下載檔案
檔案格式: 此檔案內含已壓縮的檔案集。將檔案下載到硬碟上的資料夾,然後執行 (按兩下) 以解壓縮該檔案集。請依照指示完成安裝。
檔案名稱: 9440_FW_MR7.8.1_ZPE.exe
檔案大小: 7.29 MB
為了確保下載的完整性,請驗證總和檢查值。
MD5: b68d005ea5a681c54a14d8fc49d5260f
SHA1: d8163969cfddc94309bbcb99f9ca2d7865100d0d
SHA-256: e098743fa38eab8d4fb8500f5a195d6fdb198c8c069eb25407076560b2173d5b
修復及強化
- Added support for NVMe passthrough in UEFI mode.
安裝指示
Download and Extract
1. Click Download to download the file.
2. When the File Download window is displayed, click Save to save the file to your hard drive.
3. Extract the file from the .zip.
4. Follow the instructions in the Readme.txt within the .zip file.
Installation
UEFI
1. Run the storcli.efi from the UEFI shell.
2. To update, use the following command in the UEFI shell and reboot the system after completion:
storcli.efi /c0 download file = 9441-8i_nopad.rom
3. Repeat the step if you have more than one controller in your system by updating /c0 to /c1, and so on.
Windows 32-bit and 64-bit
1. Open an elevated command prompt window by using the Run as administrator option.
2. For 32-bit systems, run the storcli.exe and for 64-bit systems, run storcli64.exe.
3. To update, run the following command and reboot the system after completion:
For Windows 32-bit - storcli.exe /c0 download file = 9441-8i_nopad.rom
For Windows 64-bit - storcli64.exe /c0 download file = 9441-8i_nopad.rom
4. Repeat the step if you have more than one controller in your system by updating /c0 to /c1, /c2, and so on.
Enabling the NVMe profile
Note: ProfileID=11 is used only NVMe and ProfileID=13 is used for Mixed mode to use SAS/SATA and NVMe simultaneously.
UEFI
1. Run the following command to change the card to NVMe profile:
storcli.efi /c0 set ProfileID=11
2. Run the following command to change the card back to SAS/SATA profile:
storcli.efi /c0 set ProfileID=10
3. Run the following command to check the profile:
storcli.efi /c0 show profile
Windows 32-bit
1. Run the following command to change the card to NVMe profile:
storcli.exe /c0 set ProfileID=11
2. Run the following command to change the card back to SAS/SATA profile:
storcli.exe /c0 set ProfileID=10
3. Run the following command to check the profile:
storcli.exe /c0 show profile
Windows 64-bit
1. Run the following command to change the card to NVMe profile:
storcli64.exe /c0 set ProfileID=11
2. Run the following command to change the card back to SAS/SATA profile:
storcli64.exe /c0 set ProfileID=10
3. Run the following command to check the profile:
storcli64.exe /c0 show profile
適用於
9440-8i Storage Controller for Precision Workstations
MegaRAID SAS 9440-8i