Seagate PB53 for model number(s) ST8000NM0205..
已安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This release contains firmware version PB53 for Seagate drives. Vendor model numbers ST8000NM0205..
建議
尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。
修復及強化
Initial release
閱讀更多繁體中文版
PB53, A00
發佈日期
19 6月 2017
下載類型
韌體
類別
儲存
重要性
建議Dell Technologies 建議您在下一個排定的更新週期套用此更新。此更新包含的變更可維持整體的系統健全狀況。此更新可確保系統軟體保持在最新狀態並與其他系統模組 (韌體、BIOS、驅動程式及軟體) 相容,並且可能包含其他新功能。
檔案格式: 適用於 MS Windows (64 位元) 的更新套件。
檔案名稱: Serial-ATA_Firmware_MR6RH_WN64_PB53_A00_01.EXE
檔案大小: 12.19 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
如果 Dell 更新套件為原生 Microsoft Windows 64 位元格式,則不需要在 Microsoft Windows Server 安裝 Microsoft WOW64。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
3af86607752441061fba620c229fd79c
SHA1:
4e9e0628c891a3c545d83e14aaca05d29c2cd64f
SHA-256:
a4951c8973ce52b7ebf10ba60c45e915975959cfeec0cb2c79956f7d78a63f74
檔案格式: 包含密碼編譯簽章的 GnuPG 檔案
檔案名稱: Serial-ATA_Firmware_MR6RH_LN64_PB53_A00_01.BIN.sign
檔案大小: 226 Bytes
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
您可以使用適用於 Red Hat Linux 更新套件的 GnuPG 簽章,在相關聯的 Red Hat Linux 更新套件中驗證 Dell 的身分。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
c45a415d31ca9b7e210cb72912e73224
SHA1:
97ae5f9339335f8da0b5df1827bc504fc9493497
SHA-256:
c63a2867db4c9aa4d85bf879a3830cfb4fbe185a3d25b97d7c3b7a60cdbf3f99
檔案格式: 適用於 MS Windows (32 位元) 的更新套件
檔案名稱: Serial-ATA_Firmware_MR6RH_WN32_PB53_A00.EXE
檔案大小: 11.07 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
Microsoft Windows 32 位元格式的 Dell 更新套件 (DUP) 經過精心設計,可在 Microsoft Windows 64 位元作業系統上執行。Microsoft Windows 64 位元格式的 Dell 更新套件 (DUP) 只能在 Microsoft Windows 64 位元作業系統上執行。選擇裝置驅動程式更新時,請務必選擇適用您作業系統的更新。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
5c2fe0cfd989f73e21bbaaefac46242d
SHA1:
a82a9e4022fd509c46b1f41cd5a7f07fd4346af6
SHA-256:
080f82f0610d52961a00b11dd58996ec79ccffabc8428923b0c7ad79bab62a2d
檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: Serial-ATA_Firmware_MR6RH_LN64_PB53_A00_01.BIN
檔案大小: 7.77 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
de315f59eec7d035cb4d18edd7bbbd60
SHA1:
468d8b85805e349ffea866b3c085ff51f9de5c59
SHA-256:
efd45c9782337b94dbafca620a4b14971ac21c9bd39a1932e4e63bcd888a117a
當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.
This update will run on drives remaining in a RAID set that is in a Offline state.
There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.
This update will run on drives remaining in a RAID set that is in a Offline state.
There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Suse Linux ES 10
Windows Server 2012
不適用
Red Hat® Enterprise Linux 5.2
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 7
Red Hat® Enterprise Linux 5
Windows Server 2012 R2
Windows Server 2008 x86
Windows Server 2008 R2
Windows Server 2016
Seagate Makara Plus 6Gbps SATA 3.5 7.2K 512e ISE
Model No: ST8000NM0205-2FF112
Vendor PN: 2FF112-136
Regulatory Model No: STR008
1. Click the 'Download Now' link to download the file.
2. When the File Download window appears, click 'Save' to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
2. When the File Download window appears, click 'Save' to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.