107-IP Phone got session reset every hour and cause phone service interruption when dot1x reauthentication enabled(default reauth = 3600) FIELD-3104,CS5837205-N2048P/N3132-DHCP Client fails to get IP address assigned with dot1x mac-based authenticated port
(1) Download the zip file - N3000v6.5.2.9.A39.zip (2) Extract the image file "N3000AdvLitev6.5.2.9.stk" from the zip file (3) Install the image to the switch by following the upgrade procedure "Upgrading Dell EMC Networking N3000 Series Switches From Version 6.x.x.x to 6.5.2.9 Firmware.pdf" extracted from zip file.
Trenger du hjelp med problemer med nettverkstilkoblingen?
Finn en løsning i Dells feilsøkingsveiledning for nettverk