Fixes:
The following problems are reported in earlier releases of Server Administrator and have been corrected in this release:
- Connection service crash in Windows OS after enabling/disabling session timeout in OMSA.
- PCIeSSD Drives are showing up in the OMSA slots view instead of the Brdige Card.
- NIC and TEAMED NIC association corrected.
- Add attacheement failure fixed on Safari 8.0
- Mellanox card doesnt display all the interface names (ports) in OMSA after we reboot server.
- Omacs crash if new network interfaces appear.
- Broadcom NXII duplicate nic info is showing in OMSA gui after flashing the driver.
- Command log message is not generated for SSL Protocol setting in GUI.
- OMSA reporting Degraded for Unknown Reason status under Hardware Performance.
- OMSA spawning kipmi0 thread even on 12G/13G where IPMI should use interrupts.
- NVMe:Slot occupancy report was displaying single backplane ID and backplane name in GUI and CLI.
- Concatenated option is observed in RAID LEVEL during VD creation in stpe of OMSS.
- OMSS GUI Display improper PD list for successfull RAID to NON RAID conversion on ESXi 5.5.
- After enclosure hot plug fromSAS12Gbps HBA-OMSA showing Enclosure presence.
- OMSA GUI shows BACKPLANE info for T130 server; but T130 is a CABLED HDD config.
- Unassign GHS shows up for PCIe SSD NVMe Disks.
- NVMe PCIeSSD drivers are not sensing in OMSS on RHEL 7.2
- RAID Level Migration from RAID1 to RAID10 without adding any Physical Disks in OMSS GUI with PERC9.2 FW
Enhancements:
The release highlights of Server Administrator are:
1. Support for following server:
- PowerEdge Server R830
2. Support for the following Operating Systems:
- Novell SUSE Linux Enterprise Server 12 Service Pack 1.
- Red hat Enterprise Linux 7.2
NOTE: Citrix XenServer Operating System support has been dropped for Server Administrator and Storage Management.
3. Support for following Web Browser:
- Google Chrome Version 45
- Mozilla Firefox Version 40
4.Support for following features:
- GP-GPU card enablement on C4130
- SNMP Test Trap Button feature on all Linux Operating System.
- Notifying presence of iDRAC on Dell Servers.
5. Added new functionalities inStorage Management:
- Support for 2.5-inch 4KB SATA drivers on PERC 9 family of hardware controllers.
- Support for rear SATA on PowerEdge R730XD connected to software RAID S130 controller.
- Support for PMC SAS Expander on PowerEdge R730.
- Support for Samsung PM1725 NVMe device.
- Support for flexible backplane zoning functionality on backplanes with 24 slots - PowerEdge R630 and PowerEdge R730XD.
- Support for setting Disk Cache Policy at Physical Disk and Virtual Disk level on software RAID S130 controller.
- Support for setting Non-RAID disk cache policy on PERC9 controllers.
- Support for HBA H330 Adapter/Mini Controller.
NOTE: For then list of supported Operating Systems and Dell Servers, see the Dell Systems Software Support Matrix in the required version on OpenManage Software at dell.com/openmanagemanuals.
NOTE: For more information about the features introduced in this release, see the Server Administrator contect-sensitve online help.